Tumor dose enhancement by nanoparticles during high dose rate 192 Ir brachytherapy

被引:18
|
作者
Zabihzadeh, Mansour [1 ,2 ]
Arefian, Sahar [1 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Sch Med, Dept Med Phys, Golestan Blvd, Ahvaz 6135733118, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Golestan Hosp, Dept Radiotherapy & Radiat Oncol, Ahvaz 6135733118, Iran
关键词
Brachytherapy; dose enhancement factor; Monte Carlo simulation; nanoparticles; photoelectric interaction; GOLD NANOPARTICLES; MONTE-CARLO; VASCULAR-PERMEABILITY; IR-192; SOURCE; SOLID TUMOR; RADIATION; DOSIMETRY; RADIOTHERAPY; CANCER; FEASIBILITY;
D O I
10.4103/0973-1482.153668
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims and Objectives: The present study aims to evaluate and compare the dose enhancement factor (DEF) of tumor injected with different nanoparticles (NPs) around high dose rate (HDR) (192) Ir brachytherapy source. Materials and Methods: Monte Carlo calculations were performed with MCNPX code to determine the DEF caused by in tumor injected with (79) Au, (64) Gd, (26) Fe, and (22) Ti NPs during HDR (192) Ir brachytherapy. The uniform and non-uniform distribution of NPs within tumor was modeled with simple NPs-water mixture, and realistic nano-scale-lattice model. Furthermore, a margin of (79) Au and (64) Gd NPs was implemented around the tumor volume. Results: The increased dose caused by uniformly distributed (79) Au and (64) Gd NPs with 7, 18, and 30 mgr/gr concentrations was 4.7%, 11.8%, 19.4%, and 3.3%, 8.3%, and 18.6%, respectively. For non-uniform distribution, it was 0.4%, 1.2%, 1.9%, and 0.2%, 0.7%, and 1.2%, respectively. Increased tumor dose due to (26) Fe and (22) Ti was not significant. The peripheral-healthy tissue dose as margin with 2, 5, and 8.5 mgr/gr of (79) Au and (64) Gd increased by 1.3%, 3.6%, 6.5%, and 1.1%, 2.5%, and 4.2%, respectively. Increase the radial depth of tumor (from 1.5 to 5 cm) increase DEF (up to 22.3%). The nano-lattice model underestimated the DEF up to 4% and 3.6% for 79Au and (64) Gd NPs, respectively. Conclusion: Injecting of high-Z gold NPs into tumor increases the absorbed dose of tumor irradiated with (192) Ir HDR brachytherapy source. Size, geometry, concentration, and distribution model of NPs and tumor depth are crucial factors to accurately estimate the DEF.
引用
收藏
页码:752 / 759
页数:8
相关论文
共 50 条
  • [1] Transit dose of an Ir-192 high dose rate brachytherapy stepping source
    Wong, TPY
    Fernando, W
    Johnston, PN
    Bubb, IF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 323 - 331
  • [2] High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
    Nikoofar, Alireza
    Hoseinpour, Zohreh
    Mahdavi, Seied Rabi
    Hasanzadeh, Hadi
    Tavirani, Mostafa Rezaei
    IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (03)
  • [3] Verification of high dose rate 192Ir source position during brachytherapy treatment
    Batic, M.
    Burger, J.
    Cindro, V.
    Kramberger, G.
    Mandic, I.
    Mikuz, M.
    Studen, A.
    Zavrtanik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 206 - 208
  • [4] Optimizing Gold Nanoparticles for Radiation Dose Enhancement in Ir-192 HDR Brachytherapy
    Gao, J.
    Zhang, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E823 - E823
  • [5] A technique for calibrating a high dose rate 192Ir brachytherapy source
    Fourie, O. L.
    Crabtree, T. G.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2012, 35 (01) : 85 - 92
  • [6] Quality control of 192Ir High Dose Rate Brachytherapy sources
    Pereira, A
    Pirraco, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S136 - S137
  • [7] A technique for calibrating a high dose rate 192Ir brachytherapy source
    O. L. Fourie
    T. G. Crabtree
    Australasian Physical & Engineering Sciences in Medicine, 2012, 35 : 85 - 92
  • [8] High dose rate 192Ir afterloading brachytherapy for cancer of the vagina
    Kushner, DM
    Fleming, PA
    Kennedy, AW
    Wilkinson, DA
    Lee, E
    Saffle, PA
    BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (910): : 719 - 725
  • [9] A novel absorbed dose standard for the calibration of 192Ir sources used in high dose rate brachytherapy
    D'Arienzo, M.
    Guerra, A. S.
    Loreti, S.
    Caporali, C.
    Pimpinella, M.
    Bolzan, C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S146 - S147
  • [10] A microDiamondfor determination of absorbed dose around high-dose-rate 192Ir brachytherapy sources
    Kaveckyte, V.
    Malusek, A.
    Benmaklouf, H.
    Carlsson, G. Alm
    Tedgren, A. Carlsson
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S407 - S407