A NEW METHOD FOR THE COMPENSATION OF COAXIAL CABLE LOSS WHILE MEASURING EMP SIGNALS

被引:5
|
作者
Han, S. -M. [1 ]
Huh, C. S. [1 ]
Choi, J. S. [2 ]
机构
[1] Inha Univ, Dept Elect Engn, Inchon 402751, South Korea
[2] Agcy Def Dev, Taejon 305600, South Korea
关键词
POWER ELECTROMAGNETIC-WAVES; SUSCEPTIBILITY; MAGNETRON; DEVICES;
D O I
10.1163/156939309789932395
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accurate measurement of fast rise time EMP is critical. The loss and dispersion characteristics of signal measurement cables cause distortion in these measurements. To compensate for a distorted pulse, an appropriate compensation method is essential. Ordinary methods are not accurate, and the FFT calculation method requires a great deal of computer resources. An analytic derivate equation using Cauchy's theorem shows good results which have been proved by comparing the equation's results with real world pulse measurements.
引用
收藏
页码:1991 / 2000
页数:10
相关论文
共 50 条