Dual thermostating in flow analysis

被引:0
|
作者
Dias, Tuanne R. [1 ]
Sasaki, Milton K. [1 ]
Zagatto, Elias A. G. [1 ]
机构
[1] Univ Sao Paulo, Ctr Nucl Energy Agr, Av Centenario 303,POB 96, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Heat transfer unit; Dual temperature setting; Thermostating; Flow analysis; Temperature-dependent analytical methods; INJECTION ANALYSIS; SYSTEM; IODIDE;
D O I
10.1016/j.talanta.2017.03.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An advanced strategy involving concentric tubes is proposed for fast and controlled heating (or cooling) of the reaction medium in flow analysis. Different temperatures are set by sequentially circulating two thermostated water streams through the outer larged bore (2.0 mm i.d.) silicone tube, which acted as a water-jacket of the inner (0.8 mm i.d.) PTFE tube, and directing the sample zone to flow through it. Each end of the outer tube is connected to a three-way valve that selects the stream to flow inside it. For 25-85 cm tube lengths and a 12.0 mL min(-1) flow rate, the time interval required for temperature attainment, and the uniformity of temperature along the tube were evaluated. For the 85-cm tube, low differences in temperatures along the coil (1.1-8.7 degrees C) and between programmed and attained values (2.3-13.4 degrees C) were noted within a wide range of pre-set temperatures (15-75 degrees C). The feasibility of the innovation in flow analysis was demonstrated in a model system relying on the iodide-nitrite reaction. The strategy allows fast (15-120 s) thermostating of the reaction medium in a versatile and simple way, and is especially attractive when two controlled temperatures are set during the analytical course. Potentialities and limitations of the innovation are discussed.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 50 条
  • [21] CIRCUIT FOR PRECISION THERMOSTATING BASED ON AN INTEGRATED MICROCIRCUIT.
    Venkin, G.V.
    Kulyuk, L.L.
    Maleev, D.I.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1975, 18 (4 pt 2): : 1286 - 1287
  • [22] DUAL PARAMETER FLOW CYTOMETRIC AND HISTOPATHOLOGICAL ANALYSIS OF GASTRIC ADENOCARCINOMAS
    QUIRKE, P
    DYSON, J
    DIXON, M
    JOSLIN, CA
    BIRD, CC
    JOURNAL OF PATHOLOGY, 1984, 142 (02): : A25 - A25
  • [23] DUAL PARAMETER FLOW CYTOMETRIC AND HISTOPATHOLOGICAL ANALYSIS OF COLORECTAL CARCINOMAS
    QUIRKE, P
    DYSON, J
    DIXON, M
    JOSLIN, CA
    BIRD, CC
    JOURNAL OF PATHOLOGY, 1983, 141 (04): : 528 - 528
  • [24] Dual evolution mixed variational analysis of multiphase flow in the subsurface
    Gonzalo Alduncin
    GEM - International Journal on Geomathematics, 2021, 12
  • [25] A dual-beam thermal lens spectrometer for flow analysis
    Proskurnin, MA
    Abroskin, AG
    Yu, D
    Radushkevich, DY
    JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (01) : 91 - 97
  • [26] DUAL-PARAMETER FLOW MICROFLUOROMETER FOR RAPID CELL ANALYSIS
    MULLANEY, PF
    WEST, WT
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (10): : 1006 - 1008
  • [27] Dual evolution mixed variational analysis of multiphase flow in the subsurface
    Alduncin, Gonzalo
    GEM-INTERNATIONAL JOURNAL ON GEOMATHEMATICS, 2021, 12 (01)
  • [28] Analysis of dual solution for MHD flow of Williamson fluid with slippage
    Lund, Liaquat Ali
    Omar, Zurni
    Ilyas Khan
    HELIYON, 2019, 5 (03)
  • [29] Numerical analysis of supercritical flow instability in parallel dual channel
    Xiong, T., 1600, Yuan Zi Neng Chuban She (33):
  • [30] Characteristic analysis of dual direction pitot type flow meter
    Funaki, T
    Hou, J
    Nukui, K
    Kawashima, K
    Fujita, T
    Kagawa, T
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 1736 - 1739