SINGLE SHEAR BOLTED CONNECTIONS OF LIGHT GAUGE STEEL AT ELEVATED TEMPERATURES

被引:0
|
作者
Yan, S. [1 ]
Young, B. [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
MOMENT-CONNECTIONS; SHEET STEELS; MEMBERS;
D O I
10.3850/978-981-08-9247-0_rp019-icsas11
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The design formulas in the current specifications on bolted connections of light gauge steel for cold-formed steel structures are proposed based on ambient temperature tests. Investigations on this kind of connections at high temperatures are limited. In this study, a total of 73 single shear bolted connection specimens of G550 0.42mm and G450 1.90mm light gauge steel were tested in 7 different temperature levels range from 22 degrees C to 900 degrees C determined by the material coupon test results. Three failure modes were observed in the single shear bolted connection tests, namely the net section tension, bearing and tear out. The nominal strengths of bolted connections were calculated from the American, Australian/New Zealand and European specifications for cold-formed steel structures by using the reduced material properties at elevated temperatures, which were compared with the test results. The comparison shows that the strengths of the single shear bolted connections predicted by the specifications are generally conservative at elevated temperatures.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [21] Ultimate strength of single shear two-bolted connections with austenitic stainless steel
    Kim, TaeSoo
    Lim, JinSeong
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2013, 13 (01) : 117 - 128
  • [22] Net section tension capacity of high strength steel single shear bolted connections
    Lin, Xue-Mei
    Yam, Michael C. H.
    Song, Yuchen
    Chung, Kwok-Fai
    Ho, Ho-Cheung
    Han, Yawei
    THIN-WALLED STRUCTURES, 2024, 195
  • [23] Ultimate strength of single shear two-bolted connections with austenitic stainless steel
    TaeSoo Kim
    JinSeong Lim
    International Journal of Steel Structures, 2013, 13 : 117 - 128
  • [24] Effects of elevated temperatures on bolted moment-connections between cold-formed steel members
    Lim, James B. P.
    Young, Ben
    ENGINEERING STRUCTURES, 2007, 29 (10) : 2419 - 2427
  • [25] A PARAMETRIC STUDY ON BEARING STRENGTHS OF COLD-FORMED STAINLESS STEEL BOLTED CONNECTIONS AT ELEVATED TEMPERATURES
    Cai, Yancheng
    Young, Ben
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [26] Shear Behavior of Lapped Connections Bolted by thread-fixed one-side bolts at elevated temperatures
    Wang, Peijun
    You, Yang
    Xu, Qingfeng
    Wang, Qishuai
    Liu, Fangzhou
    FIRE SAFETY JOURNAL, 2021, 125
  • [27] Experimental and numerical studies on the behavior of high strength steel shear connections at elevated temperatures
    Wang, Weiyong
    Fang, Haojie
    Zhang, Linbo
    FIRE SAFETY JOURNAL, 2023, 139
  • [28] Block shear failure of austenitic stainless steel bolted connections
    Song, Yuchen
    Lin, Xue-Mei
    Yam, Michael C. H.
    Ke, Ke
    THIN-WALLED STRUCTURES, 2023, 193
  • [29] Mechanical properties of bolted connections for aluminum alloy structures at elevated temperatures
    Liu, Hongbo
    Liu, Xiaona
    Chen, Zhihua
    Ouyang, Yuanwen
    Yin, Jian
    THIN-WALLED STRUCTURES, 2020, 157
  • [30] Investigating the Effects of Adhesive on the Shear Capacity of Bolted Steel Connections
    Yasin, Bilal
    Almasaeid, Hatem
    Allouzi, Rabab
    Salman, Donia
    Abdalla, Khairedin
    Alkasassbeh, Abdelmajeed
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2024, 18 (02) : 224 - 238