Application of Monte Carlo to proton beam radiation therapy

被引:0
|
作者
Siebers, JV [1 ]
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Richmond, VA 23284 USA
关键词
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
As with photon and electron radiotherapy, the future of dose calculation for hadron beams will be based upon Monte Carlo algorithms. Benchmark calculations of the LAHET Monte Carlo code with respect to measured in-phantom dose distributions show that the proton physics modules in LAHET accurately reproduce measured results. Since MCNP-X incorporates the proton and high energy neutron physics modules from LAHET, similar agreement with MCNP-X is expected. In addition to beam-line simulations, MCNP-X has the ability to input the lattice geometry required for simulating patient treatments based on CT data sets. The ability of MCNP-X to perform patient dose calculation simulations for proton radiotherapy was demonstrated by simulating a two-beam prostate treatment plan. While MCNP-X is fully capable to perform patient-planning calculations, currently, it is too time consuming to be used for routine patient planning.
引用
收藏
页码:1051 / 1056
页数:6
相关论文
共 50 条
  • [21] Monte Carlo based treatment planning for modulated electron beam radiation therapy
    Lee, MC
    Deng, J
    Li, JS
    Jiang, SB
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08): : 2177 - 2199
  • [22] A reinforcement learning application of a guided Monte Carlo Tree Search algorithm for beam orientation selection in radiation therapy
    Sadeghnejad-Barkousaraie, Azar
    Bohara, Gyanendra
    Jiang, Steve
    Nguyen, Dan
    MACHINE LEARNING-SCIENCE AND TECHNOLOGY, 2021, 2 (03):
  • [23] A Reinforcement Learning Application of Guided Monte Carlo Tree Search Algorithm for Beam Orientation Selection in Radiation Therapy
    Barkousaraie, A. Sadeghnejad
    Ogunmolu, O.
    Jiang, S.
    Nguyen, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E236 - E236
  • [24] Application of Monte Carlo technology to fast dose calculation of radiation therapy
    Guan, Yonghong
    Huang, Jiaofeng
    Liu, Jin
    Liu, Jun
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2013, 25 (01): : 193 - 195
  • [25] Application of four-dimensional Monte Carlo in dynamic radiation therapy
    Paganetti, H
    Jiang, H
    Rietzel, E
    Trofimov, A
    Gierga, D
    Adams, JA
    Chen, GTY
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S88 - S88
  • [26] Clinical use of Monte Carlo in proton therapy: Pencil-beam algorithm vs Monte Carlo for proton therapy of skull-base and para-spinal tumors
    Paganetti, H.
    Parodi, K.
    Adams, J.
    Kooy, H.
    MEDICAL PHYSICS, 2006, 33 (06) : 2286 - 2286
  • [27] A Monte Carlo study of different LET definitions and calculation parameters for proton beam therapy
    Smith, Edward A. K.
    Winterhalter, Carla
    Underwood, Tracy S. A.
    Aitkenhead, Adam H.
    Richardson, Jenny C.
    Merchant, Michael J.
    Kirkby, Norman F.
    Kirby, Karen J.
    Mackay, Ranald, I
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (01)
  • [28] An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle
    Sawakuchi, Gabriel O.
    Mirkovic, Dragan
    Perles, Luis A.
    Sahoo, Narayan
    Zhu, X. Ron
    Ciangaru, George
    Suzuki, Kazumichi
    Gillin, Michael T.
    Mohan, Radhe
    Titt, Uwe
    MEDICAL PHYSICS, 2010, 37 (09) : 4960 - 4970
  • [29] On the accuracy of Monte Carlo based beam dynamics models for the degrader in proton therapy facilities
    Rizzoglio, V
    Adelmann, A.
    Baumgarten, C.
    Meer, D.
    Snuverink, J.
    Talanov, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 898 : 1 - 10
  • [30] Performance of a Hybrid Monte Carlo-Pencil Beam Dose Algorithm for Proton Therapy
    Montero, A. Barragan
    Souris, K.
    Sanchez-Parcerisa, D.
    Lee, J.
    Sterpin, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 2994 - 2994