Implementation of a design of experiments to study the influence of the background electrolyte on separation and detection in non-aqueous capillary electrophoresis-mass spectrometry

被引:21
|
作者
Posch, Tjorben Nils [1 ]
Mueller, Alexander [2 ]
Schulz, Wolfgang [2 ]
Puetz, Michael [3 ]
Huhn, Carolin [1 ]
机构
[1] Forschungszentrum Julich, Cent Div Analyt Chem, D-52425 Julich, Germany
[2] Landeswasserversorgung, Lab Operat Control & Res, Langenau, Germany
[3] KT 34 Toxicol, Bundeskriminalamt Fed Criminal Police Off, Forens Sci Inst, Wiesbaden, Germany
关键词
Design of experiments; Heteroconjugation; Indole alkaloids; Ion-pairing; Non-aqueous capillary electrophoresis; ZONE-ELECTROPHORESIS; BASIC DRUGS; ALKALOIDS; OPTIMIZATION; SELECTIVITY; ACIDS; PARAMETERS; MOBILITY; MEDIA; ACETONITRILE;
D O I
10.1002/elps.201100381
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Non-aqueous capillary electrophoresis (NACE) background electrolytes are most often composed of a mixture of methanol and acetonitrile (ACN) with soluble ammonium salts added as electrolyte. In this study on NACE-MS, we used a mixture of glacial acetic acid and ACN giving rise to an acidic background electrolyte (BGE) with a very low dielectric constant. Impressive changes in selectivity and resolution were observed for structurally closely related indole alkaloids including diastereomers upon addition of ammonium formate as electrolyte and upon variation of the solvent ratio. In order to obtain best separation and MS detection conditions and to reveal the influence of the parameters of the BGE on separation and detection and vice versa of the MS parameters on separation, an optimization strategy was employed using a design of experiments in a central composite design with response surface methodology. It was proven that at high electroosmotic flow conditions capillary electrophoretic separations and thus optimization can be realized without interference from the coupling to an MS system. Several significantly interacting parameters were revealed, which are not accessible with classical univariate optimization approaches. With this optimization, alkaloid mixtures from a plant extract of Mitragyna speciosa, containing a large number of diastereomeric compounds were successfully separated.
引用
收藏
页码:583 / 598
页数:16
相关论文
共 50 条
  • [41] Non-aqueous capillary electrophoresis for the analysis of acidic compounds using negative electrospray ionization mass spectrometry
    Bonvin, Gregoire
    Schappler, Julie
    Rudaz, Serge
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1323 : 163 - 173
  • [42] Analysis of neutral surfactants by non-aqueous medium capillary electrophoresis hyphenated to mass spectrometry (ion trap)
    Morin, C. J.
    Geulin, L.
    Mofaddel, N.
    Desbene, A. M.
    Desbene, P. L.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1198 (1-2) : 226 - 231
  • [43] Non-aqueous capillary electrophoresis-time of flight mass spectrometry method to determine emerging mycotoxins
    del Mar Delgado-Povedano, Maria
    Lara, Francisco J.
    Gamiz-Gracia, Laura
    Garcia-Campana, Ana M.
    TALANTA, 2023, 253
  • [44] Interlaboratory study to evaluate the robustness of capillary electrophoresis-mass spectrometry for peptide mapping
    Wenz, Christian
    Barbas, Coral
    Lopez-Gonzalvez, Angeles
    Garcia, Antonia
    Benavente, Fernando
    Sanz-Nebot, Victoria
    Blanc, Tim
    Freckleton, Gordon
    Britz-McKibbin, Philip
    Shanmuganathan, Meera
    de l'Escaille, Francois
    Far, Johann
    Haselberg, Rob
    Huang, Sean
    Huhn, Carolin
    Pattky, Martin
    Michels, David
    Mou, Si
    Yang, Feng
    Neusuess, Christian
    Tromsdorf, Nora
    Baidoo, Edward E. K.
    Keasling, Jay D.
    Park, SungAe Suhr
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (18) : 3262 - 3270
  • [45] Capillary Electrophoresis-Mass Spectrometry-Based Detection of Drugs and Neurotransmitters in Drosophila Brain
    Phan, Nhu T. N.
    Hanrieder, Jorg
    Berglund, E. Carina
    Ewing, Andrew G.
    ANALYTICAL CHEMISTRY, 2013, 85 (17) : 8448 - 8454
  • [47] Simplifying capillary electrophoresis-mass spectrometry operation: Eliminating capillary derivatization by using self-coating background electrolytes
    Garza, Selynda
    Chang, Silvia
    Moini, Mehdi
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) : 14 - 21
  • [49] Determination of quercetin in tablets by non-aqueous capillary electrophoresis with conductivity detection
    Zheng, YP
    Mo, JY
    Xie, TY
    Huang, JL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (11) : 1379 - 1382
  • [50] Improvement of Separation in Non-Aqueous Capillary Electrophoresis using Surfactants and Calixarenes as Additives
    Hisham, Hashem
    Andre, Kaessler
    Thomas, Jira
    CURRENT ANALYTICAL CHEMISTRY, 2012, 8 (01) : 124 - 132