Thermodynamic properties of hydrofluoroolefin (R1234yf and R1234ze(E)) refrigerant mixtures: Density, vapour-liquid equilibrium, and heat capacity data and modelling

被引:58
|
作者
Al Ghafri, Saif Z. S. [1 ]
Rowland, Darren [1 ]
Akhfash, Masoumeh [1 ]
Arami-Niya, Arash [1 ]
Khamphasith, Martin [1 ]
Xiao, Xiong [1 ]
Tsuji, Tomoya [2 ]
Tanaka, Yukio [3 ]
Seiki, Yoshio [4 ]
May, Eric F. [1 ]
Hughes, Thomas J. [5 ]
机构
[1] Univ Western Australia, Dept Chem Engn, Fluid Sci & Resources Div, Crawley, WA 6009, Australia
[2] Univ Teknol Malaysia, Malaysia Japan Int Inst Technol, Kuala Lumpur 54100, Malaysia
[3] Mitsubishi Heavy Ind Co Ltd, Res & Innovat Ctr, Chem Res Dept, Hiroshima 7338553, Japan
[4] Mitsubishi Heavy Ind Asia Pacific Pte Ltd, Global Res & Innovat Ctr, Singapore 189720, Singapore
[5] Monash Univ, Dept Civil Engn, Oil & Gas Engn Resources Engn, Clayton, Vic 3800, Australia
关键词
Hydrofluoroolefins; Vapour-liquid equilibrium; Density; Heat capacity; DIFFERENTIAL SCANNING CALORIMETRY; EQUATION-OF-STATE; INTERNATIONAL STANDARD FORMULATION; BUBBLE POINT PRESSURE; METHANE PLUS ETHANE; BINARY-MIXTURES; TEMPERATURES; PHASE; PROPANE; SYSTEMS;
D O I
10.1016/j.ijrefrig.2018.10.027
中图分类号
O414.1 [热力学];
学科分类号
摘要
Liquid-phase and vapour-phase densities are reported for the binary refrigerant mixtures (R125 + R1234ze(E)), (R134a + R1234ze(E)), (R143a + R1234ze(E)), (R1234ze(E) + R1234yf), (R125 + R1234yf), (R143a + R1234yf) and (R125 + R152a). The measurements span temperatures from (252 to 294) K and pressures from (0.8 to 4.2) MPa. Vapour-liquid equilibria (VLE) and liquid isobaric heat capacities are also reported for some mixtures. These measurements and previously published data were used to tune binary interaction parameters in existing Helmholtz energy models. Significant improvements in the predicted densities were achieved, for example the root mean squared relative deviation decreased from 0.33% to 0.021% for (R143a + R1234yf). The most significant improvement in the description of VLE occurred for (R1234yf + R1234ze(E)) where the root mean squared deviation in the predicted vapour phase compositions decreased from 0.010 to 0.00084 (a factor of 12). (C) 2018 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:249 / 260
页数:12
相关论文
共 50 条
  • [31] R1234yf and R1234ze(E) as environmentally friendly replacements of R134a: Assessing flow boiling on an experimental basis
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 336 - 346
  • [32] Experimental and Numerical Studies on an Automobile Air Conditioning System With the Refrigerants R134a, R1234yf, and R1234ze(E)
    Gurudatt, H. M.
    Narasimham, G. S. V. L.
    Sadashive Gowda, B.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (01)
  • [33] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Li, Shizhen
    Liu, Yingxin
    Liu, Yanjun
    Zhang, Jingzhi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (40) : 57166 - 57182
  • [34] Performance comparison of ejectors in ejector-based refrigeration cycles with R1234yf, R1234ze(E) and R134a
    Shizhen Li
    Yingxin Liu
    Yanjun Liu
    Jingzhi Zhang
    Environmental Science and Pollution Research, 2021, 28 : 57166 - 57182
  • [35] A regressive model for dynamic impulsive instabilities during the condensation of R134a, R1234ze(E) and R1234yf refrigerants
    Kuczyński, Waldemar
    Charun, Henryk
    Piątkowski, Piotr
    Balasz, Blażej
    Chliszcz, Katarzyna
    Kuczyński, Waldemar (waldemar.kuczynski@tu.koszalin.pl), 1600, Elsevier Ltd (169):
  • [36] Performance evaluation of VCR system with pure and various blends of R134a, R1234yf, and R1234ze (E) refrigerants
    Kuwar, Yogendra Vasantrao
    HEAT TRANSFER, 2024, 53 (06) : 2879 - 2904
  • [37] A regressive model for dynamic impulsive instabilities during the condensation of R134a, R1234ze(E) and R1234yf refrigerants
    Kuczynski, Waldemar
    Charun, Henryk
    Piatkowski, Piotr
    Balasz, Blazej
    Chliszcz, Katarzyna
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 169
  • [38] Retrofitting an air-conditioning device to utilize R1234yf and R1234ze(E) refrigerants as alternatives to R22
    Vedat Oruç
    Atilla G. Devecioğlu
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40
  • [39] Measurement of vapor-liquid equilibrium for R32+R1234yf+R1234ze(E)
    Sun, Yukun
    Yang, Tao
    Wu, Jiangtao
    Huagong Xuebao/CIESC Journal, 2022, 73 (03): : 1063 - 1071
  • [40] Measurement and Correlation for the Viscosity of R1234yf/POE85 and R1234ze(E)/POE85 Solutions
    Sun, Yanjun
    Wang, Xingdan
    Wei, Qiming
    Wang, Xiaopo
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2022, 67 (12): : 3557 - 3563