Investigation of the performance of 7LiF:Mg,Cu,P under environmental conditions

被引:4
|
作者
Ranogajec-Komor, M
Klemic, G
Sengupta, S
Knezevic, Z
Raccah, F
Vekic, B
机构
[1] Rudjer Boskovic Inst, Zagreb 10000, Croatia
[2] US DOE, Environm Measurements Lab, New York, NY 10014 USA
[3] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a032838
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The high gamma sensitivity demonstrated by LiF:Mg,Cu,P produced in China and Poland makes it appropriate for environmental applications. Recently a new version of this material has been produced in the United States in both loose chip and encapsulated card form. This study investigates the performance of the US material under conditions designed to simulate environmental insults as described in ANSI Draft Standard N13.29. Twenty dosemeters are placed in an environmental chamber that cycles twice through three 15 day periods of temperature and humidity conditions: -20 degrees C; +50 degrees C with 20% relative humidity; and +50 degrees C with 90% relative humidity. Five randomly selected dosemeters are exposed to a Cs-137 source that will give doses between 0.5 to 10.0 mSv at the beginning, middle, and end of the 90 day test. Two 40 W fluorescent bulbs provide lighting in the chamber. Performance is measured by comparison with the proposed Draft N13.29 performance criteria that would require the absolute value of the bias and standard deviation to each be less than or equal to 0.35, while their sum must be less than or equal to 0.50.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 50 条
  • [31] The investigation of LiF:Mg,Cu,P thermoluminescent detectors; The dose response to gamma radiation
    Ramlo, MJ
    Bicron, NE
    Karpov, NA
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D421 - D421
  • [32] Optical absorption in LiF, LiF:Mg, LiF:Mg,Cu,P irradiated with high gamma and beta doses
    Remy, K.
    Sholom, S.
    Obryk, B.
    McKeever, S. W. S.
    RADIATION MEASUREMENTS, 2017, 106 : 113 - 117
  • [33] On the linearity of the high-temperature emission from 7LiF:Mg,Ti (TLD-700)
    Berger, T.
    Hajek, M.
    RADIATION MEASUREMENTS, 2008, 43 (9-10) : 1467 - 1473
  • [34] Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P
    Baker, S. T.
    Gilvin, P. J.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 258 - 260
  • [35] Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P
    Luo, LZ
    Velbeck, KJ
    Rotunda, JE
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 211 - 216
  • [36] Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P
    Luo, LZ
    Velbeck, KJ
    Rotunda, JE
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A211 - A216
  • [37] Role of impurities in the thermoluminescence of LiF:Mg,Cu,P
    Chen, TC
    Stoebe, TG
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 243 - 246
  • [38] Low temperature studies in LiF:Mg,Cu,P
    Mathur, VK
    Bandyopadhyay, PK
    Barkyoumb, JH
    Cai, GG
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 103 - 106
  • [39] DOSE REASSESSMENT OF LIF-MG,CU,P
    DRISCOLL, CMH
    RADIATION PROTECTION DOSIMETRY, 1987, 19 (01) : 59 - 61
  • [40] Low temperature radioluminescence of LiF:Mg,Cu,P
    Kurt, K.
    Mathur, V. K.
    McKeever, S. W. S.
    Townsend, P. D.
    Valberg, L.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 134 - 138