Investigation of the performance of 7LiF:Mg,Cu,P under environmental conditions

被引:4
|
作者
Ranogajec-Komor, M
Klemic, G
Sengupta, S
Knezevic, Z
Raccah, F
Vekic, B
机构
[1] Rudjer Boskovic Inst, Zagreb 10000, Croatia
[2] US DOE, Environm Measurements Lab, New York, NY 10014 USA
[3] Brookhaven Natl Lab, Upton, NY 11973 USA
关键词
D O I
10.1093/oxfordjournals.rpd.a032838
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The high gamma sensitivity demonstrated by LiF:Mg,Cu,P produced in China and Poland makes it appropriate for environmental applications. Recently a new version of this material has been produced in the United States in both loose chip and encapsulated card form. This study investigates the performance of the US material under conditions designed to simulate environmental insults as described in ANSI Draft Standard N13.29. Twenty dosemeters are placed in an environmental chamber that cycles twice through three 15 day periods of temperature and humidity conditions: -20 degrees C; +50 degrees C with 20% relative humidity; and +50 degrees C with 90% relative humidity. Five randomly selected dosemeters are exposed to a Cs-137 source that will give doses between 0.5 to 10.0 mSv at the beginning, middle, and end of the 90 day test. Two 40 W fluorescent bulbs provide lighting in the chamber. Performance is measured by comparison with the proposed Draft N13.29 performance criteria that would require the absolute value of the bias and standard deviation to each be less than or equal to 0.35, while their sum must be less than or equal to 0.50.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 50 条
  • [1] Estimation of ambient dose equivalent from environmental radiation using a 7LiF:Mg,Cu,P thermoluminescence dosemeter
    Cherestes, C.
    Cherestes, M.
    Constantinescu, L. M.
    Paraschiva, M. V.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (11): : 1159 - 1161
  • [2] Monte Carlo modelling of a TLD device containing 7LiF:Mg,Cu,P detectors
    Eakins, J. S.
    Bartlett, D. T.
    Hager, L. G.
    Tanner, R. J.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 631 - 635
  • [3] Response of 6LiF:Mg,Cu,Si and 7LiF:Mg,Cu,Si TLD Pairs to the Neutrons and Photon Mixtures
    Lee, J. I.
    Pradhan, A. S.
    Kim, J. L.
    Kim, B. H.
    Yim, K. S.
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 233 - 236
  • [5] Role of dopants in LiF:Mg,Cu, LiF:Mg,P and LiF:Mg,Cu,P detectors
    Mohammadi, Kh
    Zarandi, A. Moussavi
    Afarideh, H.
    Shahmaleki, S.
    JOURNAL OF SOLID STATE CHEMISTRY, 2013, 202 : 282 - 290
  • [6] Recent improvements in LiF:Mg,Ti and LiF:Mg,Cu,P based environmental dosimetry
    Delgado, A
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 129 - 134
  • [7] Characterization of 7LiF:Mg,Ti TLD micro-cubes
    Bassinet, C.
    Robbes, I.
    Barbier, L.
    Baumann, M.
    Kernisant, B.
    Trompier, F.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 646 - 648
  • [8] Optical and thermoluminescence properties of LiF:Cu, LiF:Mg,Cu and LiF:Mg,Cu,P single crystals
    Chernov, V
    Mironenko, S
    Rogalev, B
    Bos, AJJ
    de Haas, JTM
    Delgado, A
    RADIATION MEASUREMENTS, 1998, 29 (3-4) : 365 - 372
  • [9] Dosimetry performance of LiF(Mg, Cu, P) thermoluminescence detector
    Wang, X., 1888, Atomic Energy Press (47):
  • [10] A comparative study on the thermal stability of LiF:Mg,Ti and LiF:Mg,Cu,P detectors for environmental monitoring
    Alves, JG
    Muñiz, JL
    Ros, JMG
    Delgado, A
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 253 - 257