Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator

被引:22
|
作者
Lee, Hyun-Joo [1 ]
Oh, Chang-Wug [1 ]
Oh, Jong-Keon [2 ]
Apivatthakakul, Theerachai [3 ]
Kim, Joon-Woo [1 ]
Yoon, Jong-Pil [1 ]
Lee, Dong-Joo [1 ]
Jung, Jae-Wook [1 ]
机构
[1] Kyungpook Natl Univ Hosp, Dept Orthopaed Surg, Taegu 700721, South Korea
[2] Korea Univ, Guro Hosp, Dept Orthopaed Surg, Seoul, South Korea
[3] Chiang Mai Univ, Fac Med, Dept Orthoped, Chiang Mai 50000, Thailand
关键词
Humerus; Shaft fracture; MIPO; External fixator; RADIAL NERVE PALSY; AXILLARY NERVE; DISTAL; 3RD; SHOULDER; MIPO; MANAGEMENT; ANTEGRADE; MIDDLE;
D O I
10.1007/s00402-013-1708-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. There was no case of mal-union > 10A degrees, and mean angulation was 1.3A degrees (range 0A degrees-9A degrees) in the coronal plane and 1.2A degrees (range 0A degrees-8A degrees) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates. IV.
引用
收藏
页码:649 / 657
页数:9
相关论文
共 50 条
  • [31] Minimally invasive plating osteosynthesis technique applied to humeral shaft fractures: the lateral approach
    Spagnolo, Rosario
    Pace, Fabrizio
    Bonalumi, Matteo
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (03): : 205 - 210
  • [32] Minimally invasive plating osteosynthesis technique applied to humeral shaft fractures: the lateral approach
    Rosario Spagnolo
    Fabrizio Pace
    Matteo Bonalumi
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 205 - 210
  • [33] Minimally invasive plate osteosynthesis for proximal humeral fractures
    Sinha, Nirmal
    Rao, Belpu Seetharama
    Trivedy, Prabhanjanesh Datta
    Rao, Ashutosh Sadashiva
    JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (01) : 139 - 139
  • [34] Comparison of two external fixator systems for fracture reduction during minimally invasive plate osteosynthesis in simulated antebrachial fractures
    Gilbert, Erika D.
    Lewis, Daniel D.
    Townsend, Sarah
    Kim, Stanley E.
    VETERINARY SURGERY, 2017, 46 (07) : 971 - 980
  • [35] Minimal invasive plate osteosynthesis for the dislocated humeral head fracture associated with ipsilateral humeral shaft fracture: A case report
    Nhat Pham Van
    Hieu Nguyen
    Tuan Nguyen Anh
    Xuan Tran Chanh
    ORTHOPEDIC REVIEWS, 2023, 15
  • [36] Minimally invasive plate osteosynthesis for proximal humeral fractures
    Koljonen, Paul Aarne
    Fang, Christian
    Lau, Tak Wing
    Leung, Frankie
    Cheung, Nigel W. K.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 160 - 163
  • [37] Posterior Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: An Anatomic Study of "Danger Zones"
    Rebehn, Kelsey A.
    Cannada, Lisa K.
    Watson, J. Tracy
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2020, 21 (02): : 50 - 53
  • [38] MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS (MIPO) IN HUMERAL SHAFT FRACTURES - BIOMECHANICS - DESIGN - CLINICAL RESULTS
    Sanjeevaiah
    Reddy, Praneeth
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (54): : 9449 - 9456
  • [39] Minimally invasive plate osteosynthesis for clavicle shaft fractures
    Burkhard, M. D.
    Michelitsch, C.
    Stillhard, P. F.
    Mueller, T.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2022, 109 (SUPPL 3)
  • [40] Minimally invasive plate osteosynthesis with locking plate for metastatic humeral fractures
    Matsumura, Tomohiro
    Saito, Tomohiro
    Akiyama, Toru
    Takeshita, Katsushi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (06) : 1309 - 1314