Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator

被引:22
|
作者
Lee, Hyun-Joo [1 ]
Oh, Chang-Wug [1 ]
Oh, Jong-Keon [2 ]
Apivatthakakul, Theerachai [3 ]
Kim, Joon-Woo [1 ]
Yoon, Jong-Pil [1 ]
Lee, Dong-Joo [1 ]
Jung, Jae-Wook [1 ]
机构
[1] Kyungpook Natl Univ Hosp, Dept Orthopaed Surg, Taegu 700721, South Korea
[2] Korea Univ, Guro Hosp, Dept Orthopaed Surg, Seoul, South Korea
[3] Chiang Mai Univ, Fac Med, Dept Orthoped, Chiang Mai 50000, Thailand
关键词
Humerus; Shaft fracture; MIPO; External fixator; RADIAL NERVE PALSY; AXILLARY NERVE; DISTAL; 3RD; SHOULDER; MIPO; MANAGEMENT; ANTEGRADE; MIDDLE;
D O I
10.1007/s00402-013-1708-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. There was no case of mal-union > 10A degrees, and mean angulation was 1.3A degrees (range 0A degrees-9A degrees) in the coronal plane and 1.2A degrees (range 0A degrees-8A degrees) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates. IV.
引用
收藏
页码:649 / 657
页数:9
相关论文
共 50 条
  • [1] Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
    Hyun-Joo Lee
    Chang-Wug Oh
    Jong-Keon Oh
    Theerachai Apivatthakakul
    Joon-Woo Kim
    Jong-Pil Yoon
    Dong-Joo Lee
    Jae-Wook Jung
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 649 - 657
  • [2] Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?
    Concha, Juan M.
    Sandoval, Alejandro
    Streubel, Philipp N.
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1297 - 1305
  • [3] Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?
    Juan M. Concha
    Alejandro Sandoval
    Philipp N. Streubel
    International Orthopaedics, 2010, 34 : 1297 - 1305
  • [4] Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: A Technique to Aid Fracture Reduction and Minimize Complications
    Shin, Sang-Jin
    Sohn, Hoon-Sang
    Do, Nam-Hoon
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (10) : 585 - 589
  • [5] Comparison of minimally invasive plate osteosynthesis and conventional plate osteosynthesis for humeral shaft fracture: A meta-analysis
    Yu, Bin-feng
    Liu, Liang-le
    Yang, Guo-jing
    Zhang, Lei
    Lin, Xi-peng
    MEDICINE, 2016, 95 (39)
  • [6] Minimally Invasive Anterior Plate Osteosynthesis in Humeral Shaft Fractures
    Nikolaus Schwarz
    Manfred Windisch
    Birgit Mayr
    European Journal of Trauma and Emergency Surgery, 2009, 35 : 271 - 276
  • [7] Minimally Invasive Anterior Plate Osteosynthesis in Humeral Shaft Fractures
    Schwarz, Nikolaus
    Windisch, Manfred
    Mayr, Birgit
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2009, 35 (03) : 271 - 276
  • [8] Minimally Invasive Plate Osteosynthesis (MIPO) technique for complex tibial shaft fracture
    Choi, Sungwook
    Lee, Tong Joo
    Kim, Shinil
    Cho, Changhee
    Shim, Seungjae
    Kang, Hyunseong
    ACTA ORTHOPAEDICA BELGICA, 2019, 85 (02): : 224 - 233
  • [9] Minimally Invasive Plate Osteosynthesis of Humeral Shaft Fractures: A Technique to Aid Fracture Reduction and Minimize Complications Invited Commentary
    McKee, Michael D.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (10) : 589 - 590
  • [10] Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture
    T. W. Lau
    F. Leung
    C. F. Chan
    S. P. Chow
    International Orthopaedics, 2007, 31 : 657 - 664