Incomplete capsular bag distension syndrome after neodymium:YAG capsulotomy

被引:2
|
作者
Agrawal, S [1 ]
Agrawal, J [1 ]
Agrawal, TP [1 ]
机构
[1] TP Agrawal Inst Ophthalmol, Meerut 250001, Uttar Pradesh, India
来源
关键词
D O I
10.1016/j.jcrs.2005.07.017
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We report a 60-year-old man with incomplete capsular bag distension syndrome 2 years after neodymium:YAG (Nd:YAG) laser capsulotomy for capsule opacification, which developed from extracapsular cataract extraction with intraocular lens (IOL) implantation performed 4 years before presentation to our clinic. The patient reported floaters of 15 days duration. Slitlamp examination showed shallowing of the inferior and medial anterior chamber. Dilated pupil examination showed a peripheral capsular bag inferiorly and medially behind the IOL. The bag was distended and filled with turbid fluid. The central and superior capsule was absent as a result of the previous Nd:YAG treatment. The IOL lie over the anterior capsule, and peripheral capsule leaves' edges were adhered. An Nd:YAG laser puncture of the incomplete capsular bag resolved the condition.
引用
收藏
页码:351 / 352
页数:2
相关论文
共 50 条
  • [31] Delayed Rapid-Onset Capsular Bag Distension Syndrome
    Goerlitz-Jessen, Mark
    Dagli, Manesh
    OPHTHALMOLOGY GLAUCOMA, 2019, 2 (06): : 412 - 412
  • [32] Differential optical density of fluid in capsular bag distension syndrome
    Oli, Avadhesh
    Malik, Robin
    Waikar, Shrikant
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (12): : E20 - E21
  • [33] Postoperative Capsular Bag Distension Syndrome - Risk Factors and Treatment
    Kanclerz, Piotr
    Wang, Xiaogang
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (06) : 409 - 419
  • [34] Intraocular pressure rise and recurrence of capsular block syndrome after neodymium:YAG laser anterior capsulotomy (vol 33, pg 1344, 2007)
    Colakoglu, A.
    Kucukakyuz, N.
    Topcuoglu, I. E.
    Akar, S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10): : 1679 - 1679
  • [35] Elschnig pearl formation along the posterior capsulotomy margin after neodymium:YAG capsulotomy
    Kato, K
    Kurosaka, D
    Bissen-Miyajima, H
    Negishi, K
    Hara, E
    Nagamoto, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (10): : 1556 - 1560
  • [36] Reopening of 2 macular holes after neodymium:YAG capsulotomy
    García-Arumí, J
    Palau, MM
    Espax, AB
    Martínez-Castillo, V
    Garrido, HB
    Corcóstegui, B
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02): : 363 - 366
  • [37] Retinal breaks before and after neodymium:YAG posterior capsulotomy
    Ranta, P
    Tommila, P
    Immonen, I
    Summanen, P
    Kivelä, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08): : 1190 - 1197
  • [38] UVEOSCLERITIS AFTER EXCESSIVE NEODYMIUM - YAG LASER POSTERIOR CAPSULOTOMY
    HERBORT, CP
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (01): : 80 - 81
  • [39] Changes in intraocular lens position after neodymium:YAG capsulotomy
    Findl, O
    Drexler, W
    Menapace, R
    Georgopoulos, M
    Rainer, G
    Hitzenberger, CK
    Fercher, AF
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (05): : 659 - 662
  • [40] Delayed intraocular lens dislocation after neodymium:YAG capsulotomy
    Framme, C
    Hoerauf, H
    Roider, J
    Laqua, H
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (11): : 1541 - 1543