Transcatheter and endovascular stent graft management of coarctation-related pseudoaneurysms

被引:14
|
作者
Khavandi, A. [1 ]
Bentham, J. [3 ]
Marlais, M. [1 ]
Martin, R. P. [1 ]
Morgan, G. J. [1 ]
Parry, A. J. [1 ]
Brooks, M. J. [1 ]
Manghat, N. E. [1 ,2 ]
Hamilton, M. C. K. [1 ,2 ]
Baumbach, A. [1 ]
McPherson, S. [3 ]
Thomson, J. D. [3 ]
Turner, M. S. [1 ]
机构
[1] Bristol Royal Infirm & Gen Hosp, Univ Hosp Bristol NHS Fdn Trust, Bristol Heart Inst, Dept Cardiol, Bristol BS2 8HW, Avon, England
[2] Bristol Royal Infirm & Gen Hosp, Cardiovasc Biomed Res Unit, Bristol Heart Inst, NIHR, Bristol BS2 8HW, Avon, England
[3] Leeds Gen Infirm, Leeds Teaching Hosp NHS Trust, Dept Cardiol, Leeds, W Yorkshire, England
关键词
Congenital Heart Disease; LEFT SUBCLAVIAN ARTERY; TERM-FOLLOW-UP; THORACIC AORTIC-ANEURYSMS; SURGICAL-CORRECTION; REPAIR; SURGERY;
D O I
10.1136/heartjnl-2012-303488
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Surgical correction of congenital aortic coarctation can lead to a number of important problems including late pseudoaneurysm formation. Redo surgery has a significant risk. Endovascular stent graft repair is increasingly used but there are limited data regarding this indication. We describe the experience of two UK congenital referral centres. Design Retrospective analysis of patients treated with endovascular aortic stent grafting for late pseudoaneurysms. Setting Two UK congenital heart centres, Bristol Heart Institute and Leeds General Infirmary. Patients 17 patients were treated 2006-2012. This represents all patients treated with this technique. Main outcome measures Procedural and postprocedure success and complications. Results The average time from index repair to endovascular repair of pseudoaneurysm was 24.6years. The majority (70.6%) had patch aortoplasty as the original surgical procedure and 41.2% were not under follow-up or discharged. Stent grafting procedural success rate was 100%. Median hospital stay postprocedure was 3days. There was no procedural mortality or immediate complication. There were four minor early and three minor late complications. Imaging follow-up was available for an average of 31.6months (range 6-65months). All patients have demonstrated positive remodelling of the pseudoaneurysm with no incidence of continued expansion or stent graft failure up to 5years following implant. Conclusions Endovascular stent graft treatment of pseudoaneurysms show promising results in a population who have a high risk of surgical re-intervention. Complication rates appear to be low and recovery is quick. Longer-term data remain essential to scrutinise stent graft performance in this situation.
引用
收藏
页码:1275 / 1281
页数:7
相关论文
共 50 条
  • [21] Endovascular Treatment for Pseudoaneurysms after Surgical Correction of Aortic Coarctation
    Rabellino, M.
    Zander, T.
    Gonzalez, G.
    Baldi, S.
    Cheves, H.
    Estigarribia, A.
    Llorens, R.
    Carreira, J. M.
    Maynar, M.
    CARDIOLOGY RESEARCH AND PRACTICE, 2011, 2011
  • [22] Endovascular management of traumatic pseudoaneurysms
    Lauren Shreve
    Maha Jarmakani
    Hanna Javan
    Ivan Babin
    Kari Nelson
    James Katrivesis
    Michael Lekawa
    Eric Kuncir
    Dayantha Fernando
    Nadine Abi-Jaoudeh
    CVIR Endovascular, 3
  • [23] Endovascular management of traumatic pseudoaneurysms
    Shreve, Lauren
    Jarmakani, Maha
    Javan, Hanna
    Babin, Ivan
    Nelson, Kari
    Katrivesis, James
    Lekawa, Michael
    Kuncir, Eric
    Fernando, Dayantha
    Abi-Jaoudeh, Nadine
    CVIR ENDOVASCULAR, 2020, 3 (01)
  • [24] Management of an infected aortic graft with endovascular stent grafting
    Jamel, Sara
    Attia, Rizwan
    Young, Christopher
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2013, 19 (01) : 66 - 69
  • [25] Endovascular repair of recurrent aortic coarctation with a custom made hourglass shaped stent graft
    Mallios, Alexandros
    Haulon, Stephan
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (03) : 1067 - 1068
  • [26] Endovascular management of a significantly kinked aortomonoiliac stent graft
    Bartoli, Michel A.
    Millon, Antoine
    Magnan, Pierre Edouard
    Branchereau, Alain
    VASCULAR, 2008, 16 (02) : 112 - 115
  • [27] Endovascular Management of Visceral Artery Pseudoaneurysms: Transcatheter Coil Embolization Using the Isolation Technique
    Osamu Ikeda
    Yutaka Nakasone
    Yoshitaka Tamura
    Yasuyuki Yamashita
    CardioVascular and Interventional Radiology, 2010, 33 : 1128 - 1134
  • [28] Endovascular Management of Visceral Artery Pseudoaneurysms: Transcatheter Coil Embolization Using the Isolation Technique
    Ikeda, Osamu
    Nakasone, Yutaka
    Tamura, Yoshitaka
    Yamashita, Yasuyuki
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (06) : 1128 - 1134
  • [29] Stent Graft in the Treatment of Pseudoaneurysms of the Hepatic Arteries
    Lu, Peng-Hua
    Zhang, Xi-Cheng
    Wang, Li-Fu
    Chen, Zhao-Lei
    Shi, Hai-Bin
    VASCULAR AND ENDOVASCULAR SURGERY, 2013, 47 (07) : 551 - 554
  • [30] Endovascular Stent-graft Management of Aortic Intramural Hematomas
    Monnin-Bares, Valerie
    Thony, Frederic
    Rodiere, Mathieu
    Bach, Vincent
    Hacini, Rachid
    Blin, Dominique
    Ferretti, Gilbert
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (06) : 713 - 721