Clinical outcomes and costs of conventional and digital complete dentures in a university clinic: A retrospective study

被引:17
|
作者
Arakawa, Itsuka [1 ]
Husain, Nadin Al-Haj [2 ]
Srinivasan, Murali [3 ,6 ]
Maniewicz, Sabrina [4 ]
Abou-Ayash, Samir [5 ]
Schimmel, Martin [6 ,7 ,8 ]
机构
[1] Nippon Dent Univ, Comprehens Dent Care Unit, Niigata Hosp, Niigata, Japan
[2] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[3] Univ Zurich, Ctr Dent Med, Clin Gen Special Care & Geriatr Dent, Zurich, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[5] Univ Bern, Sch Dent, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dept DIRecD, Bern, Switzerland
[6] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Extra muros, Geneva, Switzerland
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[8] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 03期
关键词
CAD-CAM;
D O I
10.1016/j.prosdent.2020.12.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Scientific data analyzing the clinical outcomes and costs of complete dentures fabricated by using conventional and computer-aided design and computer-aided manufacturing (CAD-CAM) processes are lacking.Purpose. The purpose of this retrospective study was to compare the treatment duration, financial costs, and postdelivery adjustments of CAD-CAM and conventional removable complete dentures.Material and methods. Thirty-two edentulous participants (16 women, 16 men; age 35-85 years) who had received either CAD-CAM (n=16) or conventional (n=16) maxillary and mandibular removable complete dentures provided by prosthodontists with a minimum of 2 years of experience were evaluated. The CAD-CAM denture systems were either DDS-AV (AvaDent Digital Dental Solutions) (n=11) or DD-IV (Wieland Digital Denture) (n=5). The total treatment period (days) was recorded at 3 different time points (T0: preliminary alginate impression; T1: denture delivery; T2: last scheduled postdelivery adjustment). Adjustments during the follow-up (after T2) were noted and included the removal of areas of excessive pressure, relining, or repairs. The costs of the dental treatment and the laboratory fees were calculated. The Wilcoxon rank sum tests were used for statistical analysis (a=.05).Results. No statistically significant difference regarding the treatment duration between digitally and conventionally fabricated removable complete dentures was found: T0-T1 (P=.889); T1-T2 (P=.675); T2- T3 (P=.978). No significant difference was found in the number adjustments for areas of excessive pressure, relines, or repairs (P=.757, P=1.000, P=1.000) during the period. Laboratory costs of CAD -CAM removable complete dentures were significantly lower than those of conventional removable complete dentures (P<.001), but clinical fees were similar between groups (P=.596), resulting in a reduction in the overall total costs for the CAD-CAM removable complete dentures (P=.011). Regarding the number of clinical visits, neither the group (conventional/CAD-CAM (P=.945)/DDS-AV/ DD-IV [P=.848]) nor the interaction group (conventional/CAD-CAM and DDS-AV/DD-IV)/period (P=.084/P=.171) showed any significant differences.Conclusions. CAD-CAM removable complete dentures can be considered a viable alternative to conventional removable complete dentures regarding treatment duration, clinical and follow-up visits, adjustments, and maintenance requirements. (J Prosthet Dent 2022;128:390-5)
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [41] Management and clinical outcomes of cardiogenic shock in King Abdulaziz University Hospital A retrospective study
    Fida, Hamza L.
    Qutub, Mohammed A.
    Algazzar, Alaa S.
    AlDharrab, Abdulrahman S.
    Alnajjar, Terad A.
    Andijani, Anas M. A.
    Taiyeb, Ahmad M.
    SAUDI MEDICAL JOURNAL, 2023, 44 (05) : 479 - 485
  • [42] Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part I: Time efficiency of complete-arch digital scans versus conventional impressions
    Sailer, Irena
    Muhlemann, Sven
    Fehmer, Vincent
    Hammerle, Christoph H. F.
    Benic, Goran I.
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01): : 69 - 75
  • [43] Occlusal Pressure Analysis of Complete Dentures after Microwave Disinfection: A Clinical Study
    Manzolli Basso, Michael Frederico
    Giampaolo, Eunice Teresinha
    Vergani, Carlos Eduardo
    Pavarina, Ana Claudia
    Machado, Ana Lucia
    Jorge, Janaina Habib
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (07): : 606 - 610
  • [44] A retrospective study assessing the clinical outcomes and costs of acute hepatitis A in Cape Town, South Africa
    Jenna Patterson
    Susan Cleary
    Sheetal P. Silal
    Gregory D. Hussey
    Annabel Enoch
    Stephen Korsman
    Elizabeth Goddard
    Mashiko Setshedi
    Wendy C. Spearman
    Benjamin M. Kagina
    Rudzani Muloiwa
    BMC Infectious Diseases, 22
  • [45] A retrospective study assessing the clinical outcomes and costs of acute hepatitis A in Cape Town, South Africa
    Patterson, Jenna
    Cleary, Susan
    Silal, Sheetal P.
    Hussey, Gregory D.
    Enoch, Annabel
    Korsman, Stephen
    Goddard, Elizabeth
    Setshedi, Mashiko
    Spearman, Wendy C.
    Kagina, Benjamin M.
    Muloiwa, Rudzani
    BMC INFECTIOUS DISEASES, 2022, 22 (01)
  • [46] Clinical study of the biofilm of implant-supported complete dentures in healthy patients
    Matthes de Freitas Pontes, Karina
    Fontenelle, Iana Sa de Oliveira
    do Nascimento, Cassio
    Oliveira, Viviane de Cassia
    Albuquerque Garcia, Bruna
    Silva, Paulo Goberlanio de Barros
    Henrique, Larissa de Souza
    de Souza, Katherine Milhomem
    Pontes, Cassio de Barros
    GERODONTOLOGY, 2022, 39 (02) : 148 - 160
  • [47] Influence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Study
    Manzolli Basso, Michael Frederico
    Giampaolo, Eunice Teresinha
    Vergani, Carlos Eduardo
    Machado, Ana Lucia
    Pavarina, Ana Claudia
    Compagnoni, Marco Antonio
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 318 - 320
  • [48] Infographic: Trauma Triage Clinic reduces unnecessary fracture clinic attendances and costs with comparable clinical outcomes
    Mackenzie, S. P.
    Carter, T. H.
    Jefferies, J. G.
    Wilby, J. B. J.
    Hall, P.
    Duckworth, A. D.
    Keating, J. F.
    White, T. O.
    BONE & JOINT JOURNAL, 2018, 100B (07): : 957 - 958
  • [49] Masticatory Efficiency in Implant-Supported Fixed Complete Dentures Compared with Conventional Dentures: A Randomized Clinical Trial by Color-Mixing Analysis Test
    Jasser, Elie
    Salami, Zahraa
    El Hage, Fady
    Makzoume, Joseph
    Boulos, Paul Jamil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (03) : 599 - 606
  • [50] Comparison of Masticatory Efficiency and Patient Satisfaction of Injection-Molded Conventional Complete Dentures and Biofunctional Prosthetic System Dentures: A Parallel Randomized Clinical Trial
    Vivek, Shankar Piramanayagam
    Jagdish, Sivanesan Karthikeyan
    Murugesan, Krishnan
    Peter, John
    Arunkumar, Chithambaradhas Sivakala
    Muthukumar, Balasubramaniam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)