Clinical outcomes and costs of conventional and digital complete dentures in a university clinic: A retrospective study

被引:17
|
作者
Arakawa, Itsuka [1 ]
Husain, Nadin Al-Haj [2 ]
Srinivasan, Murali [3 ,6 ]
Maniewicz, Sabrina [4 ]
Abou-Ayash, Samir [5 ]
Schimmel, Martin [6 ,7 ,8 ]
机构
[1] Nippon Dent Univ, Comprehens Dent Care Unit, Niigata Hosp, Niigata, Japan
[2] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[3] Univ Zurich, Ctr Dent Med, Clin Gen Special Care & Geriatr Dent, Zurich, Switzerland
[4] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Geneva, Switzerland
[5] Univ Bern, Sch Dent, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dept DIRecD, Bern, Switzerland
[6] Univ Geneva, Univ Clin Dent Med, Div Gerodontol & Removable Prosthodont, Extra muros, Geneva, Switzerland
[7] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[8] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 03期
关键词
CAD-CAM;
D O I
10.1016/j.prosdent.2020.12.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Scientific data analyzing the clinical outcomes and costs of complete dentures fabricated by using conventional and computer-aided design and computer-aided manufacturing (CAD-CAM) processes are lacking.Purpose. The purpose of this retrospective study was to compare the treatment duration, financial costs, and postdelivery adjustments of CAD-CAM and conventional removable complete dentures.Material and methods. Thirty-two edentulous participants (16 women, 16 men; age 35-85 years) who had received either CAD-CAM (n=16) or conventional (n=16) maxillary and mandibular removable complete dentures provided by prosthodontists with a minimum of 2 years of experience were evaluated. The CAD-CAM denture systems were either DDS-AV (AvaDent Digital Dental Solutions) (n=11) or DD-IV (Wieland Digital Denture) (n=5). The total treatment period (days) was recorded at 3 different time points (T0: preliminary alginate impression; T1: denture delivery; T2: last scheduled postdelivery adjustment). Adjustments during the follow-up (after T2) were noted and included the removal of areas of excessive pressure, relining, or repairs. The costs of the dental treatment and the laboratory fees were calculated. The Wilcoxon rank sum tests were used for statistical analysis (a=.05).Results. No statistically significant difference regarding the treatment duration between digitally and conventionally fabricated removable complete dentures was found: T0-T1 (P=.889); T1-T2 (P=.675); T2- T3 (P=.978). No significant difference was found in the number adjustments for areas of excessive pressure, relines, or repairs (P=.757, P=1.000, P=1.000) during the period. Laboratory costs of CAD -CAM removable complete dentures were significantly lower than those of conventional removable complete dentures (P<.001), but clinical fees were similar between groups (P=.596), resulting in a reduction in the overall total costs for the CAD-CAM removable complete dentures (P=.011). Regarding the number of clinical visits, neither the group (conventional/CAD-CAM (P=.945)/DDS-AV/ DD-IV [P=.848]) nor the interaction group (conventional/CAD-CAM and DDS-AV/DD-IV)/period (P=.084/P=.171) showed any significant differences.Conclusions. CAD-CAM removable complete dentures can be considered a viable alternative to conventional removable complete dentures regarding treatment duration, clinical and follow-up visits, adjustments, and maintenance requirements. (J Prosthet Dent 2022;128:390-5)
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [1] Clinical Performance of Complete Dentures: A Retrospective Study
    Dorner, Stefan
    Zeman, Florian
    Koller, Michael
    Lang, Reinhold
    Handel, Gerhard
    Behr, Michael
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (05) : 410 - 417
  • [2] Digital vs. conventional removable complete dentures: A retrospective study on clinical effectiveness and cost-efficiency in edentulous patients Clinical effectiveness and cost-efficiency analysis of digital dentures
    Casucci, Alessio
    Cagidiaco, Edoardo Ferrari
    Verniani, Giulia
    Ferrari, Marco
    Borracchini, Andrea
    JOURNAL OF DENTISTRY, 2025, 153
  • [3] Digital versus conventional complete dentures: A randomized, controlled, blinded study
    Peroz, Simon
    Peroz, Ingrid
    Beuer, Florian
    Sterzenbach, Guido
    von Stein-Lausnitz, Manja
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 956 - 963
  • [4] Patients' Profiles and Perceptions of Complete Dentures in a University Dental Clinic
    Divaris, Kimon
    Ntounis, Athanasios
    Marinis, Aristotelis
    Polyzois, Gregory L.
    Polychronopoulou, Argy
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (02) : 145 - 147
  • [5] Patient-reported outcome and cost-effectiveness analysis of milled and conventionally fabricated complete dentures in a university clinic: A retrospective study
    Otake, Ryosuke
    Kanazawa, Manabu
    Iwaki, Maiko
    Soeda, Yumika
    Hada, Tamaki
    Katheng, Awutsadaporn
    Komagamine, Yuriko
    Minakuchi, Shunsuke
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (02): : 227 - 232
  • [6] Retrospective Comparison of Postinsertion Maintenances Between Conventional and 3D Printed Complete Dentures Fabricated in a Predoctoral Clinic
    Kim, Tae Hyung
    Huh, Jung Bo
    Lee, Janet
    Bae, Eun-Bin
    Park, Cheryl J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 : 158 - 162
  • [7] Clinical performance of computer-engineered complete dentures: a retrospective pilot study
    Schlenz, Maximiliane Amelie
    Schmidt, Alexander
    Woestmann, Bernd
    Rehmann, Peter
    QUINTESSENCE INTERNATIONAL, 2019, 50 (09): : 706 - 711
  • [8] Evaluating Post-Insertion Complications and Patient Satisfaction of Conventional Complete Dentures: A Retrospective Study
    Sharma, Lavanya Ajay
    Yaparathna, Navodika
    Cheruka, Nithya
    Shao, Peng
    Abuzar, Menaka
    ORAL, 2024, 4 (03): : 362 - 375
  • [9] Duplicating Complete Dentures with Conventional and Digital Methods: Comparisons of Trueness and Efficiency
    Chen, Li
    Li, Deli
    Zhou, Jianfeng
    Lin, Wei-Shao
    Tan, Jianguo
    DENTISTRY JOURNAL, 2022, 10 (03)
  • [10] Simplified versus conventional complete dentures: A randomized crossover clinical trial
    Ereifej, Nadia S.
    Oweis, Yara G.
    El Manaseer, Wijdan
    Al Omoush, Salah
    Abu Awwad, Motasum
    Sartawi, Samiha
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (01): : 50 - 55