The Impact of Distal Stent Graft-Induced New Entry on Aortic Remodeling of Chronic Type B Dissection

被引:29
|
作者
Huang, Chun-Yang
Hsu, Hung-Lung
Chen, Po-Lin
Chen, I-Ming
Hsu, Chiao-Po
Shih, Chun-Che
机构
[1] Taipei Vet Gen Hosp, Div Cardiovasc Surg, Dept Surg, Taipei, Taiwan
[2] Natl Yang Ming Univ, Inst Clin Med, Sch Med, Taipei, Taiwan
[3] Far Eastern Mem Hosp, Div Cardiovasc Surg, Taipei, Taiwan
来源
ANNALS OF THORACIC SURGERY | 2018年 / 105卷 / 03期
关键词
STEEL-BASED DEVICE; ENDOVASCULAR REPAIR; OUTCOMES;
D O I
10.1016/j.athoracsur.2017.08.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
C Background. In chronic type B aortic dissection, late distal stent graft-induced new entry (SINE) has a possible negative role in long-term aortic remodeling. This study aimed to investigate the impact of SINE occurrence on survival by evaluating true and false lumen remodeling in thoracic and abdominal segments at midterm surveillance. Methods. This study enrolled 65 patients with chronic type B aortic dissection (DeBakey type IIIb), who had received hybrid thoracic endovascular aortic repair (TEVAR) and had completed surveillance for at least 3 years. The 3-year survival rate was 84.7%. The patients were classified into non-SINE (n = 47) and SINE (n = 18) groups. Serial computed tomography scans were used to analyze volumetric change, true and false lumens, and thrombus volume from arch to aortic bifurcation level. Results. The SINE event occurred at a median of 22.5 months. In the SINE group, there was a significant interruption of the abdominal true lumen expansion in the second year (median 0.01 [interquartile range (IQR), -0.03 to 0.12] in the non-SINE group versus median -0.04 [IQR, -0.12 to 0.04] in the SINE group; p = 0.014). There was a significantly worse thoracic false lumen remodeling in the SINE group compared with the non-SINE group in the third year after the SINE event occurred (median 0 [IQR, -0.09 to 0.05] in the non-SINE group versus median 0.06 [IQR, 0 to 0.13] in the SINE group; p = 0.038). Conclusions. For chronic aortic dissection, late occurrence of distal SINE could influence abdominal true lumen expansion and thoracic false lumen shrinkage. Early reintervention for distal SINE could improve aortic remodeling in chronic aortic dissection. (C) 2018 by The Society of Thoracic Surgeons
引用
收藏
页码:785 / 793
页数:9
相关论文
共 50 条
  • [41] Stent graft-induced new entry tear (SINE): Intentional and NOT
    Hughes, G. Chad
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (01): : 101 - +
  • [42] Longitudinal morphological changes of the aorta and the endograft position before and after distal stent graft-induced new entry in aortic dissections
    Andic, Mateja
    Mustafi, Migdat
    Bonorden, Constantin
    Groezinger, Gerd
    Artzner, Christoph
    Schlensak, Christian
    Lescan, Mario
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 63 (01)
  • [43] Early Prediction of Distal Stent Graft-Induced New Entry after Thoracic Endovascular Aortic Repair with Computational Fluid Dynamics
    School of Medical Technology, Beijing Institute of Technology, China
    ACM Int. Conf. Proc. Ser., 1600, (84-90):
  • [44] Early Experience With a Novel Dissection-Specific Stent-Graft to Prevent Distal Stent-Graft-Induced New Entry Tears After Thoracic Endovascular Repair of Chronic Type B Aortic Dissections
    Burdess, Anne
    D'Oria, Mario
    Mani, Kevin
    Tegler, Gustaf
    Lindstrom, David
    Mogensen, John
    Koelbel, Tilo
    Wanhainen, Anders
    ANNALS OF VASCULAR SURGERY, 2022, 81 : 36 - 47
  • [45] The role of aorta distal to stent in the occurrence of distal stent graft-induced new entry tear: A computational fluid dynamics and morphological study
    Luan, Jingyang
    Qiao, Yonghui
    Mao, Le
    Fan, Jianren
    Zhu, Ting
    Luo, Kun
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 166
  • [46] Distal Stent Graft-Induced New Entry After TEVAR or FET: Insights Into a New Disease From EuREC
    Czerny, Martin
    Eggebrecht, Holger
    Rousseau, Herve
    Mouroz, Paul Revel
    Janosi, Rolf-Alexander
    Lescan, Mario
    Schlensak, Christian
    Boeckler, Dittmar
    Ante, Marius
    Weijde, Emma Vdr
    Heijmen, Robin
    Eckstein, Hans Henning
    Reutersberg, Benedikt
    Trimarchi, Santi
    Schmidli, Juerg
    Wyss, Thomas
    Frey, Romina
    Makaloski, Vladimir
    Brunkwall, Jan
    Mylonas, Spyridon
    Szeberin, Zoltan
    Klocker, Josef
    Gottardi, Roman
    Schusterova, Ingrid
    Morlock, Julia
    Berger, Tim
    Beyersdorf, Friedhelm
    Rylski, Bartosz
    ANNALS OF THORACIC SURGERY, 2020, 110 (05): : 1494 - 1500
  • [47] Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection
    Huang, Chun-Yang
    Weng, Shih-Hsien
    Weng, Chi-Feng
    Chen, Wei-Yuan
    Chen, I-Ming
    Hsu, Chiao-Po
    Shih, Chun-Che
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (03): : 623 - 630
  • [48] Distal stent graft-induced new entry (dSINE) after frozen elephant trunk: a scoping review
    Murana, Giacomo
    Costantino, Antonino
    Campanini, Francesco
    Fiaschini, Costanza
    Buia, Francesco
    Mariani, Carlo
    Leone, Alessandro
    Di Marco, Luca
    Pacini, Davide
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2023, 13 (02) : 408 - 417
  • [49] Stent-graft induced new entry tears after type B aortic dissection: how to treat and how to prevent?
    Burdess, Anne
    Mani, Kevin
    Tegler, Gustaf
    Wanhainen, Anders
    JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (06): : 789 - 796
  • [50] Incidence of Distal Stent Graft Induced New Entry vs. Aortic Remodeling Associated With Frozen Elephant Trunk
    Jubouri, Matti
    Kayali, Fatima
    Saha, Priyanshu
    Ansari, Daniyal M.
    Rezaei, Yousef
    Tan, Sven Z. C. P.
    Mousavizadeh, Mostafa
    Hosseini, Saeid
    Mohammed, Idhrees
    Bashir, Mohamad
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9