Comprehensive methodology for commissioning modern 3D-image-based treatment planning systems for high dose rate gynaecological brachytherapy: A review

被引:3
|
作者
Kanani, Abolfazl [1 ]
Owrangi, Amir M. [2 ]
Mosleh-Shirazi, Mohammad Amin [1 ,3 ]
机构
[1] Shiraz Univ Med Sci, Ionizing & Nonionizing Radiat Protect Res Ctr, Sch Paramed Sci, Shiraz, Iran
[2] UT Southwestern Med Ctr, Dept Radiat Oncol, 2280 Inwood Rd,EC2-242, Dallas, TX 75235 USA
[3] Shiraz Univ Med Sci, Sch Med, Dept Radiooncol, Phys Unit, Shiraz 7193613311, Iran
关键词
HDR; Brachytherapy; TPS; Qualityassurance (QA); Commissioning; COLLAPSED-CONE ENGINE; SOCIETY CONSENSUS GUIDELINES; CERVIX CANCER BRACHYTHERAPY; LOCALLY ADVANCED-CARCINOMA; QUALITY-ASSURANCE; INTRACAVITARY BRACHYTHERAPY; AMERICAN BRACHYTHERAPY; TREATMENT DELIVERY; VOLUME PARAMETERS; RECOMMENDATIONS;
D O I
10.1016/j.ejmp.2020.07.031
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Correct commissioning of treatment planning systems (TPSs) is important for reducing treatment failure events. There is currently no comprehensive and robust methodology available for TPS commissioning in modern brachytherapy. This review aimed to develop a comprehensive template for commissioning modern 3D-image-based brachytherapy TPSs for high dose rate (HDR) gynaecological applications. Methods: The literature relevant to TPS commissioning, including both external beam radiation therapy (EBRT) and brachytherapy, as well as guidelines by the International Atomic Energy Agency (IAEA), the American Association of Physicists in Medicine (AAPM), and the European Society for Radiotherapy and Oncology (ESTRO) were searched, studied and appraised. The applied relevant EBRT TPS commissioning tests were applied to brachytherapy. The developed template aimed to cover all dosimetric and non-dosimetric issues. Results: The essential commissioning items could be categorized into six parts: geometry, dose calculation, plan evaluation tools, plan optimization, TPS output, and end-to-end verification. The final template consists of 43 items. This paper presents the purpose and role of each test, as well as tolerance limits, to facilitate the use of the template. Conclusion: The information and recommendations available in a collection of publications over many years have been reviewed in order to develop a comprehensive template for commissioning complex modern 3D-image-based brachytherapy TPSs for HDR gynaecological applications. The up-to-date and concise information contained in the template can aid brachytherapy physicists during TPS commissioning as well as devising a regular quality assurance program and allocation of time and resources.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 50 条
  • [21] Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms
    Moura, Eduardo S.
    Micka, John A.
    Hammer, Cliff G.
    Culberson, Wesley S.
    DeWerd, Larry A.
    Rostelato, Maria Elisa C. M.
    Zeituni, Carlos A.
    MEDICAL PHYSICS, 2015, 42 (04) : 1566 - 1574
  • [22] Image-based 3D dosimetric studies with high dose rate intracavitary brachytherapy of cervical cancer
    Chakravarty, N.
    Semwal, M. K.
    Trivedi, G.
    Suhag, V
    Jain, M.
    Sharma, N.
    Vashisth, R. S.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (03) : 277 - 280
  • [23] A 3D imaging technique for brachytherapy planning and treatment in a single high dose rate (HDR) radiation operating suite
    Law, N. R.
    Loblaw, A.
    Morton, G.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 : S47 - S47
  • [24] A user-oriented procedure for the commissioning and quality assurance testing of treatment planning system dosimetry in high-dose-rate brachytherapy
    Peppa, Vasiliki
    Pantelis, Evaggelos
    Pappas, Eleftherios
    Lahanas, Vasileios
    Loukas, Constantinos
    Papagiannis, Panagiotis
    BRACHYTHERAPY, 2016, 15 (02) : 252 - 262
  • [25] Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms
    Rivard, Mark J.
    Beaulieu, Luc
    Mourtada, Firas
    MEDICAL PHYSICS, 2010, 37 (06) : 2645 - 2658
  • [26] Evaluation of CT-Based High Dose Rate Brachytherapy Treatment Planning in Nasopharynx Using Dose Volume Indices
    Senthil, G.
    Muthulingam, S.
    Shankar, V.
    Prajapathi, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [27] Characterization of a 3D Gamma Camera to Image the High-Dose-Rate Brachytherapy Source
    Jones, K. C.
    Liao, Y.
    Grelewicz, Z. R.
    Turian, J. V.
    MEDICAL PHYSICS, 2024, 51 (10) : 7746 - 7746
  • [28] Dosimetric Evaluation Of PLATO And ONCENTRA Treatment Planning Systems For High Dose Rate (HDR) Brachytherapy Gynecological Treatments
    Singh, Hardev
    Herman, Tania De La Fuente
    Showalter, Barry
    Thompson, Spencer J.
    Syzek, Elizabeth J.
    Herman, Terence
    Ahmad, Salahuddin
    MEDICAL PHYSICS, 2012, 1494 : 70 - 72
  • [29] Dosimetry and Early Clinical Outcomes of 3D Treatment Planning for High Dose Rate Brachytherapy of Medically Inoperable Endometrial Cancer
    Olson, A. C.
    Beriwal, S.
    Kim, H.
    Houser, C.
    Wegner, R. E.
    Heron, D. E.
    Richard, S. D.
    Kelley, J. L.
    Edwards, R. P.
    Sukumvanich, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S475 - S475
  • [30] 2D ICRU-BASED VERSUS 3D IMAGE-GUIDED PLANNING IN HIGH DOSE RATE BRACHYTHERAPY FOR CERVICAL CANCER - A STUDY ON EFFICACY AND TREATMENT-RELATED TOXICITIES
    Faye, Mame Daro
    Araujo, Mariana Petruccelli
    Alrabiah, Khalid
    Wissing, Michel D.
    Alfieri, Joanne
    RADIOTHERAPY AND ONCOLOGY, 2020, 150 : S45 - S45