Instantaneous d frame driven shunt active filter for harmonics and reactive power mitigation using Xilinx System Generator

被引:4
|
作者
Sriranjani, Ramakrishnan [1 ]
Jayalalitha, Subbaiah [2 ]
机构
[1] SASTRA Deemed Univ, EEED, SEEE, Thanjavur, Tamil Nadu, India
[2] SASTRA Deemed Univ, EIED, SEEE, Thanjavur, Tamil Nadu, India
关键词
Harmonics; Reactive power; Shunt active filter; MATLAB; Xilinx system generator;
D O I
10.1016/j.asej.2018.02.005
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Instantaneous d frame driven Shunt active filter (SAF) alleviate harmonics and reactive power. This control algorithm evolved from elemental synchronous reference frame engenders the fundamental reference signal from the load current with a phase shift of zero angle. The proposed algorithm is tested in harmonic load and reactive load and it is verified by implementing the model in MATLAB Xilinx system generator. The comparison study was carried out for the proposed algorithm and conventional algorithm and the results are presented in this paper. (C) 2018 The Authors. Published by Elsevier B.V. on behalf of Faculty of Engineering, Ain Shams University.
引用
收藏
页码:15 / 22
页数:8
相关论文
共 50 条
  • [31] IMPLEMENTATION OF A SHUNT ACTIVE FILTER USING THE THEORY OF GENERALIZED INSTANTANEOUS POWER
    Silva, Paulo Vitor
    Pinheiro, Ricardo Ferreira
    Aguiar, Marcos V.
    Junior, Luciano P.
    Salazar, Andres Ortiz
    Cunha, Caio D.
    XI BRAZILIAN POWER ELECTRONICS CONFERENCE (COBEP 2011), 2011, : 782 - 787
  • [32] Sliding mode control applied to a 3Φ shunt active power filter using compensation with instantaneous reactive power theory
    Cárdenas, V
    Vazquez, N
    Hernández, C
    PESC 98 RECORD - 29TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1 AND 2, 1998, : 236 - 241
  • [33] An Improved SVPWM based Shunt Active Power Filter for Compensation of Power System Harmonics
    Varaprasad, O. V. S. R.
    Sarma, D. V. S. S. Siva
    2014 IEEE 16TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2014, : 571 - 575
  • [34] Application of Shunt Active Power Filter to Isolated Synchronous Generator System
    Surgevil, Tolga
    Akpinar, Eyup
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 227 - +
  • [35] Mitigation Of Harmonics Current Using Different Control Algorithms Of Shunt Active Power Filter For Non-Linear Loads
    Kamel, Khechiba
    Laid, Zellouma
    Abdallah, Kouzou
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON APPLIED SMART SYSTEMS (ICASS), 2018,
  • [36] Compensation of harmonics using a shunt active power filter powered by a photovoltaic source
    Cherfi, Mohamed Khelil
    Gacemi, Abderrezak
    Morsli, Abdelkader
    Tlemcani, Abdelhalim
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (06): : 69 - 73
  • [37] Elimination of Harmonics Using Bacterial Foraging Optimized Shunt Active Power Filter
    Sharaf, Anju
    Pandey, Rahul
    Singh, Mahesh
    Jhapte, Rajkumar
    2017 RECENT DEVELOPMENTS IN CONTROL, AUTOMATION AND POWER ENGINEERING (RDCAPE), 2017, : 354 - 359
  • [38] Harmonic mitigation in three phase three wire system using shunt active power filter
    Lakra, Rajeev
    Kasireddy, Idamakanti
    Singh, Arun Kumar
    2018 INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN ELECTRICAL, ELECTRONICS & COMMUNICATION ENGINEERING (ICRIEECE 2018), 2018, : 2753 - 2756
  • [39] The Simplified Control of Three-Phase Four-Leg Shunt Active Power Filter for Harmonics Mitigation, Load Balancing and Reactive Power Compensation
    Po-Ngam, Sakorn
    2014 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2014,
  • [40] A Study of a Three-Phase Four-Wire Shunt Active Power Filter for Harmonics Mitigation
    Ayala Maciel, Luis Fernando
    Monroy Morales, Jose Luis
    Marroquin Pimentel, Juan Gabriel
    Campos Gaona, David
    2018 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC), 2018,