Dynamic Contrast-Enhanced MRI Evaluation of Cerebral Cavernous Malformations

被引:28
|
作者
Hart, Blaine L. [1 ]
Taheri, Saeid [2 ]
Rosenberg, Gary A. [3 ]
Morrison, Leslie A. [3 ]
机构
[1] Univ New Mexico, Dept Radiol, Albuquerque, NM 87131 USA
[2] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[3] Univ New Mexico, Dept Neurol, Albuquerque, NM 87131 USA
基金
美国国家卫生研究院;
关键词
MRI dynamic contrast enhanced; Brain/brain stem; Genetic defects; BLOOD-BRAIN-BARRIER; TRANSFER CONSTANTS; NATURAL-HISTORY; PERMEABILITY; INTEGRITY;
D O I
10.1007/s12975-013-0285-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The aim of this study is to quantitatively evaluate the behavior of CNS cavernous malformations (CCMs) using a dynamic contrast-enhanced MRI (DCEMRI) technique sensitive for slow transfer rates of gadolinium. The prospective study was approved by the institutional review board and was HIPPA compliant. Written informed consent was obtained from 14 subjects with familial CCMs (4 men and 10 women, ages 22-76 years, mean 48.1 years). Following routine anatomic MRI of the brain, DCEMRI was performed for six slices, using T1 mapping with partial inversion recovery (TAPIR) to calculate T1 values, following administration of 0.025 mmol/kg gadolinium DTPA. The transfer rate (Ki) was calculated using the Patlak model, and Ki within CCMs was compared to normal-appearing white matter as well as to 17 normal control subjects previously studied. All subjects had typical MRI appearance of CCMs. Thirty-nine CCMs were studied using DCEMRI. Ki was low or normal in 12 lesions and elevated from 1.4 to 12 times higher than background in the remaining 27 lesions. Ki ranged from 2.1E-6 to 9.63E-4 min(-1), mean 3.55E-4. Normal-appearing white matter in the CCM patients had a mean Ki of 1.57E-4, not statistically different from mean WM Ki of 1.47E-4 in controls. TAPIR-based DCEMRI technique permits quantifiable assessment of CCMs in vivo and reveals considerable differences not seen with conventional MRI. Potential applications include correlation with biologic behavior such as lesion growth or hemorrage, and measurement of drug effects.
引用
收藏
页码:500 / 506
页数:7
相关论文
共 50 条
  • [41] Comparison of Denoising Methods On Dynamic Contrast-Enhanced MRI
    He, R.
    Ding, Y.
    Wahid, K.
    Mohamed, A.
    McDonald, B.
    Naser, M.
    Wang, J.
    Hutcheson, K.
    Fuller, C.
    Lai, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E777 - E778
  • [42] Blind Deconvolution in Dynamic Contrast-Enhanced MRI and Ultrasound
    Jirik, Radovan
    Soucek, Karel
    Mezl, Martin
    Bartos, Michal
    Drazanova, Eva
    Drafi, Frantisek
    Grossova, Lucie
    Kratochvila, Jiri
    Macicek, Ondrej
    Nylund, Kim
    Hampl, Ales
    Gilja, Odd Helge
    Taxt, Torfinn
    Starcuk, Zenon, Jr.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4276 - 4279
  • [43] Dynamic contrast-enhanced MRI for prostate cancer localization
    Jackson, A. S. N.
    Reinsberg, S. A.
    Sohaib, S. A.
    Charles-Edwards, E. M.
    Jhavar, S.
    Christmas, T. J.
    Thompson, A. C.
    Bailey, M. J.
    Corbishley, C. M.
    Fisher, C.
    Leach, M. O.
    Dearnaley, D. P.
    BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (974): : 148 - 156
  • [44] Neurovascular MRI with dynamic contrast-enhanced subtraction angiography
    S. C. Coley
    J. M. Wild
    I. D. Wilkinson
    P. D. Griffiths
    Neuroradiology, 2003, 45 : 843 - 850
  • [45] Physiological modelling of dynamic contrast-enhanced MRI in COPD
    Hubbard, Penny
    Parker, Geoff
    Singh, Dave
    Vestbo, Jorgen
    Olsson, Lars
    Wigstrom, Lars
    Young, Simon
    Bondesson, Eva
    Naish, Josephine
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [46] DYNAMIC CONTRAST-ENHANCED MRI TO ASSESS THE MICROVASCULATURE IN IPF
    Montesi, Sydney
    Zhou, Iris Yuwen
    Digumarthy, Subba
    Seethamraju, Ravi Teja
    Caravan, Peter
    CHEST, 2019, 156 (04) : 2268A - 2268A
  • [47] Testicular Torsion and Necrosis on Dynamic Contrast-Enhanced MRI
    Venkatraman Indiran
    Indian Journal of Surgery, 2023, 85 : 195 - 196
  • [48] Fundamentals of Tracer Kinetics for Dynamic Contrast-Enhanced MRI
    Koh, Tong San
    Bisdas, Sotirios
    Koh, Dow Mu
    Thng, Choon Hua
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (06) : 1262 - 1276
  • [49] A New Denoising Method for Dynamic Contrast-Enhanced MRI
    Gal, Yaniv
    Mehnert, Andrew
    Bradley, Andrew
    McMahon, Kerry
    Kennedy, Dominic
    Crozier, Stuart
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 847 - +
  • [50] Dynamic Contrast-Enhanced MRI of OATP Dysfunction in Diabetes
    Shuboni-Mulligan, Dorela D.
    Parys, Maciej
    Blanco-Fernandez, Barbara
    Mallett, Christiane L.
    Schnegelberger, Regina
    Takada, Marilia
    Chakravarty, Shatadru
    Hagenbuch, Bruno
    Shapiro, Erik M.
    DIABETES, 2019, 68 (02) : 271 - 280