REGIONAL VENTILATION DELAY INHOMOGENEITY MEASURED BY ELECTRICAL IMPEDANCE TOMOGRAPHY DURING PEEP TITRATION IN HEALTHY LUNGS AND DIFFERENT MODELS OF LUNG INJURY

被引:0
|
作者
Muders, T. [1 ]
Huckauf, S. [2 ]
Reske, A. [2 ]
Lutterkord, M. [2 ]
Buchloh, D. [2 ]
Luepschen, H. [1 ]
Putensen, C. [1 ]
Wrigge, H. [2 ]
机构
[1] Univ Bonn, Dept Anesthesiol & Intens Care Med, Bonn, Germany
[2] Univ Leipzig, Dept Anesthesiol & Intens Care Med, D-04109 Leipzig, Germany
关键词
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
0127
引用
收藏
页码:S40 / S40
页数:1
相关论文
共 50 条
  • [21] Measurement of Electrical Impedance Tomography-Based Regional Ventilation Delay for Individualized Titration of End-Expiratory Pressure
    Muders, Thomas
    Hentze, Benjamin
    Kreyer, Stefan
    Wodack, Karin Henriette
    Leonhardt, Steffen
    Hedenstierna, Goeran
    Wrigge, Hermann
    Putensen, Christian
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [22] The Dark Side of the Lung Unveiling Regional Lung Ventilation with Electrical Impedance Tomography
    Canet, Jaume
    Gallart, Lluis
    ANESTHESIOLOGY, 2012, 116 (06) : 1186 - 1188
  • [23] Topographical distribution of regional lung ventilation determined by electrical impedance tomography
    Frerichs, I
    Hintz, J
    Herrmann, P
    Weisser, G
    Hahn, G
    Quintel, M
    Hellige, G
    INTENSIVE CARE MEDICINE, 2001, 27 : S259 - S259
  • [24] Imbalances in regional lung ventilation - A validation study on electrical impedance tomography
    Victorino, JA
    Borges, JB
    Okamoto, VN
    Matos, GFJ
    Tucci, MR
    Caramez, MPR
    Tanaka, H
    Sipmann, FS
    Santos, DCB
    Barbas, CSV
    Carvalho, CRR
    Amato, MBP
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (07) : 791 - 800
  • [25] Assessing effects of PEEP and global expiratory lung volume on regional electrical impedance tomography
    Markhorst, D.G.
    Groeneveld, A.B.J.
    Heethaar, R.M.
    Zonneveld, E.
    Van Genderingen, H.R.
    Journal of Medical Engineering and Technology, 2009, 33 (04): : 281 - 287
  • [26] A lung area estimation method for analysis of ventilation inhomogeneity based on electrical impedance tomography
    Zhao, Zhanqi
    Steinmann, Daniel
    Mueller-Zivkovic, Danijela
    Martin, Joerg
    Frerichs, Inez
    Guttmann, Josef
    Moeller, Knut
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (02) : 171 - 182
  • [27] Regional lung volume during high-frequency oscillatory ventilation by electrical impedance tomography
    van Genderingen, HR
    van Vught, AJ
    Jansen, JRC
    CRITICAL CARE MEDICINE, 2004, 32 (03) : 787 - 794
  • [28] Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography - a randomized controlled trial
    Weber, Jonas
    Gutjahr, Jan
    Schmidt, Johannes
    Lozano-Zahonero, Sara
    Borgmann, Silke
    Schumann, Stefan
    Wirth, Steffen
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [29] Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography – a randomized controlled trial
    Jonas Weber
    Jan Gutjahr
    Johannes Schmidt
    Sara Lozano-Zahonero
    Silke Borgmann
    Stefan Schumann
    Steffen Wirth
    BMC Anesthesiology, 20
  • [30] PEEP guided by electrical impedance tomography during one-lung ventilation in elderly patients undergoing thoracoscopic surgery
    Liu, Kun
    Huang, Chengya
    Xu, Meiying
    Wu, Jingxiang
    Frerichs, Inez
    Moeller, Knut
    Zhao, Zhanqi
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (23)