Audible noise of transmission lines caused by the corona effect: Analysis, modelling, prediction

被引:20
|
作者
Engel, Z
Wszolek, T
机构
[1] Mechanics and Vibroacoustics Dept., Tech. Univ. of Mining and Metallurgy, 30-059 Cracow
关键词
transmission lines; corona effect; audible noise;
D O I
10.1016/0003-682X(95)00041-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The paper presents the results of investigations of audible noise of high voltage transmission lines of alternating current (a.c. UHV) caused by the corona effect. The investigation results concern the 400 kV lines in two basic layouts existing in Poland: single horizontal and double vertical. Environmental investigations in real conditions were executed in a whole year cycle with the short-term method. Apart from the results of the environmental investigations the paper contains also the laboratory investigation results. The influence of constructional design and environmental parameters on the sound level distribution along a span was analysed. The influence of the conductor surface stare and weather conditions on the level and shape of the emitted audible noise spectrum was particularly taken into account. The evaluation of the influence of the line audible noise on the acoustic climate of the environment was carried out. The analysis of possibilities of the application of well known computational procedures to the prediction of the line audible noise caused by the corona effect in Polish conditions was executed and an original form of a line acoustic model with the audible noise prediction possibility as a function of rainfall was presented. (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:149 / 163
页数:15
相关论文
共 50 条
  • [41] Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line
    Liu, Yingyi
    Zhou, Lijuan
    Liu, Yuanqing
    Yuan, Haiwen
    Ji, Liang
    PHYSICS OF PLASMAS, 2017, 24 (11)
  • [42] AVAILABILITY OF CORONA CAGE FOR PREDICTING AUDIBLE NOISE GENERATED FROM HVDC TRANSMISSION-LINE
    NAKANO, Y
    SUNAGA, Y
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (02) : 1422 - 1431
  • [43] Test results and analysis of altitude-change effect on audible noise of AC corona occurring on conductors with corona-test cage
    Tang, Jian
    He, Jin-Liang
    Liu, Yun-Peng
    Yang, Ying-Jian
    Chen, Yu-Chao
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (04): : 105 - 111
  • [44] Corona discharge pulse pattern and audible noise on hybrid AC/DC transmission lines under electric field bias, ripple and ion coupling
    Hedtke, Soren
    Pfeiffer, Martin
    Franck, Christian M.
    JOURNAL OF ELECTROSTATICS, 2019, 102
  • [45] Generation Mechanism of Pure Tones of Audible Noise Caused by Single Corona Source Under AC Voltages
    Li X.
    Wang J.
    Cheng L.
    Lu T.
    Cui X.
    Xie H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (03): : 906 - 914
  • [46] Consistency analysis between the electric field and audible noise caused by UHV test line and UHV transmission line
    Lu, Yao
    Gan, Zhe-Yuan
    Chen, Yu-Chao
    Li, Ni
    Zha, Xian-Guang
    Gaodianya Jishu/High Voltage Engineering, 2011, 37 (02): : 354 - 360
  • [48] ASSESSING THE IMPACT OF AUDIBLE NOISE FROM AC TRANSMISSION-LINES - A PROPOSED METHOD
    KEAST, DN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (03): : 1021 - 1031
  • [49] ASSESSING THE IMPACT OF AUDIBLE NOISE FROM ac TRANSMISSION LINES: A PROPOSED METHOD.
    Keast, David N.
    1979,
  • [50] Calculation and Research of Audible Noise of AC Transmission Lines (Ⅰ) - Three-dimensional Distribution
    Xie G.
    Fu W.
    He W.
    Lan L.
    Wan B.
    Zhang Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2990 - 2998