Foot centre of pressure and ground reaction force during quadriceps resistance exercises; a comparison between force plates and a pressure insole system

被引:18
|
作者
Jonsson, Maria [1 ]
Munkhammar, Tobias [1 ]
Norrbrand, Lena [1 ]
Berg, Hans E. [2 ,3 ]
机构
[1] KTH Royal Inst Technol, Swedish Aerosp Physiol Ctr, Dept Environm Physiol, Berzelius V 13, S-17165 Solna, Sweden
[2] Karolinska Univ Hosp, Dept Ortopaed Surg, Stockholm, Sweden
[3] Karolinska Inst, CLINTEC, Unit Orthoped & Biotechnol, Stockholm, Sweden
关键词
Centre of pressure; Force plates; Pressure insoles; Leg press; Squat; VALIDITY; GAIT; WALKING;
D O I
10.1016/j.jbiomech.2019.03.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The study compared the centre of pressure measurements (COP) and vertical ground reaction forces (vGRF) from a pressure insole system to that from force plates (FP) during two flywheel quadriceps resistance exercises: leg press and squat. The comparison was performed using a motion capture system and simultaneous measurements of COP and vGRF from FP and insoles. At lower insole-vGRF (<250 N/insole) COP accuracy deteriorated and those data were excluded from further analysis. The insoles systematically displaced the COP slightly posteriorly and medially compared to the FP measurements. Pearson's coefficient of correlation (r) between insole- and FP-COP showed good agreement in both the anteroposterior (squat: r = 0.96, leg press: r = 0.97) and mediolateral direction (squat: r = 0.84, leg press: r = 0.90), whereas the root-mean-square errors (RMSE) were lower in the mediolateral (squat: 3.9 mm, leg press: 4.5 mm) than the anteroposterior (squat and leg press: 11.8 mm) direction. Vertical GRF was slightly overestimated by the insoles in leg press and RMSE were greater in leg press (8% of peak force) than in squat (6%). Overall, results were within the range of previous studies performed on gait. The strong agreement between insole and FP measurements indicates that insoles may replace FPs in field applications and biomechanical computations during resistance exercise, provided that the applied force is sufficient. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [31] Comparison of ground reaction force during different angle of squatting
    Dali, Sharikh
    Justine, Maria
    Ahmad, Hamid
    Othman, Zainal
    JOURNAL OF HUMAN SPORT AND EXERCISE, 2013, 8 (03): : 778 - 787
  • [32] Assessment of the horizontal, fore-aft component of the ground reaction force from insole pressure patterns by using artificial neural networks
    Savelberg, HHCM
    de Lange, ALH
    CLINICAL BIOMECHANICS, 1999, 14 (08) : 585 - 592
  • [33] Hip and knee kinematics, center of pressure position, and ground reaction force are associated with Achilles tendon force during jump landing
    Koshino, Yuta
    Ishida, Tomoya
    Taniguchi, Shohei
    Samukawa, Mina
    Kasahara, Satoshi
    Tohyama, Harukazu
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2024, 34 (01)
  • [34] Centre of pressure in dynamic posturography: a comparison among systems based on a pressure matrix and a force platform
    Rossi, S.
    Patane, F.
    Scalise, L.
    Marchionni, P.
    Cappa, P.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (01)
  • [35] Validation of Electronic Weighing Device for Vertical Ground Reaction Force and Centre of Pressure Measurement; and Clinical Metrics Derivation
    Yeo, Ying Heng
    Razali, Muhammad Fauzinizam
    Ripin, Zaidi Mohd
    J., Nur-Akasyah
    Ridzwan, Mohamad Ikhwan Zaini
    Tan, Alexander Wai Teng
    Tay, Jia Yi
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2024, 20 (04): : 888 - 901
  • [36] Estimating GRF(Ground Reaction Force) and Calibrating CoP(Center of Pressure) of an Insole Measured by an Low-Cost Sensor with Neural Network
    Choi, Ho Seon
    Shim, Myounghoon
    Lee, Chang Hee
    Baek, Yoon Su
    PROCEEDINGS 2018 IEEE 18TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2018, : 185 - 188
  • [37] Foot-ground reaction force during resistive exercise in parabolic flight
    Lee, SMC
    Cobb, K
    Loehr, JA
    Nguyen, D
    Schneider, SM
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2004, 75 (05): : 405 - 412
  • [38] A Development of Measurement System for Foot Pressure by Using Optical Force Sensors
    Yamada, Makoto
    Nagamune, Kouki
    2018 WORLD AUTOMATION CONGRESS (WAC), 2018, : 14 - 17
  • [39] Oxygen Uptake, Muscle Activity and Ground Reaction Force during Water Aerobic Exercises
    Alberton, C. L.
    Pinto, S. S.
    Cadore, E. L.
    Tartaruga, M. P.
    Kanitz, A. C.
    Antunes, A. H.
    Finatto, P.
    Kruel, L. F. M.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2014, 35 (14) : 1161 - 1169
  • [40] Estimate of floor reaction force vector using foot-pressure sensors
    Akita Prefectural R and D Center, 4-21 Sanuki, Araya-cho, Akita-shi, Akita, 010-1623, Japan
    Nihon Kikai Gakkai Ronbunshu C, 2008, 3 (749-751): : 749 - 751