Adsorptive stripping differential pulse voltammetric determination of metoprolol at Nafion-CNT-nano-composite film sensor

被引:37
|
作者
Desai, Purvi B. [1 ]
Srivastava, Ashwini K. [1 ]
机构
[1] Univ Mumbai, Dept Chem, Bombay 400098, Maharashtra, India
关键词
Metoprolol; Glassy carbon electrode; Nafion; Carbon nanotubes; Adsorptive differential pulse voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; WALLED CARBON NANOTUBES/NAFION; BETA-BLOCKERS; PASTE ELECTRODE; PHARMACEUTICAL-PREPARATIONS; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL-BEHAVIOR; GRAPHITE ELECTRODE; MASS-SPECTROMETRY; HUMAN URINE;
D O I
10.1016/j.snb.2012.10.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical method employing a Nafion-carbon nanotube-nano-composite film modified glassy carbon electrode (NAF-CNT-GCE) has been developed for the determination of metoprolol (MET). Cyclic voltammetry and adsorptive stripping differential pulse voltammetry were employed to study the electrochemical behavior of MET. Surface morphology of the electrodes was done using scanning electron microscopy. Studies reveal that the irreversible oxidation of MET was extremely facile on NAF-CNT-GCE. The optimized linear working range and detection limit (S/N = 3) are 7.02 x 10(-8) to 9.0 x 10(-6) M and 3.51 x 10(-8) M respectively. The analytical application of the modified GCE is demonstrated by determining MET in pharmaceutical formulations and biological fluids (serum and urine). The present sensor portrays certain advantages such as high sensitivity, simplicity, low detection limit and excellent reproducibility making the proposed method highly advantageous for MET determination. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:632 / 638
页数:7
相关论文
共 50 条
  • [31] Graphene-Nafion Composite Film Modified Electrode for Voltammetric Sensor for Determination of Dihydromyricetin
    Wang, Fei
    Yu, Xiang
    Li, Haojie
    Li, Ming
    Feng, Qimin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (08) : 1019 - 1026
  • [32] Nafion-mercury coated film electrode for the adsorptive stripping voltammetric determination of lead and cadmium in the presence of pyrogallol red
    Nagles, Edgar
    Arancibia, Veronica
    Rojas, Carlos
    Segura, Rodrigo
    TALANTA, 2012, 99 : 119 - 124
  • [33] DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF SODIUM CROMOGLYCATE AT A HANGING MERCURY DROP ELECTRODE
    MOREIRA, JC
    FOSTER, SE
    RODRIGUES, JA
    FOGG, AG
    ANALYST, 1992, 117 (06) : 989 - 991
  • [34] Differential Pulse Anodic Stripping Voltammetric Determination of Cadmium(II) at a Glassy Carbon Electrode Modified with a Nano-TiO2/Chitosan Composite Film
    Xie, Zhimin
    Fei, Junjie
    Huang, Meihua
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2008, 61 (12) : 1000 - 1005
  • [35] Adsorptive stripping voltammetric determination of venlafaxine in urine with a mercury film microelectrode
    Morais, S
    Ryckaert, CPMCA
    Delerue-Matos, C
    ANALYTICAL LETTERS, 2003, 36 (11) : 2515 - 2526
  • [36] DIRECT DIFFERENTIAL PULSE POLAROGRAPHIC AND ADSORPTIVE STRIPPING VOLTAMMETRIC ASSAY OF KETOTIFEN IN TABLETS
    BERSIER, PM
    SZCZEPANIAK, W
    REN, M
    ARCHIV DER PHARMAZIE, 1992, 325 (05) : 253 - 259
  • [37] Differential pulse, square wave and adsorptive stripping voltammetric quantification of tianeptine in tablets
    Gazy, AA
    Mahgoub, H
    Khamis, EF
    Youssef, RM
    El-Sayed, MA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1157 - 1163
  • [38] Determination of Trace Procaine Hydrochloride by Differential Pulse Adsorptive Stripping Voltammetry with a Nafion Modified Glassy Carbon Electrode
    Nianbing Li
    Jianping Duan
    Guonan Chen
    Analytical Sciences, 2003, 19 : 1587 - 1592
  • [39] Determination of trace procaine hydrochloride by differential pulse adsorptive stripping voltammetry with a nafion modified glassy carbon electrode
    Li, NB
    Duan, JP
    Chen, GN
    ANALYTICAL SCIENCES, 2003, 19 (12) : 1587 - 1592
  • [40] Differential Pulse Adsorptive Anodic Stripping Voltammetric Determination of Pipemidic Acid in Tablets at a Carbon Fiber Microdisk Electrode
    He, Y.-N.
    Chen, H.-Y.
    Electroanalysis, 9 (18):