Adsorptive stripping differential pulse voltammetric determination of metoprolol at Nafion-CNT-nano-composite film sensor

被引:37
|
作者
Desai, Purvi B. [1 ]
Srivastava, Ashwini K. [1 ]
机构
[1] Univ Mumbai, Dept Chem, Bombay 400098, Maharashtra, India
关键词
Metoprolol; Glassy carbon electrode; Nafion; Carbon nanotubes; Adsorptive differential pulse voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; WALLED CARBON NANOTUBES/NAFION; BETA-BLOCKERS; PASTE ELECTRODE; PHARMACEUTICAL-PREPARATIONS; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL-BEHAVIOR; GRAPHITE ELECTRODE; MASS-SPECTROMETRY; HUMAN URINE;
D O I
10.1016/j.snb.2012.10.073
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical method employing a Nafion-carbon nanotube-nano-composite film modified glassy carbon electrode (NAF-CNT-GCE) has been developed for the determination of metoprolol (MET). Cyclic voltammetry and adsorptive stripping differential pulse voltammetry were employed to study the electrochemical behavior of MET. Surface morphology of the electrodes was done using scanning electron microscopy. Studies reveal that the irreversible oxidation of MET was extremely facile on NAF-CNT-GCE. The optimized linear working range and detection limit (S/N = 3) are 7.02 x 10(-8) to 9.0 x 10(-6) M and 3.51 x 10(-8) M respectively. The analytical application of the modified GCE is demonstrated by determining MET in pharmaceutical formulations and biological fluids (serum and urine). The present sensor portrays certain advantages such as high sensitivity, simplicity, low detection limit and excellent reproducibility making the proposed method highly advantageous for MET determination. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:632 / 638
页数:7
相关论文
共 50 条
  • [1] Determination of amiloride at Nafion-CNT-nano-composite film sensor employing adsorptive stripping differential pulse voltammetry
    Desai, Purvi B.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 169 : 341 - 348
  • [2] Differential pulse adsorptive stripping voltammetric determination of benzocaine and butacaine with Nafion modified glassy carbon electrode
    Reddy, Tukiakula Madhusudana
    Balaji, Kodigutta
    Reddy, Srinivasulu Jayarama Reddy
    CROATICA CHEMICA ACTA, 2006, 79 (02) : 253 - 259
  • [3] Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode
    Sanghavi, Bankim J.
    Srivastava, Ashwini K.
    ELECTROCHIMICA ACTA, 2011, 56 (11) : 4188 - 4196
  • [4] Differential-pulse adsorptive stripping voltammetric determination of the antibacterial lomefloxacin
    Vílchez, JL
    Araujo, L
    Prieto, A
    Navalón, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (01) : 23 - 29
  • [5] Differential pulse adsorptive stripping voltammetric determination of zafirlukast in pharmaceutical formulations
    Süslü, I
    Altinöz, S
    ANALYTICAL LETTERS, 2005, 38 (10) : 1625 - 1639
  • [6] Differential pulse adsorptive stripping voltammetric determination of dinoseb and dinoterb at a modified electrode
    Sreedhar, M
    Reddy, LM
    Sirisha, KR
    Reddy, SRJ
    ANALYTICAL SCIENCES, 2003, 19 (04) : 511 - 516
  • [7] Differential pulse adsorptive stripping voltammetric determination of simeton in its formulations and vegetables
    N. Y. Sreedhar
    M. Sankara Nayak
    K. N. Shashi Kumar
    K. Srinivasa Prasad
    P. Reddy Prasad
    Environmental Monitoring and Assessment, 2010, 170 : 59 - 63
  • [8] Differential pulse adsorptive stripping voltammetric determination of simeton in its formulations and vegetables
    Sreedhar, N. Y.
    Nayak, M. Sankara
    Kumar, K. N. Shashi
    Prasad, K. Srinivasa
    Prasad, P. Reddy
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2010, 170 (1-4) : 59 - 63
  • [9] Differential Pulse Adsorptive Stripping Voltammetric Determination of Dinoseb and Dinoterb at a Modified Electrode
    Mallipattu Sreedhar
    Tukiakula Madhusudana Reddy
    Kami Reddy Sirisha
    Srinivasulu Reddy Jayarama Reddy
    Analytical Sciences, 2003, 19 : 511 - 516
  • [10] Differential pulse adsorptive stripping voltammetric determination of nanomolar levels of methotrexate utilizing bismuth film modified electrodes
    Asbahr, Deborah
    Figueiredo-Filho, Luiz Carlos S.
    Vicentini, Fernando Campanha
    Oliveira, Geiser Gabriel
    Fatibello-Filho, Orlando
    Banks, Craig E.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 334 - 339