Shear stress gradient over endothelial cells in a curved microchannel system

被引:15
|
作者
Frame, MDS
Chapman, GB
Makino, Y
Sarelius, IH
机构
[1] Univ Rochester, Sch Med & Dent, Dept Anesthesiol, Rochester, NY 14642 USA
[2] Univ Rochester, Sch Med & Dent, Dept Biophys, Rochester, NY 14642 USA
[3] Univ Rochester, Sch Med & Dent, Dept Physiol & Pharmacol, Rochester, NY 14642 USA
关键词
blood flow; computational fluid dynamics; shear gradient;
D O I
10.1016/S0006-355X(99)80009-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Our purpose was to test a scale model of the microcirculation by measuring the shear forces to which endothelial cells were exposed, and comparing this to computer simulations. In vitro experiments were performed to measure the 2-dimensional projected velocity profile along endothelial cell lined microchannels (D-shaped, 10-30 mu m radius, n = 15), or in microchannels without endothelial cells (n = 18). Microchannels were perfused with fluorescently labeled microspheres (0.5 mu m dia., <1%) suspended in cell culture media. The velocity of individual microspheres was obtained off-line (videorecording), using an interactive software program; velocity was determined as the distance traveled in one video field (1/60 s). Mass balance was verified in the microchannels by comparing the microsphere velocities to the perfusion pump rate. In confluent endothelial cell lined microchannels, a velocity profile was obtained as microspheres passed an endothelial cell nucleus (identified by fluorescent dye), and again, for a paired region 100 mu m away without nuclei (cytoplasm region). The velocity profile was significantly shifted and sharpened by the endothelial cell nucleus, as anticipated. Over the nucleus, data are consistent with a normal sized nucleus extending into the lumen, further confirming that this scale model can be used to determine the wall shear stress to which endothelial cells are exposed. Using the experimental bulk phase fluid parameters as boundary conditions, we used computational fluid dynamics (CFD) to predict the expected wall shear stress gradient along an endothelial cell lined D-shaped tube. The wall shear stress gradient over the nucleus was 2-fold greater in the radial versus axial directions, and was sensitive to lateral versus midline positioned nuclei.
引用
收藏
页码:245 / 261
页数:17
相关论文
共 50 条
  • [31] Shear stress prevents apoptosis of human endothelial cells
    Dimmeler, S
    Haendeler, J
    Neuls, M
    Zeiher, AM
    CIRCULATION, 1996, 94 (08) : 2757 - 2757
  • [32] Mobilizing endothelial progenitor cells by fluid shear stress
    Zhu, Chuhong
    Ying, Dajun
    Mi, Jianhong
    Li, Li
    Zen, Wen
    Hou, Chunli
    Song, Lin
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2008, 28 (06) : E146 - E146
  • [33] Secretome of Human Endothelial Cells under Shear Stress
    Burghoff, Sandra
    Schrader, Juergen
    JOURNAL OF PROTEOME RESEARCH, 2011, 10 (03) : 1160 - 1169
  • [34] Heterogeneous response of microvascular endothelial cells to shear stress
    Hong, D.
    Jaron, D.
    Buerk, D. G.
    Barbee, K. A.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 290 (06): : H2498 - H2508
  • [35] Mechanisms of shear stress transmission and transduction in endothelial cells
    Barakat, AI
    Davies, PF
    CHEST, 1998, 114 (01) : 58S - 63S
  • [36] High endothelial shear stress and stress gradient at plaque erosion persist up to 12 months
    Kim, Hyung Oh
    Jiang, Bo
    Poon, Eric K. W.
    Thondapu, Vikas
    Kim, Chong-Jin
    Kurihara, Osamu
    Araki, Makoto
    Nakajima, Akihiro
    Mamon, Chris
    Dijkstra, Jouke
    Lee, Hang
    Ooi, Andrew
    Barlis, Peter
    Jang, Ik-Kyung
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 357 : 1 - 7
  • [37] Effect of the endothelial surface layer on transmission of fluid shear stress to endothelial cells
    Secomb, TW
    Hsu, R
    Pries, AR
    BIORHEOLOGY, 2001, 38 (2-3) : 143 - 150
  • [38] The endothelial vessel wall shear stress ("shear stress")
    Chiriac, Liviu
    Cristian, Gabriel
    Nita, Daniel
    Carstea, Adela
    Murgu, Vasile
    Mocanu, Iancu
    Droc, Ionel
    Gheorghe, Lucian
    Tintoiu, Ion
    Greere, Vasile
    ROMANIAN JOURNAL OF MILITARY MEDICINE, 2011, 114 (04) : 3 - 12
  • [39] A microfluidic system for precisely reproducing physiological blood pressure and wall shear stress to endothelial cells
    Na, Jing-Tong
    Hu, Si-Yu
    Xue, Chun-Dong
    Wang, Yan-Xia
    Chen, Ke-Jie
    Li, Yong-Jiang
    Wang, Yu
    Qin, Kai-Rong
    ANALYST, 2021, 146 (19) : 5913 - 5922
  • [40] Proteomic analysis of shear stress protection mechanisms in endothelial cells
    Antczak, JK
    Greene, AS
    FASEB JOURNAL, 2006, 20 (05): : A1298 - A1298