Assessment of agreement between molar landmarks: Repeatability, reproducibility, and comparability

被引:2
|
作者
Varlik, Selin Kale [1 ]
Uzuner, Deniz [1 ]
Tortop, Tuba [1 ]
机构
[1] Gazi Univ, Dept Orthodont, Fac Dent, TR-06510 Ankara, Turkey
关键词
PENDULUM APPLIANCE; CEPHALOMETRIC LANDMARKS; JONES JIG; DISTALIZATION; IDENTIFICATION; ANCHORAGE; RELIABILITY; RADIOGRAPHS; MOVEMENT; SKELETAL;
D O I
10.1016/j.ajodo.2016.02.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aims of this research were to test the repeatability and reproducibility of measurements obtained by different molar landmarks and to determine whether the treatment changes measured by them are comparable. Materials: Pretreatment (T0) and postdistalization (T1) lateral cephalograms of 40 patients with a Class II molar relationship were used. Using the mesial cusp tip, distal crown contour, and centroid, 6 linear and 3 angular measurements were evaluated. The intraexaminer and interexaminer reliabilities were assessed with the Bland-Altman method. The T0 to T1 differences were compared by analysis of variance, followed by multiple comparisons with the Bonferroni adjustment. Results: The greatest intraexaminer agreement intervals were correlated with centroid for tipping and vertical movement, and with distal crown contour for anteroposterior movement at T0 and T1. The narrowest interexaminer agreement intervals were observed with mesial cusp tip for all measurements and comparisons at both time points, except for the anteroposterior measurements at T1. Statistical significance was observed between the measurements made with mesial cusp tip and distal crown contour for tipping and with mesial cusp tip and centroid for distalization. For vertical movement, the treatment changes were statistically significantly greater with distal crown contour. Conclusions: Mesial cusp tip was the most repeatable and reproducible landmark. Clinically unimportant differences were found in some comparisons of treatment changes obtained by different landmarks.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 50 条
  • [31] Repeatability, reproducibility, agreement characteristics of 2 SD-OCT devices for anterior chamber angle
    Akil, Handan
    Dastiridou, Anna
    Marion, Kenneth
    Francis, Brian
    Chopra, Vikas
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2017, 52 (02): : 166 - 170
  • [32] Feasibility, Reproducibility, and Agreement between Different Speckle Tracking Echocardiographic Techniques for the Assessment of Longitudinal Deformation
    Buccheri, Sergio
    Monte, Ines
    Mangiafico, Sarah
    Bottari, Vera
    Leggio, Stefano
    Tamburino, Corrado
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [33] Assessment of the repeatability and reproducibility of hydrogen/deuterium exchange mass spectrometry measurements
    Burkitt, William
    O'Connor, Gavin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (23) : 3893 - 3901
  • [34] A Phantom-Based Assessment of Repeatability and Reproducibility of Transvaginal Quantitative Ultrasound
    Chen, Shi
    McFarlin, Barbara L.
    Meagher, Barbara T.
    Peters, Tara A.
    Simpson, Douglas G.
    O'Brien, William D., Jr.
    Han, Aiguo
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (09) : 1413 - 1421
  • [35] The Creation and Assessment of a Gage Repeatability and Reproducibility Study Exercise in a Metrology Class
    Kozak, Michael J.
    2011 ASEE ANNUAL CONFERENCE & EXPOSITION, 2011,
  • [36] Intrasession repeatability and agreement of the anterior corneal assessment provided by a multidiagnostic device
    Barrio, Ana Rosa
    Antona, Beatriz
    Morago-Villanueva, Sofia
    Martinez-Arribas, Victor
    Gonzalez-Perez, Mariano
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2025, 108 (02) : 135 - 141
  • [37] Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology
    McAlinden, Colm
    Khadka, Jyoti
    Pesudovs, Konrad
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (04) : 330 - 338
  • [38] Precision Analysis of Posterior Corneal Topography Measured by Visante Omni: Repeatability, Reproducibility, and Agreement With Orbscan II
    Srivannaboon, Sabong
    Chotikavanich, Suksri
    Chirapapaisan, Chareenun
    Kasemson, Sirilux
    Po-ngam, Wasin
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (02) : 133 - U123
  • [39] Evaluation of a New Fully Automatic OLCR Biometer: Repeatability, Reproducibility, and Agreement with an SS-OCT Biometer
    Lei, Chak Seng
    Yang, Xinning
    Ning, Rui
    Xiahou, Jinxuan
    Jiang, Xinyu
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Li, Kexin
    Huang, Jinhai
    OPHTHALMOLOGY AND THERAPY, 2025, : 1097 - 1109
  • [40] Anterior chamber depth measurements using Scheimpflug imaging and optical coherence tomography: Repeatability, reproducibility, and agreement
    Wang, Qinmei
    Ding, Xixia
    Savini, Giacomo
    Chen, Hao
    Feng, Yifan
    Pan, Chao
    Hua, Yanjun
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01): : 178 - 185