Assessment of agreement between molar landmarks: Repeatability, reproducibility, and comparability

被引:2
|
作者
Varlik, Selin Kale [1 ]
Uzuner, Deniz [1 ]
Tortop, Tuba [1 ]
机构
[1] Gazi Univ, Dept Orthodont, Fac Dent, TR-06510 Ankara, Turkey
关键词
PENDULUM APPLIANCE; CEPHALOMETRIC LANDMARKS; JONES JIG; DISTALIZATION; IDENTIFICATION; ANCHORAGE; RELIABILITY; RADIOGRAPHS; MOVEMENT; SKELETAL;
D O I
10.1016/j.ajodo.2016.02.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aims of this research were to test the repeatability and reproducibility of measurements obtained by different molar landmarks and to determine whether the treatment changes measured by them are comparable. Materials: Pretreatment (T0) and postdistalization (T1) lateral cephalograms of 40 patients with a Class II molar relationship were used. Using the mesial cusp tip, distal crown contour, and centroid, 6 linear and 3 angular measurements were evaluated. The intraexaminer and interexaminer reliabilities were assessed with the Bland-Altman method. The T0 to T1 differences were compared by analysis of variance, followed by multiple comparisons with the Bonferroni adjustment. Results: The greatest intraexaminer agreement intervals were correlated with centroid for tipping and vertical movement, and with distal crown contour for anteroposterior movement at T0 and T1. The narrowest interexaminer agreement intervals were observed with mesial cusp tip for all measurements and comparisons at both time points, except for the anteroposterior measurements at T1. Statistical significance was observed between the measurements made with mesial cusp tip and distal crown contour for tipping and with mesial cusp tip and centroid for distalization. For vertical movement, the treatment changes were statistically significantly greater with distal crown contour. Conclusions: Mesial cusp tip was the most repeatable and reproducible landmark. Clinically unimportant differences were found in some comparisons of treatment changes obtained by different landmarks.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 50 条
  • [1] Assessment of agreement between anesthesiologists' location of anatomical landmarks
    Navarro, R.
    Guasch, E.
    Parodi, E.
    Gilsanz, F.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (03): : 144 - 150
  • [2] Assessing Measurement System Agreement in the Presence of Reproducibility and Repeatability
    Ahmadi Nadi, Adel
    Steiner, Stefan H.
    Stevens, Nathaniel T.
    TECHNOMETRICS, 2024, 66 (03) : 319 - 330
  • [3] Reproducibility and agreement between three positions for handgrip assessment
    Vargas-Pinilla, Olga-Cecilia
    Rodriguez-Grande, Eliana-Isabel
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Reproducibility and agreement between three positions for handgrip assessment
    Olga-Cecilia Vargas-Pinilla
    Eliana-Isabel Rodríguez-Grande
    Scientific Reports, 11
  • [5] Comparability and repeatability of different methods of corneal astigmatism assessment
    Ferreira, Tiago B.
    Ribeiro, Filomena J.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 29 - 34
  • [6] Repeatability and reproducibility of landmarks-a three-dimensional computed tomography study
    Titiz, Irem
    Laubinger, Michala
    Keller, Thomas
    Hertrich, Klaus
    Hirschfelder, Ursula
    EUROPEAN JOURNAL OF ORTHODONTICS, 2012, 34 (03) : 276 - 286
  • [7] An Assessment of Gauge Repeatability and Reproducibility with Multiple Characteristics
    Wang, Fu-Kwun
    JOURNAL OF TESTING AND EVALUATION, 2013, 41 (04) : 651 - 658
  • [8] Repeatability, Reproducibility, and Agreement Between Three Different Scheimpflug Systems in Measuring Corneal and Anterior Segment Biometry
    Hernandez-Camarena, Julio C.
    Chirinos-Saldana, Patricia
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    de la Mota, Angie
    Jimenez-Corona, Aida
    Graue-Hernandez, Enrique O.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (09) : 616 - U44
  • [9] Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits
    Christian J. F. Bertens
    Ralph J. S. van Mechelen
    Tos T. J. M. Berendschot
    Marlies Gijs
    Jarno E. J. Wolters
    Theo G. M. F. Gorgels
    Rudy M. M. A. Nuijts
    Henny J. M. Beckers
    Scientific Reports, 11
  • [10] Repeatability, reproducibility, and agreement of three tonometers for measuring intraocular pressure in rabbits
    Bertens, Christian J. F.
    van Mechelen, Ralph J. S.
    Berendschot, Tos T. J. M.
    Gijs, Marlies
    Wolters, Jarno E. J.
    Gorgels, Theo G. M. F.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    SCIENTIFIC REPORTS, 2021, 11 (01)