Evaluation of microvascularization in focal salivary gland lesions by contrast-enhanced ultrasonography (CEUS) and Color Doppler sonography

被引:41
|
作者
Wei, Xi [1 ]
Li, Ying [2 ]
Zhang, Sheng [1 ]
Li, Xubin [3 ]
Wang, Hailing [1 ]
Yong, Xu [1 ]
Wang, Xiaoqing [1 ]
Li, Xing [1 ]
Gao, Ming [4 ]
机构
[1] Tianjin Med Univ Canc Inst & Hosp, Dept Diagnost & Therapeut Ultrasonog, Key Lab Canc Prevent & Therapy, Tianjin 300060, Peoples R China
[2] Tianjin Med Univ Canc Inst & Hosp, Dept Breast Canc 3, Key Lab Canc Prevent & Therapy, Tianjin 300060, Peoples R China
[3] Tianjin Med Univ Canc Inst & Hosp, Dept Radiol, Key Lab Canc Prevent & Therapy, Tianjin 300060, Peoples R China
[4] Tianjin Med Univ Canc Inst & Hosp, Dept Thyroid & Cerv Tumor, Key Lab Canc Prevent & Therapy, Tianjin 300060, Peoples R China
关键词
Salivary gland lesions; microvascularity; CEUS; Color Doppler; combined score grade; HIGH-RESOLUTION ULTRASOUND; PAROTID TUMORS; DISEASES; MICROCIRCULATION; ELASTOGRAPHY; TIME;
D O I
10.3233/CH-131732
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To evaluate the dynamic microvascularization of focal salivary gland lesions by contrast-enhanced ultrasound (CEUS) and Color Doppler sonography. MATERIALS AND METHODS: One hundred and sixty-eight patients with 183 major salivary gland lesions (mean age, 56 years; age range, 12-83 years) underwent gray-scale ultrasonography (US), Color Doppler (CD) and CEUS. The CD and CEUS patterns were classified into three types (scores 0-3). Combined score grades were calculated based on the CD and CEUS pattern scores. The time-intensity curve (TIC) parameters of CEUS were then analyzed. Sensitivity, specificity, negative predictive value and positive predictive value of combined score grades were also calculated. RESULTS: Among all the lesions, there were 161 in parotid gland, 22 in submandibular gland and 157 lesions were benign and 26 were malignant. For score grades (combined CEUS patterns with CD types), scores 1-2 were graded as benign; scores 3-4 were graded as indetermination-suspicious benign or malignant and scores 5-6 were graded as malignant. score 5-6 and score 1-2 indicated 24 (92.3%) and 135 (85.9%) malignant and benign lesions confirmed pathologically, respectively. The sensitivity and negative predicted value of combined score grades for malignant lesions were 92.3% and 98.5%, respectively. In addition, TIC analysis indicates that PI and AUC in malignant lesions were higher than those in benign lesions (p = 0.04 and 0.02, respectively). CONCLUSION: The combined score grade could be a useful method to assess the macro-and micro-vascularization and to differentiated diagnose benign and malignant lesions in major salivary glands.
引用
收藏
页码:259 / 271
页数:13
相关论文
共 50 条
  • [41] CRYOTHERAPY IN RENAL CELL CANCER: EVALUATION OF TREATMENT BY CONTRAST-ENHANCED ULTRASONOGRAPHY (CEUS)
    Siracusano, Salvatore
    Bertolotto, Michele
    Cacciato, Francesca
    Cazzagon, Matilde
    Ciciliato, Stefano
    Toffoli, Laura
    Visalli, Francesco
    Silvestri, Tommaso
    Stacul, Fulvio
    ANTICANCER RESEARCH, 2015, 35 (06) : 3646 - 3646
  • [42] Phase inversion harmonic imaging versus contrast-enhanced power Doppler sonography for the characterization of focal liver lesions
    Deike Strobel
    Sabine Raeker
    Peter Martus
    Eckhart Hahn
    Dirk Becker
    International Journal of Colorectal Disease, 2003, 18 : 63 - 72
  • [43] Phase inversion harmonic imaging versus contrast-enhanced power Doppler sonography for the characterization of focal liver lesions
    Strobel, D
    Raeker, S
    Martus, P
    Hahn, EG
    Becker, D
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2003, 18 (01) : 63 - 72
  • [44] Contrast-enhanced ultrasonography in the evaluation of incidental focal liver lesions: A cost-effectiveness analysis
    Miriama Smajerova
    Hana Petrasova
    Jirina Little
    Petra Ovesna
    Tomas Andrasina
    Vlastimil Valek
    Eva Nemcova
    Barbora Miklosova
    World Journal of Gastroenterology, 2016, 22 (38) : 8605 - 8614
  • [45] Comparison of Contrast-Enhanced Ultrasonography with Virtual Touch Tissue Quantification in the Evaluation of Focal Liver Lesions
    Wu, Jing-ping
    Shu, Rui
    Zhao, Yu-zhen
    Ma, Guo-lin
    Xue, Wei
    He, Qi-jia
    Hao, Mei-na
    Liu, Yawu
    JOURNAL OF CLINICAL ULTRASOUND, 2016, 44 (06) : 347 - 353
  • [46] Contrast-enhanced ultrasonography in the evaluation of incidental focal liver lesions: A cost-effectiveness analysis
    Smajerova, Miriama
    Petrasova, Hana
    Little, Jirina
    Ovesna, Petra
    Andrasina, Tomas
    Valek, Vlastimil
    Nemcova, Eva
    Miklosova, Barbora
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (38) : 8605 - 8614
  • [47] Contrast-enhanced Ultrasound (CEUS) for the Detection and Assessment of Treatment Efficacy in Focal Liver Lesions
    Gheorghe, Liana
    Carabelea, A.
    Vadan, Roxana
    Becheanu, Gabriel
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2009, 18 (04) : 473 - +
  • [48] Contrast-Enhanced Colour Doppler Ultrasound Scan (CEUS) in the Evaluation of Hemophilic Arthropathy
    Tagariello, G.
    Radossi, P.
    Cesari, S. .
    Sartori, R.
    Maschio, N.
    Tassinari, C.
    Risato, R.
    Scarpa, E.
    HAEMOPHILIA, 2012, 18 : 128 - 129
  • [49] Contrast-enhanced color Doppler sonography improves the diagnosis of hepatocellular carcinoma.
    Strobel, D
    Krodel, U
    Becker, D
    Bartus, P
    Hahn, EG
    HEPATOLOGY, 1998, 28 (04) : 755A - 755A
  • [50] The role of contrast-enhanced Sonography of focal liver lesions before percutaneous biopsy
    Wu, Wei
    Chen, Min-Hua
    Yin, Shan-Shan
    Yan, Kun
    Fan, Zhi-Hui
    Yang, Wei
    Dai, Ying
    Huo, Ling
    Li, Ji-You
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 752 - 761