Imaging of the choroid with the Scanning Slit Laser Ophthalmoscope (SSLO)

被引:0
|
作者
Heacock, G [1 ]
Zwick, H [1 ]
Marshall, J [1 ]
Stuck, BE [1 ]
Cook, H [1 ]
机构
[1] Univ London, St Thomas Hosp, UMDS, London, England
关键词
scanning laser ophthalmoscopy; portable ophthalmoscopy; angiography; confocal; spectral ophthalmoscopy;
D O I
10.1117/12.350610
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Imaging of chorodial features is possible through. an undilated pupil, and without the use of dye by employing a new device which scans a laser line over the patients fundus to form real, time video images. Further adjustments allow the device to produce images having fields of view from 60 to 15 degrees in width. Additionally, diode laser sources provide illumination wavelengths of 532, 635, 670, 690, and 820 nn. The combined functions of line scanning, adjustable focus depth in the z plane, and switchable illumination wavelength produce greyscale video images which clearly show detailed features of the patients choroid. In addition, the optic nerve head geometry is shown with very high resolution.
引用
收藏
页码:456 / 464
页数:9
相关论文
共 50 条
  • [1] CONFOCAL SCANNING LASER OPHTHALMOSCOPE WITH A SLIT APERTURE
    KOBAYASHI, K
    NAKANO, H
    MATSUI, H
    AKIYAMA, K
    ASAKURA, T
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (04) : 287 - 292
  • [2] Digital analysis of scanning slit laser ophthalmoscope images.
    Mensah, E
    Usher, D
    Heacock, GL
    Boyce, JF
    Marshall, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S786 - S786
  • [3] IMAGING TECHNIQUES AND APPLICATIONS OF THE SCANNING LASER OPHTHALMOSCOPE
    KOBAYASHI, K
    ASAKURA, T
    OPTICAL ENGINEERING, 1995, 34 (03) : 717 - 726
  • [4] Colour imaging using a scanning laser ophthalmoscope
    Fitzke, FW
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (04) : 337 - 338
  • [5] Occult CNV imaging with scanning laser ophthalmoscope
    Carlos Argento
    Omar Lopez Lopez
    Mauricio Martinez Cartier
    International Ophthalmology, 2001, 23 (4-6) : 409 - 412
  • [6] The automated detection of exudates in scanning laser slit ophthalmoscope images.
    Mensah, E
    Usher, D
    Watters, W
    Heacock, G
    Boyce, JF
    Marshall, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S809 - S809
  • [7] Imaging of Pseudophakic Eyes Using a Widefield Slit-Scanning Ophthalmoscope
    Everett, Matthew J.
    Luu, Jennifer
    Brock, T. Keith
    Leahy, Conor
    Schmidt, Jeff
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [8] Indocyanine green videoangiography of malignant melanomas of the choroid using the scanning laser ophthalmoscope
    Schneider, U
    Gelisken, F
    Inhoffen, W
    Kreissig, I
    GERMAN JOURNAL OF OPHTHALMOLOGY, 1996, 5 (01) : 6 - 11
  • [9] Wavelength-specific imaging of the posterior pole with a low-cost, portable scanning slit laser ophthalmoscope
    Cook, HL
    Heacock, GL
    Watters, WH
    Marshall, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S756 - S756
  • [10] Simultaneous three wavelength imaging with a scanning laser ophthalmoscope
    Reinholz, F
    Ashman, RA
    Eikelboom, RH
    CYTOMETRY, 1999, 37 (03): : 165 - 170