Biomechanical Evaluation of Anterior Thoracic Salvage Screws in the Osteoporotic Thoracic Spine

被引:2
|
作者
Behrend, Caleb [1 ]
George, Stephen [2 ]
Molinari, Robert [2 ]
机构
[1] Virginia Tech Carilion SOM Res Inst, Div Orthoped Surg, Roanoke, VA USA
[2] Univ Rochester, Strong Mem Hosp, Dept Orthopaed & Rehabil, Rochester, NY 14642 USA
来源
关键词
biomechanics; anterior thoracic; screw; pullout; revision; osteoporosis; CALCIUM-PHOSPHATE CEMENT; CERVICAL PLATE FIXATION; CANCELLOUS BONE SCREWS; PULLOUT STRENGTH; PEDICLE SCREWS; RESCUE SCREWS; PILOT HOLE; AUGMENTATION; REVISION; TORQUE;
D O I
10.1097/BSD.0b013e318286f657
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design:Controlled, cadaveric implantation trial.Objective:Evaluation of revision thoracic screw fixation: with revision from unicortical screws to bicortical screws, to larger diameter screws, and the addition of bone cement.Summary of Background Data:Limited data is available regarding the effect of salvage screws on fixation quality in the anterior thoracic spine. Biomechanical studies in the cervical spine and the lumbar spine demonstrate dramatic decreases in fixation in salvage situations.Methods:Seventy-two cadaveric thoracic vertebrae from 6 specimens were DEXA scanned at T1-T12. A control screw and a second identical screw were placed in each segment. One screw was then removed and replaced with a revision screw. Varying screw diameter, the number of cortices, and the addition of 1.5 cm(3) of bone cement was evaluated in a pairwise fashion. Comparisons were made using descriptive statistical analysis and a general linear statistical model.Results:Bone mineral density had a significant effect on the pullout force. Pullout force did not vary significantly with control screw diameter. Revision of a smaller diameter bicortical to a larger diameter bicortical screw resulted in a decrease in pullout strength for 4-5 mm screws by 40.1% (P=0.02) and 5-7 mm screws by 63.7% (P=0.05). When a 4 mm bicortical screw is revised to a 5 mm unicortical screw, the pullout force decreases by 67.7% (P<0.001). There was a nonsignificant increase (44%) in pullout with revision of a unicortical 4 mm screw to a bicortical 4 mm screw. If a bicortical screw is revised to a unicortical screw with 1.5 cm(3) of cement, the pullout strength is increased by 240% (P<0.001).Conclusions:When the use of salvage screws is required, the surgeon should anticipate a significant decrease in the holding force compared with the original screw regardless of screw size unless a unicortical screw is revised to a bicortical screw or cement is added to the construct.
引用
收藏
页码:E235 / E239
页数:5
相关论文
共 50 条
  • [21] The effect of hypokyphosis on the biomechanical behavior of the adolescent thoracic spine
    Aroeira, Rozilene Maria C.
    Pertence, Antonio Eustaquio M.
    Kemmoku, Daniel Takanori
    Greco, Marcelo
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2018, 40 (03)
  • [22] Biomechanical properties of human thoracic spine disc segments
    Stemper, B. D.
    Board, D.
    Yoganandan, N.
    Wolfla, C. E.
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2010, 1 (01): : 18 - 22
  • [23] VIDEO-ASSISTED THORACIC-SURGERY FOR THE ANTERIOR APPROACH TO THE THORACIC SPINE
    MACK, MJ
    REGAN, JJ
    MCAFEE, PC
    PICETTI, G
    BENYISHAY, A
    ACUFF, TE
    ANNALS OF THORACIC SURGERY, 1995, 59 (05): : 1100 - 1106
  • [24] The effect of hypokyphosis on the biomechanical behavior of the adolescent thoracic spine
    Rozilene Maria C. Aroeira
    Antônio Eustáquio M. Pertence
    Daniel Takanori Kemmoku
    Marcelo Greco
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2018, 40
  • [25] Are breech rates for pedicle screws higher in the upper thoracic spine?
    Privitera D.M.
    Matsumoto H.
    Gomez J.A.
    Roye Jr. D.P.
    Hyman J.E.
    Vitale M.G.
    Spine Deformity, 2013, 1 (3) : 189 - 195
  • [26] A BIOMECHANICAL STUDY OF THE LIGAMENTOUS STABILITY OF THE THORACIC SPINE IN MAN
    PANJABI, MM
    HAUSFELD, JN
    WHITE, AA
    ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (03): : 315 - 326
  • [27] Biomechanical comparison of plates and rods in the unstable thoracic spine
    Rapoff, AJ
    O'Brien, TJ
    Zdeblick, TA
    JOURNAL OF SPINAL DISORDERS, 1999, 12 (02): : 115 - 119
  • [29] Posterior instrumentation for osteoporotic fractures in the thoracic or lumbar spine: Cement-augmented pedicle screws vs hybrid constructs
    Chou, Po-Hsin
    Lin, Hsi-Hsien
    Yao, Yu-Cheng
    Wang, Shih-Tien
    Chang, Ming-Chau
    Liu, Chien-Lin
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2023, 86 (04) : 431 - 439
  • [30] Classification of symptomatic osteoporotic compression fractures of the thoracic and lumbar spine
    Wu, CT
    Lee, SC
    Lee, ST
    Chen, JF
    JOURNAL OF CLINICAL NEUROSCIENCE, 2006, 13 (01) : 31 - 38