Position estimation using neural networks in semi-monolithic PET detectors

被引:14
|
作者
Freire, M. [1 ]
Barrio, J. [1 ]
Cucarella, N. [1 ]
Valladares, C. [1 ]
Gonzalez-Montoro, A. [1 ]
de Alfonso, C. [1 ]
Benlloch, J. M. [1 ]
Gonzalez, A. J. [1 ]
机构
[1] Univ Politecn Valencia, Ctr Mixto CSIC, Inst Instrumentac Imagen Mol I3M, Camino Vera s-n, E-46022 Valencia, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 24期
关键词
semi-monolithic detector; neural network; PET; total body PET; position estimation; machine learning; FIELD-OF-VIEW; DOI CAPABILITY; PERFORMANCE; ALGORITHM; CRYSTALS; DESIGN;
D O I
10.1088/1361-6560/aca389
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The goal of this work is to experimentally compare the 3D spatial and energy resolution of a semi-monolithic detector suitable for total-body positron emission tomography (TB-PET) scanners using different surface crystal treatments and silicon photomultiplier (SiPM) models. Approach. An array of 1 x 8 lutetium yttrium oxyorthosilicate (LYSO) slabs of 25.8 x 3.1 x 20 mm(3) separated with Enhanced Specular Reflector (ESR) was coupled to an array of 8 x 8 SiPMs. Three different treatments for the crystal were evaluated: ESR + RR + B, with lateral faces black (B) painted and a retroreflector (RR) layer added to the top face; ESR + RR, with lateral faces covered with ESR and a RR layer on the top face and; All ESR, with lateral and top sides with ESR. Additionally, two SiPM array models from Hamamatsu Photonics belonging to the series S13361-3050AE-08 (S13) and S14161-3050AS-08 (S14) have been compared. Coincidence data was experimentally acquired using a Na-22 point source, a pinhole collimator, a reference detector and moving the detector under study in 1 mm steps in the x- and DOI- directions. The spatial performance was evaluated by implementing a neural network (NN) technique for the impact position estimation in the x- (monolithic) and DOI directions. Results. Energy resolution values of 16 +/- 1%, 11 +/- 1%, 16 +/- 1%, 15 +/- 1%, and 13 +/- 1% were obtained for the S1 3-ESR + B + RR, S1 3-All ESR, S14-ESR + B + RR, S14-ESR + RR, and S14-All ESR, respectively. Regarding positioning accuracy, mean average error of 1.1 +/- 0.5, 1.3 +/- 0.5 and 1.3 +/- 0.5 were estimated for the x- direction and 1.7 +/- 0.8, 2.0 +/- 0.9 and 2.2 +/- 1.0 for the DOI- direction, for the ESR + B + RR, ESR + RR and All ESR cases, respectively, regardless of the SiPM model. Significance. Overall, the obtained results show that the proposed semi-monolithic detectors are good candidates for building TB-PET scanners.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Performance of long rectangular semi-monolithic scintillator PET detectors
    Zhang, Xianming
    Wang, Xiaohui
    Ren, Ning
    Hu, Bitao
    Ding, Baowei
    Kuang, Zhonghua
    Wu, San
    Sang, Ziru
    Hu, Zhanli
    Du, Junwei
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    MEDICAL PHYSICS, 2019, 46 (04) : 1608 - 1619
  • [2] Resolution estimation in different monolithic PET detectors using neural networks
    Belov, M. V.
    Kozlov, V. A.
    Tskhay, V. S.
    Zavertyaev, M. V.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 106
  • [3] Ensemble of neural networks for 3D position estimation in monolithic PET detectors
    Iborra, A.
    Gonzalez, A. J.
    Gonzalez-Montoro, A.
    Bousse, A.
    Visvikis, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (19):
  • [4] PET scanners constructed with a monolithic scintillator ring and semi-monolithic rings
    Xie, S.
    Zhang, X.
    Peng, H.
    Yang, J.
    Zhao, Z.
    Huang, Q.
    Xu, J.
    Peng, Q.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [5] Performance of a SiPM based semi-monolithic scintillator PET detector
    Zhang, Xianming
    Wang, Xiaohui
    Ren, Ning
    Kuang, Zhonghua
    Deng, Xinhan
    Fu, Xin
    Wu, San
    Sang, Ziru
    Hu, Zhanli
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19): : 7889 - 7904
  • [6] A thick semi-monolithic scintillator detector for clinical PET scanners
    Zhang, Chunhui
    Wang, Xiaohui
    Sun, Mingdao
    Kuang, Zhonghua
    Zhang, Xianming
    Ren, Ning
    Wu, San
    Sang, Ziru
    Sun, Tao
    Hu, Zhanli
    Yang, Yongfeng
    Liu, Zheng
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [7] Neural network-based position estimators for PET detectors using monolithic LSO blocks
    Bruyndonckx, P
    Léonard, S
    Tavernier, S
    Lemaître, C
    Devroede, O
    Wu, YB
    Krieguer, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2520 - 2525
  • [8] Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals
    Cucarella, Neus
    Barrio, John
    Lamprou, Efthymios
    Valladares, Celia
    Benlloch, Jose M.
    Gonzalez, Antonio J.
    MEDICAL PHYSICS, 2021, 48 (12) : 8010 - 8023
  • [9] A finely segmented semi-monolithic detector tailored for high-resolution PET
    Kuhl, Yannick
    Mueller, Florian
    Naunheim, Stephan
    Bovelett, Matthias
    Lambertus, Janko
    Schug, David
    Weissler, Bjoern
    Gegenmantel, Eike
    Gebhardt, Pierre
    Schulz, Volkmar
    MEDICAL PHYSICS, 2024, 51 (05) : 3421 - 3436
  • [10] Artificial neural networks for positioning of gamma interactions in monolithic PET detectors
    Decuyper, Milan
    Stockhoff, Mariele
    Vandenberghe, Stefaan
    Van Holen, Roel
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):