Long-Term Effect of Surface Light Scattering and Glistenings of Intraocular Lenses on Visual Function

被引:51
|
作者
Hayashi, Ken [1 ]
Hirata, Akira [2 ]
Yoshida, Motoaki
Yoshimura, Koichi
Hayashi, Hideyuki [3 ]
机构
[1] Hayashi Eye Hosp, Hakata Ku, Fukuoka 8120011, Japan
[2] Saga Univ, Dept Ophthalmol, Fac Med, Saga 840, Japan
[3] Fukuoka Univ, Dept Ophthalmol, Sch Med, Fukuoka 81401, Japan
关键词
POSTERIOR CAPSULE OPACIFICATION; IN-VITRO ANALYSIS; SINGLE-PIECE; ACRYSOF; SILICONE; ABERRATIONS; POLYMETHYLMETHACRYLATE; SHARP;
D O I
10.1016/j.ajo.2012.03.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. DESIGN: Case-control study. METHODS: Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. RESULTS: Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. CONCLUSIONS: At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations. (Am J Ophthalmol 2012;154:240-251. (c) 2012 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:240 / 251
页数:12
相关论文
共 50 条
  • [21] LONG-TERM STUDY OF CHILDREN WITH IMPLANTED INTRAOCULAR LENSES
    KORA, Y
    INATOMI, M
    FUKADO, Y
    MARUMORI, M
    YAGUCHI, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05): : 485 - 488
  • [22] Effects of intraocular lens glistenings on visual function: a prospective study and presentation of a new glistenings grading methodology
    Stanojcic, Nick
    O'Brart, David P. S.
    Maycock, Nick
    Hull, Chistopher C.
    BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01):
  • [23] Light Transmittance of Explanted Hydrophobic Acrylic Intraocular Lenses with Surface Light Scattering
    Werner, Liliana
    Morris, Caleb
    Stallings, Shannon
    Liu, Erica
    Floyd, Anne
    Ollerton, Andrew
    Leishman, Lisa
    Bodnar, Zachary
    Ong, Marcia
    Akinay, Ali
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [24] Change in light scattering caused by glistenings in hydrophobic acrylic intraocular lenses from 10 to 15 years after surgery
    Monestam, Eva
    Behndig, Anders
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (06): : 864 - 869
  • [25] Effect of Blue Light Filtering Intraocular Lenses on Visual Perception
    Popov, Ivajlo
    Jurenova, Denisa
    Valaskova, Jela
    Sanchez-Chicharro, Diego
    Stefanickova, Jana
    Waczulikova, Iveta
    Krasnik, Vladimir
    MEDICINA-LITHUANIA, 2021, 57 (06):
  • [26] In vitro examination of surface light scattering in hydrophobic acrylic intraocular lenses
    Minami, Keiichiro
    Maruyama, Yoko
    Honbo, Masato
    Matsunaga, Jiro
    Miyata, Kazunori
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 652 - 656
  • [27] Optical performance of hydrophobic acrylic intraocular lenses with surface light scattering
    Ogura, Yuichiro
    Ong, Marcia D.
    Akinay, Ali
    Carson, Daniel R.
    Pei, Ron
    Karakelle, Mutlu
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01): : 104 - 113
  • [28] A study of the long-term transparency of new Acrysof® intraocular lenses
    Kawai, Kenji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [29] Iris-sutured intraocular lenses and their long-term outcomes
    Lim, Jane S.
    Chiam, Nathalie P. Y.
    Wong, Melissa H. Y.
    Chee, Soon-Phaik
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 52 (08): : 893 - 896
  • [30] Long-term stability of the heparin surface on PMMA-intraocular lenses - results of an in vitro study
    Dick, B
    Greiner, K
    Magdowski, G
    Pfeiffer, N
    OPHTHALMOLOGE, 1997, 94 (12): : 920 - 924