Modelling plastic scintillator response to gamma rays using light transport incorporated FLUKA code

被引:12
|
作者
Kohan, M. Ranjbar [2 ]
Etaati, G. R. [3 ]
Ghal-Eh, N. [1 ]
Safari, M. J. [4 ]
Afarideh, H. [3 ]
Asadi, E. [5 ]
机构
[1] Damghan Univ, Sch Phys, Damghan, Iran
[2] Tafresh Univ, Dept Phys, Tafresh, Iran
[3] Amirkabir Univ Technol, Dept Nucl Engn & Phys, Tehran, Iran
[4] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
[5] Payam E Noor Univ, Dept Phys, Tehran, Iran
关键词
Scintillator; Monte Carlo; FLUKA; PHOTRACK; Response function; Detection resolution; PHOTON;
D O I
10.1016/j.apradiso.2012.01.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The response function of NE102 plastic scintillator to gamma rays has been simulated using a joint FLUKA+PHOTRACK Monte Carlo code. The multi-purpose particle transport code, FLUKA, has been responsible for gamma transport whilst the light transport code. PHOTRACK, has simulated the transport of scintillation photons through scintillator and lightguide. The simulation results of plastic scintillator with/without light guides of different surface coverings have been successfully verified with experiments. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:864 / 867
页数:4
相关论文
共 50 条
  • [1] Light-transport incorporated plastic scintillator response to prompt gamma-rays for use in range verification of proton therapy
    Shahsavari, A.
    Ghal-Eh, N.
    Najafabadi, R. Izadi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1049
  • [2] Studying the response of a plastic scintillator to gamma rays using the Geant4 Monte Carlo code
    Ghadiri, Rasoul
    Khorsandi, Jamshid
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 63 - 68
  • [3] Comparison of light transport-incorporated MCNPX and FLUKA codes in generating organic scintillators responses to neutrons and gamma rays
    Tajik, M.
    Ghal-Eh, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 791 : 65 - 68
  • [4] Response of plastic scintillator to gamma sources
    Tajudin, Suffian M.
    Namito, Y.
    Sanami, T.
    Hirayama, H.
    APPLIED RADIATION AND ISOTOPES, 2020, 159
  • [5] X- and gamma-rays attenuation properties of DNA nucleobases by using FLUKA simulation code
    M. S. Al-Buriahi
    Chahkrit Sriwunkum
    Imed Boukhris
    The European Physical Journal Plus, 136
  • [6] X- and gamma-rays attenuation properties of DNA nucleobases by using FLUKA simulation code
    Al-Buriahi, M. S.
    Sriwunkum, Chahkrit
    Boukhris, Imed
    EUROPEAN PHYSICAL JOURNAL PLUS, 2021, 136 (07):
  • [7] Measurement of the energy of fast neutrons in the presence of gamma rays using a NaI(Tl) and a plastic scintillator
    Li, Xiaobing
    Wang, Zhonghai
    Lv, Huanwen
    Wei, Shuping
    Liu, Jiajia
    Wang, Yudong
    Fan, Xing
    Zhou, Rong
    Yang, Chaowen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 976 (976):
  • [8] Optimization of Plastic Scintillator for Detection of Gamma-Rays: Simulation and Experimental Study
    Min, Sujung
    Kim, Youngsu
    Ko, Kwang-Hoon
    Seo, Bumkyung
    Cheong, JaeHak
    Roh, Changhyun
    Hong, Sangbum
    CHEMOSENSORS, 2021, 9 (09)
  • [9] THE LIGHT RESPONSE OF PLASTIC SCINTILLATOR AND THE CALIBRATION OF LARGE ARRAYS
    CEBRA, DA
    WILSON, WK
    VANDERMOLEN, A
    WESTFALL, GD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 313 (03): : 367 - 372
  • [10] Validation of the FLUKA code to simulate response functions of organic liquid scintillator for high-energy neutrons
    Ghavami, Ahad
    Tajik, Mojtaba
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (02)