Light-transport incorporated plastic scintillator response to prompt gamma-rays for use in range verification of proton therapy

被引:0
|
作者
Shahsavari, A. [1 ]
Ghal-Eh, N. [1 ]
Najafabadi, R. Izadi [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Phys, POB 91775-1436, Mashhad, Iran
关键词
Proton therapy; Prompt gamma rays (PGs); Range verification; Bragg peak; MCNPX; PTRAC; PHOTRACK; CROSS-SECTIONS; BOMBARDMENT; RADIATION;
D O I
10.1016/j.nima.2023.168036
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, the prompt gamma-rays (PGs) produced during the interactions of proton beams of various energies have been investigated using the MCNPX2.6 Monte Carlo code. Having considered a detection setup consisting of a thick lead collimator and a commercial plastic scintillator, the event-by-event data, generated by the PTRAC card of the MCNPX code, when the scintillator is exposed to PGs have been extracted before they are used in a dedicated light transport code, PHOTRACK. The plastic scintillator response when it is moved along the phantom axis determines the flux variation of proton-induced PGs which can be further related to the longitudinal deposition energy profile of protons, i.e., the Bragg curve. The present study shows that the Bragg peak location is similar to 3.7 cm after the PG peak for different proton energies of interest. The uncertainty in the Bragg peak location data is about 0.02 cm which can be improved by taking into account the precise electron-transport simulation details.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Modelling plastic scintillator response to gamma rays using light transport incorporated FLUKA code
    Kohan, M. Ranjbar
    Etaati, G. R.
    Ghal-Eh, N.
    Safari, M. J.
    Afarideh, H.
    Asadi, E.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (05) : 864 - 867
  • [2] Validation of Nuclear Reaction Models to Simulate Proton Therapy Range Verification Using Prompt Gamma-Rays
    Verburg, J.
    Shih, H.
    Seco, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3860 - 3860
  • [3] Range verification of proton radiotherapy with prompt gamma rays
    Lau, Andy
    Chen, Yong
    Ahmad, Salahuddin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 507 - 514
  • [4] Energy- and time-resolved detection of prompt gamma-rays for proton range verification
    Verburg, Joost M.
    Riley, Kent
    Bortfeld, Thomas
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20): : L37 - L49
  • [5] Prompt gamma detection for range verification in proton therapy
    Kurosawa, Shunsuke
    Kubo, Hidetoshi
    Ueno, Kazuki
    Kabuki, Shigeto
    Iwaki, Satoru
    Takahashi, Michiaki
    Taniue, Kojiro
    Higashi, Naoki
    Miuchi, Kentaro
    Tanimori, Toru
    Kim, Dogyun
    Kim, Jongwon
    CURRENT APPLIED PHYSICS, 2012, 12 (02) : 364 - 368
  • [6] Range Verification using Prompt Gamma-rays with Energy Spectral Analysis in Geant4 Based Proton Therapy Simulation
    Aso, Tsukasa
    Oke, Hiroki
    Nishio, Teiji
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [7] Pinhole Camera Measurements of Prompt Gamma-rays for Detection of Beam Range Variation in Proton Therapy
    Kim, Dogyun
    Yim, Heejung
    Kim, Jong-Won
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1673 - 1676
  • [8] Proposal of Range Verification Method for Carbon Therapy using Prompt Gamma-rays over 10 MeV
    Kimura, Shota
    Kawai, Hideyuki
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [9] Comparison of Prompt Gamma and PET Imaging for Range Verification in Proton Therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] A simulation study investigating a Cherenkov material for use with the prompt gamma range verification in proton therapy
    Lau, Andy
    Ahmad, Salahuddin
    Chen, Yong
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (04) : 565 - 582