Feasibility of Hyperpolarized 129Xe MRI in Primary Ciliary Dyskinesia

被引:1
|
作者
Wee, W. [1 ]
Zanette, B. [1 ]
Munidasa, S. [1 ]
Dumas, M. [1 ]
Braganza, S. [1 ]
Li, D. [1 ]
Ratjen, F. [1 ]
Santyr, G. [1 ]
Dell, S. [2 ]
机构
[1] Hosp Sick Children, Toronto, ON, Canada
[2] BC Childrens Hosp, Vancouver, BC, Canada
关键词
D O I
10.1183/13993003.congress-2022.2204
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
2204
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Lung Abnormalities Detected with Hyperpolarized 129Xe MRI in Patients with Long COVID
    Grist, James T.
    Collier, Guilhem J.
    Walters, Huw
    Kim, Minsuok
    Chen, Mitchell
    Abu Eid, Gabriele
    Laws, Aviana
    Matthews, Violet
    Jacob, Kenneth
    Cross, Susan
    Eves, Alexandra
    Durrant, Marianne
    McIntyre, Anthony
    Thompson, Roger
    Schulte, Rolf F.
    Raman, Betty
    Robbins, Peter A.
    Wild, Jim M.
    Fraser, Emily
    Gleeson, Fergus
    RADIOLOGY, 2022, 305 (03) : 709 - 717
  • [32] Comparison of ventilation defects quantified by Technegas SPECT and hyperpolarized 129Xe MRI
    Radadia, Nisarg
    Friedlander, Yonni
    Priel, Eldar
    Konyer, Norman B.
    Huang, Chynna
    Jamal, Mobin
    Farncombe, Troy
    Marriott, Christopher
    Finley, Christian
    Agzarian, John
    Dolovich, Myrna
    Noseworthy, Michael D.
    Nair, Parameswaran
    Shargall, Yaron
    Svenningsen, Sarah
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [33] HYPERPOLARIZED 129XE PULMONARY MRI TO MONITOR CYSTIC FIBROSIS PULMONARY EXACERBATIONS
    Rayment, J. H.
    Couch, M.
    McDonald, N.
    Kanhere, N.
    Manson, D.
    Santyr, G.
    Ratjen, F.
    PEDIATRIC PULMONOLOGY, 2018, 53 : 235 - 235
  • [34] Reproducibility of Hyperpolarized 129Xe MRI Ventilation Defect Percent in Severe Asthma to Evaluate Clinical Trial Feasibility
    Svenningsen, Sarah
    McIntosh, Marrissa
    Ouriadov, Alexei
    Matheson, Alexander M.
    Konyer, Norman B.
    Eddy, Rachel L.
    McCormack, David G.
    Noseworthy, Michael D.
    Nair, Parameswaran
    Parraga, Grace
    ACADEMIC RADIOLOGY, 2021, 28 (06) : 817 - 826
  • [35] Hyperpolarized 129Xe MRI at low field: Current status and future directions
    Perron, Samuel
    Ouriadov, Alexei
    JOURNAL OF MAGNETIC RESONANCE, 2023, 348
  • [36] Highly and Adaptively Undersampling Pattern for Pulmonary Hyperpolarized 129Xe Dynamic MRI
    Xiao, Sa
    Deng, He
    Duan, Caohui
    Xie, Junshuai
    Li, Haidong
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (05) : 1240 - 1250
  • [37] In Vivo Lung Morphometry of Lymphangioleiomyomatosis Using Hyperpolarized 129Xe Diffusion MRI
    Bdaiwi, A. S.
    Hossain, M. M.
    Willmering, M. M.
    Wang, H.
    Gupta, N.
    McCormack, F. X.
    Woods, J. C.
    Cleveland, Z., I
    Walkup, L.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [38] Extending Semiautomatic Ventilation Defect Analysis for Hyperpolarized 129Xe Ventilation MRI
    He, Mu
    Kaushik, S. Sivaram
    Robertson, Scott H.
    Freeman, Matthew S.
    Virgincar, Rohan S.
    McAdams, H. Page
    Driehuys, Bastiaan
    ACADEMIC RADIOLOGY, 2014, 21 (12) : 1530 - 1541
  • [39] In vivo MRI using real-time production of hyperpolarized 129Xe
    Driehuys, Bastiaan
    Pollaro, Jim
    Cofer, Gary P.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 14 - 20
  • [40] A portable ventilator with integrated physiologic monitoring for hyperpolarized 129Xe MRI in rodents
    Virgincar, Rohan S.
    Dahlke, Jerry
    Robertson, Scott H.
    Morand, Nathann
    Qi, Yi
    Degan, Simone
    Driehuys, Bastiaan
    Nouls, John C.
    JOURNAL OF MAGNETIC RESONANCE, 2018, 295 : 63 - 71