Determination of Benzoyl Peroxide in Flour Brightener with Microfluidic Chip-Based Flow-Injection Chemiluminescence

被引:6
|
作者
Wang, Xiaozhang [1 ]
Wang, Chaohui [1 ]
Zhang, Qunming [1 ]
Wang, Jing [1 ]
Zheng, Tengfei [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
关键词
Microfluidic chip; Chemiluminescence; Flow injecting; Benzoyl peroxide; SYSTEM;
D O I
10.14233/ajchem.2013.13248
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Benzoyl peroxide (BPO) in flour brightener was determined with chip-based chemiluminescence reaction. The microfluidic chip was fabricated with PDMS using MEMS techniques and the flow-injection chemiluminescence experiments were performed. The conditions of experiments including sample inject and flow-rate were selected and optimized according to their different influences on detect results. The standard curve of relative chemiluminescence intensity and benzoyl peroxide concentration was constructed from the reaction of benzoyl peroxide and luminol solutions with specific concentration, respectively. The experimental results indicate that a good linear relation is formed between the chemiluminescence intensity and benzoyl peroxide concentration within 10(-6)-10(-8) g mL(-1). The detection limit is about 2 x 10(-9) g mL(-1) in benzoyl peroxide solution. At last, flour brightener samples bought from market were tested with this microfluidic chip system. The result was consistent well with the content of brightener tag. Some important topics of integrated chip were discussed including inject pump, active mixer and rnicroheater.
引用
收藏
页码:1942 / 1946
页数:5
相关论文
共 50 条
  • [21] A Flow-Injection Chemiluminescence Determination of Formaldehyde in Textiles
    Kanwal, Shamsa
    Ma, Qiang
    Fu, Xiaohong
    Yuan, Pingfan
    Su, Xingguang
    SPECTROSCOPY LETTERS, 2010, 43 (02) : 84 - 90
  • [22] Determination of diethylstilboestrol by flow-injection chemiluminescence immunoassay
    Wang, S.
    Li, L.
    Liang, Y.
    Zhao, Y.
    LUMINESCENCE, 2008, 23 (02) : 100 - 100
  • [23] Microfluidic flow-injection aptamer-based chemiluminescence platform for sulfadimethoxine detection
    Wang, Yanwei
    Rink, Simone
    Baeumner, Antje J.
    Seidel, Michael
    MICROCHIMICA ACTA, 2022, 189 (03)
  • [24] Flow-injection Chemiluminescence Sensor for Hydrogen Peroxide with Immobilized Reagents
    Bao Xin LI
    Wei QIN
    Zhu Jun ZHANG (Department of Chemistry
    Chinese Chemical Letters, 1998, (05) : 471 - 472
  • [25] Flow-injection chemiluminescence sensor for hydrogen peroxide with immobilized reagents
    Li, BX
    Qin, W
    Zhang, ZJ
    CHINESE CHEMICAL LETTERS, 1998, 9 (05) : 471 - 472
  • [26] Chemiluminescence determination of potassium bromate in flour based on flow injection analysis
    Yan, Zhengyu
    Zhang, Zhengwei
    Yu, Yan
    Liu, Zhen
    Chen, Jianqiu
    FOOD CHEMISTRY, 2016, 190 : 20 - 24
  • [27] Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis
    Baecker, M.
    Rakowski, D.
    Poghossian, A.
    Biselli, M.
    Wagner, P.
    Schoening, M. J.
    JOURNAL OF BIOTECHNOLOGY, 2013, 163 (04) : 371 - 376
  • [28] DETERMINATION OF HYDROGEN-PEROXIDE IN SEA-WATER BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    PRICE, D
    WORSFOLD, PJ
    MANTOURA, RFC
    ANALYTICA CHIMICA ACTA, 1994, 298 (01) : 121 - 128
  • [29] FLOW-INJECTION DETERMINATION OF BENZIMIDAZOLE FUNGICIDES IN NATURAL WATERS WITH COPPER(II)-HYDROGEN PEROXIDE CHEMILUMINESCENCE
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL LETTERS, 2010, 43 (04) : 603 - 617
  • [30] Flow-injection chemiluminescence determination of melamine in urine and plasma
    Tang, Xiaoshuang
    Shi, Xiyan
    Tang, Yuhai
    Yue, Zhongjin
    He, Qiqi
    LUMINESCENCE, 2012, 27 (03) : 229 - 233