Determination of Benzoyl Peroxide in Flour Brightener with Microfluidic Chip-Based Flow-Injection Chemiluminescence

被引:6
|
作者
Wang, Xiaozhang [1 ]
Wang, Chaohui [1 ]
Zhang, Qunming [1 ]
Wang, Jing [1 ]
Zheng, Tengfei [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
关键词
Microfluidic chip; Chemiluminescence; Flow injecting; Benzoyl peroxide; SYSTEM;
D O I
10.14233/ajchem.2013.13248
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Benzoyl peroxide (BPO) in flour brightener was determined with chip-based chemiluminescence reaction. The microfluidic chip was fabricated with PDMS using MEMS techniques and the flow-injection chemiluminescence experiments were performed. The conditions of experiments including sample inject and flow-rate were selected and optimized according to their different influences on detect results. The standard curve of relative chemiluminescence intensity and benzoyl peroxide concentration was constructed from the reaction of benzoyl peroxide and luminol solutions with specific concentration, respectively. The experimental results indicate that a good linear relation is formed between the chemiluminescence intensity and benzoyl peroxide concentration within 10(-6)-10(-8) g mL(-1). The detection limit is about 2 x 10(-9) g mL(-1) in benzoyl peroxide solution. At last, flour brightener samples bought from market were tested with this microfluidic chip system. The result was consistent well with the content of brightener tag. Some important topics of integrated chip were discussed including inject pump, active mixer and rnicroheater.
引用
收藏
页码:1942 / 1946
页数:5
相关论文
共 50 条
  • [1] Microfluidic chip-based flow-injection analysis with high throughput sampling interface
    Fang, Q
    Du, WB
    He, QH
    Fang, ZL
    Micro Total Analysis Systems 2004, Vol 1, 2005, (296): : 195 - 197
  • [2] Chemilummescence microfluidic chip fabricated in PMMA for determination of benzoyl peroxide in flour
    Liu, W
    Zhang, ZJ
    Yang, L
    FOOD CHEMISTRY, 2006, 95 (04) : 693 - 698
  • [3] Flow-injection Chemiluminescence Determination of Catecholamines
    Cheng Xiao ZHANG
    Zhu Jun ZHANG(Department of Chemistry
    (Lu’an Teacher’s College
    ChineseChemicalLetters, 1998, (09) : 843 - 845
  • [4] Flow-injection chemiluminescence determination of fluoroquinolones
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, GA
    Baeyens, WRG
    ANALYTICAL LETTERS, 2000, 33 (06) : 1117 - 1129
  • [5] Flow-injection chemiluminescence determination of catecholamines
    Wolyniec, Elzbieta
    Niedzwiedzka, Urszula
    Kojlo, Anatol
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2007, 35 (02) : 219 - 231
  • [6] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF SULFITE
    ALTAMRAH, SA
    TOWNSHEND, A
    WHEATLEY, AR
    ANALYST, 1987, 112 (06) : 883 - 886
  • [7] Flow-injection chemiluminescence determination of catecholamines
    Huang, JC
    Zhang, CX
    Zhang, ZJ
    CHINESE CHEMICAL LETTERS, 1998, 9 (09) : 843 - 845
  • [8] Determination of norfloxacin by flow-injection chemiluminescence
    Liao, SL
    Xie, ZH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1938 - 1942
  • [9] Determination of hydrogen peroxide in sea water by flow-injection analysis with chemiluminescence detection
    Price, D.
    Worsfold, P. J.
    Fauzi, R.
    Mantoura, C.
    International Sugar Journal, 978
  • [10] A novel method for the determination of fluorescent whitening agent CBS in flour using flow-injection chemiluminescence based on a luminol-urea peroxide system
    He, Gaiyan
    Gao, Ruixia
    Hao, Yi
    Tang, Xiaoshuang
    ANALYTICAL METHODS, 2016, 8 (31) : 6082 - 6088