Research on the delay-line readout for GEM detectors

被引:0
|
作者
Zhou Yi [1 ]
Li Cheng [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
来源
CHINESE PHYSICS C | 2008年 / 32卷
基金
中国国家自然科学基金;
关键词
GEM; delay-line readout; particle detector;
D O I
暂无
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Based on the principles of transmission line and the output signal of GEM detector, a full simulation model of delay-line circuit has been described in this paper. The consistency of simulation results and experimental data shows that the method is very effective for the design of delay-line readout.
引用
收藏
页码:232 / 234
页数:3
相关论文
共 50 条
  • [21] Characteristics of a delay-line readout in a cylindrical drift chamber system
    Barber, R
    Ahmed, MW
    Dzemidzic, M
    Empl, A
    Hungerford, EV
    Lan, KJ
    Wilson, J
    Cooper, MD
    Gagliardi, CA
    Haim, D
    Kim, GJ
    Koetke, DD
    Tribble, RE
    Van Ausdeln, LA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3): : 591 - 598
  • [22] CONSTRUCTION AND APPLICATION OF A DELAY-LINE FOR POSITION READOUT OF WIRE CHAMBERS
    DEGRAAF, EJ
    PAANS, AMJ
    WOLDRING, MG
    SPIJKERVET, WJJ
    NUCLEAR INSTRUMENTS & METHODS, 1979, 166 (02): : 139 - 149
  • [23] A HIGH-RESOLUTION DELAY-LINE READOUT FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, ML
    RAFFANTI, R
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 476 - 485
  • [24] TESTS OF A TIME PROJECTION CHAMBER MODULE WITH DELAY-LINE READOUT
    BUDAGOV, YA
    GLAGOLEV, VV
    OMELYANENKO, AA
    SEMENOV, AA
    HLINKA, V
    POVINEC, P
    SITAR, B
    KLADIVA, E
    SEMAN, M
    SPALEK, J
    ARTYKOV, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 284 (2-3): : 433 - 438
  • [25] LARGE DRIFT TUBE ARRAYS WITH EXTERNAL DELAY-LINE READOUT
    BROLL, C
    CHARVEYS, A
    DECLAIS, Y
    FAVIER, J
    LEBEAU, M
    MOYNOT, M
    PERROT, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03): : 385 - 395
  • [26] RECENT DEVELOPMENTS IN DELAY-LINE READOUT OF MULTIWIRE PROPORTIONAL CHAMBERS
    PEREZMEN.V
    PARKER, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 45 - 50
  • [27] ALTERNATIVE APPROACHES TO DELAY-LINE READOUT FOR MULTIWIRE PROPORTIONAL CHAMBERS
    CIPRIANI, F
    GABRIEL, A
    KOCH, MHJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2): : 286 - 291
  • [28] FPGA implementation of a delay-line readout system for a particle detector
    Seferiadis, G
    Pouchet, M
    Gough, MP
    MEASUREMENT, 2006, 39 (01) : 90 - 99
  • [29] Study of Delay-line Readout for Boron Coated Straw detector
    Yu, Hao
    Gong, Hui
    Wang, Yongqiang
    Wang, Xuewu
    Li, Jianmin
    Li, Yuanjing
    Kang, Kejun
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [30] DUAL TIME TO DIGITAL CONVERTER FOR DELAY-LINE READOUT OF POSITION-SENSITIVE GAS-FILLED DETECTORS
    BERRY, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (05): : 1222 - 1228