Research on the delay-line readout for GEM detectors

被引:0
|
作者
Zhou Yi [1 ]
Li Cheng [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Peoples R China
来源
CHINESE PHYSICS C | 2008年 / 32卷
基金
中国国家自然科学基金;
关键词
GEM; delay-line readout; particle detector;
D O I
暂无
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Based on the principles of transmission line and the output signal of GEM detector, a full simulation model of delay-line circuit has been described in this paper. The consistency of simulation results and experimental data shows that the method is very effective for the design of delay-line readout.
引用
收藏
页码:232 / 234
页数:3
相关论文
共 50 条
  • [1] DELAY-LINE READOUT FOR MULTICELL DETECTORS
    DITTA, J
    KURODA, K
    NEMOZ, C
    SILLOU, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 250 (03): : 539 - 542
  • [2] Study of delay-line readout for GEM detector
    Zhou, Yi
    Li, Cheng
    Sun, Yongjie
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 71 - 76
  • [3] DIRECT TIME DIGITIZING FOR DETECTORS WITH DELAY-LINE READOUT
    BOULIN, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 237 - 239
  • [4] Two-dimensional GEM imaging detector with delay-line readout
    Guedes, GP
    Breskin, A
    Chechik, R
    Vartsky, D
    Bar, D
    Barbosa, AF
    Marinho, PRB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 473 - 483
  • [5] PLANAR DOUBLE DELAY-LINE READOUT TECHNIQUE FOR MICROCHANNEL PLATE DETECTORS
    LAMPTON, M
    SIEGMUND, OHW
    RAFFANTI, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (04) : 1548 - 1549
  • [6] An X-ray imaging device based on a GEM detector with delay-line readout
    Zhou Yi
    Li Cheng
    Sun Yong-Jie
    Shao Ming
    CHINESE PHYSICS C, 2010, 34 (01) : 78 - 82
  • [7] A MICROSTRIP DETECTOR WITH DELAY-LINE READOUT
    BARBOSA, AF
    RIEKEL, C
    WATTECAMPS, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 667 - 669
  • [8] DELAY-LINE READOUT FOR DRIFT CHAMBERS
    KREHBIEL, H
    WARMING, P
    ELSEN, E
    NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2): : 347 - 351
  • [9] An X-ray imaging device based on a GEM detector with delay-line readout
    周意
    李澄
    孙勇杰
    邵明
    中国物理C, 2010, (01) : 78 - 82
  • [10] DELAY-LINE READOUT FOR PROPORTIONAL CHAMBERS
    RINDI, A
    PEREZMEN.V
    WALLACE, RI
    NUCLEAR INSTRUMENTS & METHODS, 1970, 77 (02): : 325 - +