Second Spine: a Device to relieve stresses on the upper body during loaded walking

被引:0
|
作者
Park, Joon-Hyuk [1 ]
Zanotto, Damiano [1 ]
Vashista, Vineet [1 ]
Jin, Xin [1 ]
Stegall, Paul [1 ]
Agrawal, Sunil K. [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
关键词
MEDICAL ASPECTS; MUSCLE-ACTIVITY; CARRIAGE; BACKPACK; CHILDREN; TRUNK; MODES; GAIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The target of this work is to experimentally validate the Second Spine, a wearable device recently developed by our group to transfer forces from shoulder to pelvis during loaded walking. A key-feature of the Second Spine compared to traditional framed backpacks is the adjustable stiffness of its structure, which allows the wearer to change the load-bearing behavior of the device. In line with previous studies on loaded walking, we investigate biomechanical and physiological variables on a small group of young healthy subjects, as they walked on a treadmill under 3 different conditions: free walking, walking with a backpack of 25% of subject's Body Weight (BW), and walking with the same backpack while wearing the device. Results indicate that wearing the Second Spine significantly reduces the pressure on shoulders and induces smaller deviations from unloaded walking in terms of gait timing and stride length. The activations of the rectus femoris and the gastrocnemius muscles, along with the kinematics of the knee joint, provide indirect evidence that dynamic loads were rigidly transmitted from the shoulder to the waist. We discuss how these preliminary findings might be relevant for the prevention of injuries related to load carriage, and how they set important guidelines for the next generation of the Second Spine.
引用
收藏
页码:689 / 694
页数:6
相关论文
共 50 条
  • [41] Metabolic and Biomechanical Effects of Velocity and Weight Support Using a Lower-Body Positive Pressure Device During Walking
    Grabowski, Alena M.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (06): : 951 - 957
  • [42] Impact of the "Sling Shot" Supportive Device on Upper-Body Neuromuscular Activity during the Bench Press Exercise
    Wojdala, Grzegorz
    Golas, Artur
    Krzysztofik, Michal
    Lockie, Robert George
    Roczniok, Robert
    Zajac, Adam
    Wilk, Michal
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (20) : 1 - 12
  • [43] The effect of arm restriction on dynamic stability and upper-body responses to lateral loss of balance during walking: an observational study
    Rosenblum, Uri
    Lavi, Adi
    Fischer, Arielle G.
    Parmet, Yisrael
    Haim, Amir
    Handelzalts, Shirley
    ROYAL SOCIETY OPEN SCIENCE, 2024, 11 (12):
  • [44] Effects of Lumbar Spine Assemblies and Body-Borne Equipment Mass on Anthropomorphic Test Device Responses During Drop Tests
    Aggromito, Daniel
    Jaffrey, Mark
    Chhor, Allen
    Chen, Bernard
    Yan, Wenyi
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (10):
  • [45] The effect of an on-body personal lift-assist device (Jaipur Belt) on spine kinetics during a functional lift task
    Shyam Krishnan, K.
    Nayak, Megha M.
    Eapen, Charu
    Thomas, Betty
    Gautam, Karan
    JOURNAL OF PUBLIC HEALTH-HEIDELBERG, 2024, 32 (10): : 2037 - 2043
  • [46] The effects of a posterior superior iliac spine support device on upper trunk acceleration during gait in individuals with flat lumbar back posture
    Shin, Sun-Shil
    Shin, Gyu-Cheol
    Kim, Do-Hee
    Sim, Hyo-Min
    Jeong, Jin-Gyeong
    Yoo, Won-Gyu
    TECHNOLOGY AND HEALTH CARE, 2018, 26 (05) : 873 - 878
  • [47] Repeated Exposure to Forward Support-Surface Perturbation During Overground Walking Alters Upper-Body Kinematics and Step Parameters
    Inkol, Keaton A.
    Huntley, Andrew H.
    Vallis, Lori Ann
    JOURNAL OF MOTOR BEHAVIOR, 2019, 51 (03) : 318 - 330
  • [48] Influence of lumbar spine rhythms and intra-abdominal pressure on spinal loads and trunk muscle forces during upper body inclination
    Arshad, Rizwan
    Zander, Thomas
    Dreischarf, Marcel
    Schmidt, Hendrik
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (04) : 333 - 338
  • [49] Effect of preferred walking speed on the upper body range of motion and mechanical work during gait before and after spinal fusion for patients with idiopathic scoliosis
    Delpierre, Yannick
    Vernet, Philippe
    Surdel, Annie
    CLINICAL BIOMECHANICS, 2019, 70 : 265 - 269
  • [50] Early-phase strength gains during traditional resistance training compared with an upper-body air-resistance training device
    McGinley, Cian
    Jensen, Randall L.
    Byrne, Ciaran A.
    Shafat, Amir
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2007, 21 (02) : 621 - 627