Femoral Component Rotation in Total Knee Arthroplasty Using a Tibia-First, Gap-Balancing, "Functional Alignment" Technique

被引:5
|
作者
Dlaska, Constantin [1 ]
Ismailidis, Petros [1 ,2 ,3 ]
Doma, Kenji [1 ,2 ]
Brandon, Benjamin [1 ]
Wilkinson, Matthew [1 ,4 ]
Hazratwala, Kaushik [1 ,5 ]
机构
[1] Orthopaed Res Inst Queensland ORIQL, Townsville, Qld 4812, Australia
[2] James Cook Univ, Coll Hlth Care Sci, Div Trop Hlth & Med, Douglas, Qld 4811, Australia
[3] Univ Hosp Basel, Dept Orthopaed & Traumatol, Spitalstr 21, CH-4031 Basel, Switzerland
[4] Univ Tasmania, Sch Med, Med Sci Precinct, 17 Liverpool St, Hobart, Tas 7000, Australia
[5] James Cook Univ, Div Med & Dent, Douglas, Qld 4811, Australia
关键词
TKA; total knee arthroplasty; rotational alignment; kinematic alignment; functional alignment; gap balancing;
D O I
10.3390/jcm11226680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The purpose of this study was to describe the femoral component rotation in total knee arthroplasty (TKA) using a tibia-first, gap-balancing, "functional alignment" technique. Methods: Ninety-seven patients with osteoarthritis received a TKA using computer navigation. The tibial resection was performed according to the kinematic alignment (KA) principles, while the femoral rotation was set according to the gap-balancing technique. Preoperative MRIs and intraoperative resection depth data were used to calculate the following rotational axes: the transepicondylar axis (TEA), the posterior condylar axis (PCA) and the prosthetic posterior condylar axis (rPCA). The angles between the PCA and the TEA (PCA/TEA), between the rPCA and the PCA (rPCA/PCA) and between the rPCA and the TEA (rPCA/TEA) were measured. Data regarding patellar maltracking and PROMs were collected for 24 months postoperatively. Results: The mean PCA/TEA, rPCA/TEA and rPCA/PCA angles were -5.1 degrees +/- 2.1 degrees, -4.8 degrees +/- 2.6 degrees and -0.4 degrees +/- 1.7 degrees, respectively (the negative values denote the internal rotation of the PCA to the TEA, rPCA to TEA and rPCA to PCA, respectively). There was no need for lateral release and no cases of patellar maltracking. Conclusions: A tibia-first, gap-balancing, "functional alignment" approach allows incorporating a gap-balancing technique with kinematic principles. Sagittal complexities in the proximal tibia (variable medial and lateral slopes) can be accounted for, as the tibial resection is completed prior to setting the femoral rotation. The prosthetic femoral rotation is internally rotated relative to the TEA, almost parallel to the PCA, similar to the femoral rotation of the KA-TKA technique. This technique did not result in patellar maltracking.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Comparison between two computer-assisted total knee arthroplasty: gap-balancing versus measured resection technique
    Domenico Tigani
    G. Sabbioni
    R. Ben Ayad
    M. Filanti
    N. Rani
    N. Del Piccolo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1304 - 1310
  • [32] Can tibia-first total knee arthroplasty using computer-assisted system improve anterior and posterior knee stability?
    Takahashi, Tsuneari
    Sugimoto, Kazutaka
    Ae, Ryusuke
    Saito, Tomohiro
    Kimura, Yuya
    Kubo, Tatsuya
    Handa, Mikiko
    Takeshita, Katsushi
    TECHNOLOGY AND HEALTH CARE, 2022, 30 (05) : 1147 - 1154
  • [33] Reproducibility of coronal plane alignment of the knee (CPAK) using tibia-first restricted inverse kinematic alignment
    Amer Hallak
    Ittai Shichman
    Itay Ashkenazi
    Amal Khoury
    Yaniv Warschawski
    Aviram Gold
    Nimrod Snir
    Archives of Orthopaedic and Trauma Surgery, 145 (1)
  • [34] The effect of femoral component external rotation on tibial rotation in total knee arthroplasty
    Sherwood, CP
    Zhang, AX
    Petrella, AJ
    Miller, MC
    Berger, RA
    Rubash, HE
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 311 - 312
  • [35] High three-dimensional accuracy of component placement and lower limb alignment using a robotic arm-assisted system and gap-balancing instrument in total knee arthroplasty
    Diquattro, Emanuele
    Prill, Robert
    Salzmann, Mikhail
    Traina, Francesco
    Becker, Roland
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (03) : 685 - 692
  • [36] Patient Variation Limits Use of Fixed References for Femoral Rotation Component Alignment in Total Knee Arthroplasty
    Twiggs, Joshua G.
    Dickison, David M.
    Kolos, Elizabeth C.
    Wilcox, Caitlin E.
    Roe, Justin P.
    Fritsch, Brett A.
    McMahon, Stephen J.
    Miles, Brad P.
    Ruys, Andrew J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (01): : 67 - 74
  • [37] Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty
    Bae, Ji Hoon
    Lee, Ja-Woon
    Kim, Soo-Hyun
    Kim, Sang-Gyun
    Jeon, Young-Sik
    Choi, Jeong Seok
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (02) : 698 - 704
  • [38] Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty
    Ji Hoon Bae
    Ja-Woon Lee
    Soo-Hyun Kim
    Sang-Gyun Kim
    Young-Sik Jeon
    Jeong Seok Choi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 698 - 704
  • [39] DETERMINING THE ROTATIONAL ALIGNMENT OF THE FEMORAL COMPONENT IN TOTAL KNEE ARTHROPLASTY USING THE EPICONDYLAR AXIS
    BERGER, RA
    RUBASH, HE
    SEEL, MJ
    THOMPSON, WH
    CROSSETT, LS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (286) : 40 - 47
  • [40] Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
    Florian Geiger
    Dominik Parsch
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 267 - 270