EFFECTIVENESS OF HYBRYD POWER PLANT WITH ORC SUPPLIED BY STEAM PRODUCED IN A LOW-TEMPERATURE BIOMASS BOILER

被引:0
|
作者
Nowak, Wladyslaw [1 ]
Borsukiewicz-Gozdur, Aleksandra [1 ]
Stachel, Andrzej A. [1 ]
机构
[1] Tech Univ Szczecin, Katedra Tech Cieplnej, PL-70310 Szczecin, Poland
来源
RYNEK ENERGII | 2008年 / 05期
关键词
biomass; power plant with organic fluid; ORC;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the paper presented has been the assessment of the effectiveness of operation of a power plant with organic fluid as a working fluid where turbine is fed with saturated steam produced in a low-temperature boiler fired with biomass. A specified evaporation temperature of a substance, which is a working fluid in the cycle, corresponds to evaporation temperature in the boiler. Calculations have been completed for four evaporation temperatures of working fluid T1n (103, 108, 113, 118 degrees C) for selected organic substances. Discussed power plant is a hybrid plant where the heating process of working fluid is supported by the low temperature source of waste heat. Obtained results of calculations have been compared with the results of calculations of a power plant, where saturated steam was supplied directly from the boiler, with a possibility of condensate heating by a relevant low temperature heat source. Assessment of particular cases of the power plant has been conducted in comparative conditions of heat supply from the boiler with nominal capacity of =2000kW, whereas the condensation process in respective power plants is realised independently of applied circulation fluid and is executed at a pressure corresponding to temperature of 30 degrees C.
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [41] Feasibility study of a low-temperature geothermal power plant for multiple economic scenarios
    Van Erdeweghe, Sarah
    Van Bael, Johan
    Laenen, Ben
    D'haeseleer, William
    ENERGY, 2018, 155 : 1004 - 1012
  • [42] Low-temperature CCS from an IGCC power plant and comparison with physical solvents
    Berstad, David
    Anantharaman, Rahul
    Neksa, Petter
    GHGT-11, 2013, 37 : 2204 - 2211
  • [43] Optimal combined heat-and-power plant for a low-temperature geothermal source
    Van Erdeweghe, Sarah
    Van Bael, Johan
    Laenen, Ben
    D'haeseleer, William
    ENERGY, 2018, 150 : 396 - 409
  • [44] Dynamic simulation of a low-temperature rectification column as part of an IGCC power plant
    Hanke, R
    Hannemann, F
    Sundmacher, K
    CHEMICAL ENGINEERING & TECHNOLOGY, 2003, 26 (11) : 1126 - 1130
  • [45] Low-temperature corrosion in a BFB boiler firing biomass and waste streams - Online measurement technique for monitoring deposit corrosivity
    Vainio, Emil
    Ruozzi, Alessandro
    Kinnunen, Hanna
    Lauren, Tor
    Hupa, Leena
    FUEL, 2024, 371
  • [46] Low-temperature steam reforming of toluene as a biomass tar model compound over biochar-supported catalysts
    Zulqarnain, Soohyun
    Kim, Soohyun
    Chun, Donghyuk
    Yoo, Jiho
    Yoon, Sang Jun
    Kim, Seong-Ju
    Park, Sung-Jin
    BIOCHAR, 2025, 7 (01)
  • [47] Performance comparison and parametric optimization of subcritical Organic Rankine Cycle (ORC) and transcritical power cycle system for low-temperature geothermal power generation
    Zhang Shengjun
    Wang Huaixin
    Guo Tao
    APPLIED ENERGY, 2011, 88 (08) : 2740 - 2754
  • [48] Combined concentrated solar power plant with low-temperature multi-effect distillation
    Al-Addous, Mohammad
    Jaradat, Mustafa
    Bdour, Mathhar
    Dalala, Zakariya
    Wellmann, Johannes
    ENERGY EXPLORATION & EXPLOITATION, 2020, 38 (05) : 1831 - 1853
  • [49] Thermodynamics Analysis of Binary Plant Generating Power from Low-Temperature Geothermal Resource
    Maksuwan, A.
    8TH INTERNATIONAL CONFERENCE ON FUTURE ENVIRONMENT AND ENERGY (ICFEE 2018), 2018, 150
  • [50] LOW-TEMPERATURE WATER-REACTOR FOR DISTRICT HEATING ATOMIC POWER-PLANT
    SKVORTSOV, SA
    SOKOLOV, IN
    KRAUZE, LV
    NIKIPORETZ, YG
    PHILIMONOV, YV
    NUCLEAR TECHNOLOGY, 1978, 38 (02) : 248 - 251