Phase-Cycled Simultaneous Multislice Balanced SSFP Imaging with CAIPIRINHA for Efficient Banding Reduction

被引:16
|
作者
Wang, Yi [1 ]
Shao, Xingfeng [1 ]
Martin, Thomas [1 ]
Moeller, Steen [2 ]
Yacoub, Essa [2 ]
Wang, Danny J. J. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Neurol, Lab FMRI Technol LOFT, Los Angeles, CA 90024 USA
[2] Univ Minnesota, Ctr Magnet Resonance Res, Minneapolis, MN USA
关键词
simultaneous multi-slice (SMS); controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); balanced steady-state free precession (bSSFP); banding reduction; STATE FREE PRECESSION; MAGNETIC-RESONANCE; SIGNAL; FMRI; REMOVAL; TESLA; ECHO; MRI;
D O I
10.1002/mrm.26076
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To present a time-efficient technique for banding reduction in balanced steady-state free precession (bSSFP) imaging using phase-cycled simultaneous multislice (SMS) acquisition with CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration). Theory: The proposed technique exploits the inherent phase modulation of SMS imaging with CAIPIRINHA to acquire multiple phase-cycled images, which can be combined for efficient banding reduction within the same scan time of a single-band bSSFP scan. Methods: Bloch equation simulation, phantom and in vivo brain, abdominal and cardiac imaging experiments were performed on healthy volunteers at 3T using multi-channel head and body array coils with SMS acceleration factors of two to four. The performance of banding reduction was quantitatively evaluated based on the percent ripple of signal distribution and signal-to-noise ratio (SNR) efficiency in both phantom and human studies. Results: The banding artifact was successfully removed or suppressed using phase-cycled SMS bSSFP imaging across SMS factors of two to four. The performance of banding reduction improved with higher SMS factors along with increased SNR efficiency. Conclusion: Phase-cycled SMS bSSFP with CAIPIRINHA is a promising technique for efficient band reduction in bSSFP without prolonged scan time. Further evaluation of this technique in clinical applications is warranted. (C) 2015 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1764 / 1774
页数:11
相关论文
共 47 条
  • [41] Feasibility study of highly accelerated phase-sensitive inversion recovery myocardial viability imaging using simultaneous multislice and parallel imaging techniques
    Zhang, Zhehao
    Sun, Wenbo
    Lan, Lan
    Zheng, Yuan
    Xu, Jian
    Du, Yiping
    Xu, Haibo
    Chen, Qun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (06) : 1964 - 1972
  • [42] Scan time reduction for readout-segmented EPI using simultaneous multislice acceleration: Diffusion-weighted imaging at 3 and 7 Tesla
    Frost, Robert
    Jezzard, Peter
    Douaud, Gwenaelle
    Clare, Stuart
    Porter, David A.
    Miller, Karla L.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (01) : 136 - 149
  • [43] Scan Time Reduction in Intravoxel Incoherent Motion Diffusion-Weighted Imaging and Diffusion Kurtosis Imaging of the Abdominal Organs: Using a Simultaneous Multislice Technique With Different Acceleration Factors
    Xu, Hui
    Zhang, Nan
    Yang, Da-Wei
    Ren, Ahong
    Ren, Hao
    Zhang, Qian
    Zhu, Jin-Xia
    Li, Gui-Jin
    Yang, Zheng-Han
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (04) : 507 - 515
  • [44] Scan time reduction in diffusion-weighted imaging of the pancreas using a simultaneous multislice technique with different acceleration factors: How fast can we go?
    Jana Taron
    Petros Martirosian
    Thomas Kuestner
    Nina F. Schwenzer
    Ahmed Othman
    Jakob Weiß
    Mike Notohamiprodjo
    Konstantin Nikolaou
    Christina Schraml
    European Radiology, 2018, 28 : 1504 - 1511
  • [45] Scan time reduction in diffusion-weighted imaging of the pancreas using a simultaneous multislice technique with different acceleration factors: How fast can we go?
    Taron, Jana
    Martirosian, Petros
    Kuestner, Thomas
    Schwenzer, Nina F.
    Othman, Ahmed
    Weiss, Jakob
    Notohamiprodjo, Mike
    Nikolaou, Konstantin
    Schraml, Christina
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1504 - 1511
  • [46] A SEmi-Adiabatic Matched-Phase Spin Echo (SEAMS) PINS Pulse-Pair for B1-Insensitive Simultaneous Multislice Imaging
    Feldman, Rebecca E.
    Islam, Haisam M.
    Xu, Junqian
    Balchandani, Priti
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 709 - 717
  • [47] Metal-free polymer photocatalysts for efficient gas-phase reduction of atmospheric CO2 and simultaneous H2O2 production
    Wu, Wei
    Chen, Mantao
    Feng, Chunyuan
    Li, Waner
    Zhang, Tingting
    Zeng, Chao
    Wang, Bo
    Zhong, Lixiang
    Dai, Chunhui
    GREEN CHEMISTRY, 2025, 27 (10) : 2766 - 2775