Resolving the clinical acuity categories "hand motion" and "counting fingers" using the Freiburg Visual Acuity Test (FrACT)

被引:486
|
作者
Lange, C. [1 ]
Feltgen, N. [1 ]
Junker, B. [1 ]
Schulze-Bonsel, K. [1 ]
Bach, M. [1 ]
机构
[1] Univ Freiburg, Dept Ophthalmol, D-79106 Freiburg, Germany
关键词
Visual acuity; Low-vision assessment; Psychophysics; CHART; RELIABILITY;
D O I
10.1007/s00417-008-0926-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose The Freiburg Visual Acuity Test (FrACT) has been suggested as a promising test for quantifying the visual acuity (VA) of patients with very low vision, a condition often classified using the semi-quantitative clinical scale "counting fingers" (CF), "hand motion" (HM), "light perception" (LP) and "no light perception". The present study was designed to assess FrACT performance in a sizable number of CF, HM, and LP patients in order to generate a setting for future clinical studies in the low vision range. Methods We examined a total of 41 patients ( LP, n=11; CF, n=15; HM, n=15) with various eye diseases ( e. g., diabetic retinopathy, ARMD), covering the clinical VA scale from LP to CF. The FrACT optotypes were presented at a distance of 50 cm on a 17-inch LCD monitor with four random orientations. After training, two FrACT measurements ( test and retest) were taken, each comprising 30 trials. Results FrACT measures reproducibly the VA of CF and HM patients. In CF patients, FrACT resulted in a mean logMAR=1.98 +/- 0.24 (corresponding to a decimal VA of 0.010), for HM in a mean logMAR=2.28 +/- 0.15 (corresponding to a decimal VA of 0.0052). In all LP patients the FrACT values were close to what would be obtained by random guessing. The mean test-retest 95% confidence interval was 0.21 logMAR for CF patients and 0.31 logMAR for HM respectively. Test-retest variability declined from 24 to 30 trials, showing that at least 30 trials are necessary. Conclusion FrACT can reproducibly quantify VA in the CF and HM range. We observed a floor effect for LP, and it was not quantifiable further. Quantitative VA measures are thus obtainable in the very low-vision range using FrACT.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [21] Intelligent Visual Acuity Estimation System With Hand Motion Recognition
    Chiu, Chun-Jie
    Tien, Yu-Chieh
    Feng, Kai-Ten
    Tseng, Po-Hsuan
    IEEE TRANSACTIONS ON CYBERNETICS, 2021, 51 (12) : 6226 - 6239
  • [22] The automatic 'Freiburg Visual Acuity Test' used before and after cataract surgery
    Rover, J
    Bornkessel, HC
    Nisius, A
    Bach, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1996, 209 (05) : 315 - 316
  • [23] A Comparative Clinical Evaluation of Two Visual Acuity Testing Systems: ETDRS vs. FrACT
    Tsai, Linda
    Thomas, Eugenia
    Tarrant, Janice
    Bentow, Stan
    Kasthurirangan, Sanjeev
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [24] Test-retest agreement of the Freiburg visual acuity test in ultra-low vision
    Barone, Samuel
    Dagnelie, Gislin
    Batabyal, Subrata
    Chavala, Sai H.
    Mohanty, Samarendra
    Bach, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [25] Applications of dynamic visual acuity test in clinical ophthalmology
    Wu, Ting-Yi
    Wang, Yue-Xin
    Li, Xue-Min
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (11) : 1771 - 1778
  • [26] Clinical use of an objective nystagmographic visual acuity test
    Gräf, M
    Kaufmann, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S962 - S962
  • [27] Applications of dynamic visual acuity test in clinical ophthalmology
    Ting-Yi Wu
    Yue-Xin Wang
    Xue-Min Li
    International Journal of Ophthalmology, 2021, (11) : 1771 - 1778
  • [28] Motion-Acuity Test for Visual Field Acuity Measurement with Motion-Defined Shapes (FEB, 10.3791/66272, 2024)
    Ninghetto, Marco
    Wieteska, Michal
    Kozak, Anna
    Szulborski, Kamil
    Galecki, Tomasz
    Szaflik, Jacek
    Burnat, Kalina
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (206):
  • [29] Minimum visual acuity: a new cone specific clinical test
    Rabin, Jeff
    Goodroe, Katelyn
    Hood, Alyssa
    Duka, Cara
    Dunmon, Kyle
    Bouaphavong, Darien
    Truong, Thinh
    EYE, 2025, 39 (01) : 195 - 197
  • [30] Normal values for unaided visual acuity in children using Glascow acuity cards and the Sheridan Gardiner Test
    Gray, LS
    Simmers, AJ
    Sprowart, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3941 - 3941