High Bandwidth Measurement of Partial Discharge Current Pulses Based on the Optimized Needle-plate Electrode System

被引:0
|
作者
Zhang, Chongxing [1 ]
Dong, Ming [1 ]
Ren, Ming [1 ]
Wang, Li [1 ]
Zhou, Jierui [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat Power Equipment, Xian, Peoples R China
关键词
Partial Discharge; Needle-plate Electrode; Wideband measurement; PD detection;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to obtain the nanosecond partial discharge pulse current signal of needle-plate electrode, a new measurement method of wideband PD pulse current is proposed in this paper. By the numerical calculation of current parameters, the optimized needle-plate electrode structure and the accurate finite element simulation, the experimental platform of the fast PD pulse current detection is set up and its bandwidth is up to 1.81GHz. The testing results indicate that, the established detection system has the some advantages, i.e., high sensitivity, good frequency response characteristics, strong anti-disturbance capability and virtually no waveform distortion, which lays the foundation for further researching the relation between the macroscopic PD pulse current waveform and the microcosmic discharge process.
引用
收藏
页码:916 / 919
页数:4
相关论文
共 50 条
  • [41] IMPROVED ELECTRODE SYSTEM FOR POINT-DISCHARGE CURRENT MEASUREMENT IN TREES
    ETTE, AII
    JOURNAL OF GEOMAGNETISM AND GEOELECTRICITY, 1968, 20 (04): : 423 - &
  • [42] An automated microcomputer based partial discharge measurement system
    Ramakrishnan, M
    Suresh, D
    Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 733 - 736
  • [43] A High Sensitivity Partial Discharge Current Measurement Method for the High Voltage IGBT
    Fu, Pengyu
    Jin, Rui
    Zhao, Zhibin
    Wen, Teng
    Wang, Haoyu
    Li, Li
    2017 IEEE SIXTH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2017,
  • [44] Influence of High Frequency Current Transformers Bandwidth on Charge Evaluation in Partial Discharge Measurements
    Rodrigo, A.
    Llovera, P.
    Fuster, V.
    Quijano, A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (05) : 1798 - 1802
  • [45] An Improved Partial Discharge Detection System Based on UV Pulses Detection
    Shen, Zeliang
    Wang, Jingang
    Wei, Gang
    SENSORS, 2020, 20 (17) : 1 - 15
  • [46] Characteristics of laser-induced streamer corona discharge in a needle-to-plate electrode system
    Kanazawa, S
    Ito, T
    Shuto, Y
    Ohkubo, T
    Nomoto, Y
    Mizeraczyk, J
    JOURNAL OF ELECTROSTATICS, 2002, 55 (3-4) : 343 - 350
  • [47] Measurement of Partial Discharge in Needle-Plane Electrode using RC detector, HFCT, and Antenna Sensors
    Ra, Nhet
    Khayam, Umar
    PROCEEDING JOINT INTERNATIONAL CONFERENCE ON ELECTRIC VEHICULAR TECHNOLOGY AND INDUSTRIAL, MECHANICAL, ELECTRICAL, AND CHEMICAL ENGINEERING (ICEVT & IMECE), 2015, : 106 - 111
  • [48] Current sensor optimization based on simulated transfer function under partial discharge pulses
    Nascimento, Douglas
    Refaat, Shady S.
    Loschi, Hermes
    Iano, Yuzo
    Chuma, Euclides
    El-Sayed, Waseem
    Madi, Amr
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 329
  • [49] Partition and Recognition of Partial Discharge Development Stages in Oil-Pressboard Insulation with Needle-Plate Electrodes Under Combined AC-DC Voltage Stress
    Li, Simeng
    Si, Wen
    Li, Qingquan
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (03) : 1781 - 1793
  • [50] High precision optical Current Measurement System based on the Faraday-Effect with a large Bandwidth
    Gerber, Dominic
    Biela, Juergen
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,