A Phantom Study of Regularized Image Reconstruction in PET

被引:0
|
作者
Wilson, Joshua M. [1 ]
Ross, Steven G. [2 ]
Deller, Timothy [2 ]
Asma, Evren [3 ]
Manjeshwar, Ravindra [3 ]
Turkington, Timothy G. [1 ,4 ]
机构
[1] Duke Univ, Grad Program Med Phys, Durham, NC 27710 USA
[2] GE Healthcare, Mol Imaging, Waukesha, WI USA
[3] GE Global Res Ctr, Funct Imaging Lab, Niskayuna, NY USA
[4] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
RESOLUTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Image quality was measured for varied tuning parameters of four penalized likelihood potential functions with reconstructed PET data of multiple hot spheres in a warm background. Statistical image reconstruction with potential functions that penalize differences in neighboring image voxels can produce a smoother image, but large differences that occur at physical boundaries should not be penalized and allowed to form. Over-smoothing PET images with small lesions is especially problematic because it can completely smooth a lesion's intensities into the background. Fourteen 1.0-cm spheres with a 6: 1 radioactivity concentration relative to the warm background were positioned throughout a 40-cm long phantom with a 36x21-cm oval cross section. By varying the tuning parameters, multiple image sets were reconstructed with modified block sequential regularized expectation maximization statistical reconstruction algorithm using 4 potential functions: quadratic, generalized Gaussian, logCosh, and Huber. Regions of interest were positioned on the images, and the image quality was measured as contrast recovery, background variability, and signal-to-noise ratio across the ROIs. This phantom study was used to further narrow the choice of potential functions and parameter values to either improve the image quality of small lesions or avoid deteriorating them at the cost of optimizing reconstruction parameters for other image features. Neither the quadratic or logCosh potentials performed well for small lesion SNR because they either over-smoothed the lesions or under-smoothed the background, respectively. Varying the parameter values for the Huber potential had a proportional effect on the background variability and the sphere signal such that SNR was relatively fixed. Generalized Gaussian simultaneously decreased background variability and increased small lesion contrast recovery that produced SNRs as much as two-times higher than the other potential functions.
引用
收藏
页码:3661 / 3665
页数:5
相关论文
共 50 条
  • [21] A SIMULATION STUDY OF IMAGE-RECONSTRUCTION FOR PET
    PAVLOPOULOS, S
    TZANAKOS, G
    BHATIA, M
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 612 - 613
  • [22] Optimization of high definition PET/CT image reconstruction: A phantom validation for improved quantification
    Binzel, Katherine
    Zhang, Jun
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [23] Deep Learning Reconstruction at CT: Phantom Study of the Image Characteristics
    Higaki, Toru
    Nakamura, Yuko
    Zhou, Jian
    Yu, Zhou
    Nemoto, Takuya
    Tatsugami, Fuminari
    Awai, Kazuo
    ACADEMIC RADIOLOGY, 2020, 27 (01) : 82 - 87
  • [24] IMAGE RECONSTRUCTION IN PET
    Laforest, Richard
    MOMENTO-REVISTA DE FISICA, 2015, (50E): : 22 - 33
  • [25] Image adaptive thresholding in respiratory gated PET/CT: A phantom study
    Didierlaurent, D.
    Jaudet, C.
    Caselles, O.
    Nalis, J.
    Zerdoud, S.
    Dierickx, L. -O.
    Brillouet, S.
    Courbon, F.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (09): : 470 - 477
  • [26] Image quality and detectability in Siemens Biograph PET/MRI and PET/CT systems—a phantom study
    Silje Kjærnes Øen
    Lars Birger Aasheim
    Live Eikenes
    Anna Maria Karlberg
    EJNMMI Physics, 6
  • [27] Performance of Iterative Image Reconstruction in CT of the Paranasal Sinuses: A Phantom Study
    Schulz, B.
    Beeres, M.
    Bodelle, B.
    Bauer, R.
    Al-Butmeh, F.
    Thalhammer, A.
    Vogl, T. J.
    Kerl, J. M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (05) : 1072 - 1076
  • [28] Matched subspace detection for dynamic PET: An ROC phantom study for map reconstruction
    Li, Zheng
    Li, Quanzheng
    Yu, Xiaoli
    Conti, Peter S.
    Leahy, Richard M.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1332 - +
  • [29] Influence of PET reconstruction parameters on the TrueX algorithm A combined phantom and patient study
    Knaeusl, B.
    Rausch, I. F.
    Bergmann, H.
    Dudczak, R.
    Hirtl, A.
    Georg, D.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2013, 52 (01): : 28 - 35
  • [30] RADIOASTRONOMICAL IMAGE RECONSTRUCTION WITH REGULARIZED LEAST SQUARES
    Naghibzadeh, Shahrzad
    Sardarabadi, Ahmad Mouri
    van der Veen, Alle-Jan
    2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 3316 - 3320