Precise Measurement of the Hydrogen Isotope Composition of Phyllosilicates by Continuous Flow Off-Axis Integrated Cavity Output Spectroscopy

被引:8
|
作者
Mering, John A. [1 ]
Barker, Shaun L. L. [1 ]
机构
[1] Univ Waikato, Sch Sci, Hamilton 3240, New Zealand
关键词
GYPSUM HYDRATION WATER; LASER SPECTROSCOPY; CLAY-MINERALS; HYDROTHERMAL SYSTEMS; STABLE-ISOTOPES; WS-CRDS; FRACTIONATION; DELTA-O-18; O-18/O-16; OXYGEN;
D O I
10.1021/acs.analchem.7b04992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New methodology is presented for analyzing hydrogen isotope ratios (D/H) in phyllosilicate minerals by laser absorption spectroscopy. D/H measurements were carried out using an off-axis integrated cavity output spectroscopy (OA-ICOS) instrument operated in a continuous flow configuration. Water was extracted from minerals in a high temperature quartz column and advanced to the analyzer in a dry air carrier gas stream. We report the first D/H measurements by a laser system for serpentine, muscovite, sericite, talc, and biotite, We also measure kaolinite, gypsum, and small volumes of water. Materials, excluding biotite, were calibrated to within 1.5%o of IRMS-measured delta D-VSMOW values, with an average precision of 1.1 parts per thousand. Biotite delta D measurements were up to 10 parts per thousand more positive than established IRMS values, due to partial reduction of evolved waters by Fe in the high temperature column. We provide recommendations for overcoming redox interference for measurements of biotite, and other ferrous materials, by OA-ICOS. Rapid, precise, and accurate analyses were carried out on water volumes as low as 0.25 mu L extracted from minerals. With the exception of talc, the time required for thermal dewatering and measurement is 140 s, which translates into a throughput of up to 6 mineral samples per hour, including replicates. By demonstrating high precision, rapid throughput, low cost, and ease of operation, we provide a tool that should enable researchers at institutions with limited funding to routinely measure D/H in hydrous minerals. The protocols presented herein should also be useful to commercial users seeking to produce high density isotope data sets relevant to exploration of hydrothermal ore deposits and geothermal fields.
引用
收藏
页码:2852 / 2859
页数:8
相关论文
共 50 条
  • [41] A new method for continuous measurement of methane and carbon dioxide in surface waters using off-axis integrated cavity output spectroscopy (ICOS): An example from the Baltic Sea
    Guelzow, Wanda
    Rehder, Gregor
    Schneider, Bernd
    v. Deimling, Jens Schneider
    Sadkowiak, Bernd
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2011, 9 : 176 - 184
  • [42] Measurement of Low-Concentration Water Vapor Based on Off-Axis Integrated Cavity Absorption Spectroscopy
    Yang Huinan
    Chen Ning
    Chen Jun
    ACTA OPTICA SINICA, 2018, 38 (02)
  • [43] Sensitive absorption measurements in the near-infrared region using off-axis integrated cavity output spectroscopy
    Baer, DS
    Paul, JB
    Gupta, M
    O'Keefe, A
    DIODE LASERS AND APPLICATIONS IN ATMOSPHERIC SENSING, 2002, 4817 : 167 - 176
  • [44] Off-axis integrated-cavity-output spectroscopy for trace-gas concentration measurements: modeling and performance
    Maddaloni, Pasquale
    Gagliardi, Gianluca
    Malara, Pietro
    De Natale, Paolo
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2006, 23 (09) : 1938 - 1945
  • [45] Observation and Analysis of Taizhou Atmosphere NH3 Concentration by Off-Axis Integrated Cavity Output Spectroscopy
    Zhang Guo-xian
    Hu Ren-zhi
    Xie Pin-hua
    Wang Feng-yang
    Wang Yi-hui
    Tong Jin-zhao
    Chen Shi-yi
    Li Shu-le
    Qiu Wan-yi
    Liu Wen-qing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (02) : 360 - 367
  • [46] Measurement of δ18O, δ17O, and 17O-excess in Water by Off-Axis Integrated Cavity Output Spectroscopy and Isotope Ratio Mass Spectrometry
    Berman, Elena S. F.
    Levin, Naomi E.
    Landais, Amaelle
    Li, Shuning
    Owano, Thomas
    ANALYTICAL CHEMISTRY, 2013, 85 (21) : 10392 - 10398
  • [47] Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy
    Baer, DS
    Paul, JB
    Gupta, JB
    O'Keefe, A
    APPLIED PHYSICS B-LASERS AND OPTICS, 2002, 75 (2-3): : 261 - 265
  • [48] Design and experiment of re-injection off-axis integrated cavity output spectroscopy technology in 2 μm band
    Zhou Zi-Xin
    Huang Yin-Bo
    Lu Xing-Ji
    Yuan Zi-Hao
    Cao Zhen-Song
    ACTA PHYSICA SINICA, 2019, 68 (12)
  • [49] Modeling the optical field in off-axis integrated-cavity-output spectroscopy using the decentered Gaussian beam model
    Shen, Guofeng
    Chao, Xing
    Sun, Kai
    APPLIED OPTICS, 2018, 57 (11) : 2947 - 2954
  • [50] High-sensitivity off-axis integrated cavity output spectroscopy implementing wavelength modulation and white noise perturbation
    Wang, Jingjing
    Tian, Xing
    Dong, Yang
    Chen, Jiajin
    Tan, Tu
    Zhu, Gongdong
    Chen, Weidong
    Gao, Xiaoming
    OPTICS LETTERS, 2019, 44 (13) : 3298 - 3301