Efficacy of mandibular advancement device in the treatment of obstructive sleep apnea syndrome: A randomized controlled crossover clinical trial

被引:27
|
作者
Duran-Cantolla, Joaquin [1 ,2 ,3 ,4 ,5 ]
Crovetto-Martinez, Rafael [6 ]
Alkhraisat, Mohammad-Hamdan [5 ]
Crovetto, Miguel [7 ]
Municio, Antonio [8 ]
Kutz, Ramon [9 ]
Aizpuru, Felipe [2 ]
Miranda, Erika [2 ]
Anitua, Eduardo [5 ]
机构
[1] Hosp Univ Araba, Sleep Disorders Unit, Vitoria 01009, Spain
[2] Hosp Univ Araba, BioAraba Inst, BS Res Serv, Vitoria 01009, Spain
[3] Univ Basque Country UPV EHU, Fac Med, Madrid, Spain
[4] ISCIII, Ciber Resp Dis CibeRes, Madrid, Spain
[5] Eduardo Anitua Clin & Fdn, Vitoria, Spain
[6] Univ Basque Country EHU, Fac Med & Dent, Dept Stomatol 2, UFI 11 25, Madrid, Spain
[7] Hosp Basurto, Serv ORL, Bilbao, Vizcaya, Spain
[8] Hosp Curces, Serv ORL, Baracaldo, Vizcaya, Spain
[9] Clin Estomatol, Vitoria, Spain
来源
关键词
Obstructive sleep apnea (OSA); mandibular advance device; treatment; efficacy; clinical assay; POSITIVE AIRWAY PRESSURE; ORAL APPLIANCE DESIGN; HYPOPNEA; HYPERTENSION; MANAGEMENT; MORTALITY; FEATURES; MEN;
D O I
10.4317/medoral.20649
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Evaluation of the efficacy and safety of a mandibular advancement device (MAD) (KlearwayTM) in the treatment of mild-to-moderate obstructive sleep apnea and chronic roncopathy. Material and Methods : A randomized, placebo-controlled, double blinded, and crossover clinical trial was conducted. Placebo device (PD) defined as a splint in the centric occlusion that did not induce a mandibular advancement served as a control. The mandible was advanced to the maximum tolerable distance or to a minimum of 65% of the maximum protrusion. After each sequence of treatment, patients were assessed by questionnaires, conventional polysomnography, and objective measurement of snoring at the patient's own home. Results: Forty two patients participated in the study and 38 completed the study. Patients mean age was 46 +/- 9 years and the 79% were males. The mean mandibular advancement was 8.6 +/- 2.8 mm. Patients used the MAD and the PD for 6.4 +2.4 hours and 6.2 +2.0 hours, respectively. Secondary effects (mostly mild) occurred in the 85.7% and the 86.8% of the users of MAD and PD, respectively. The MAD induced a decrease in the apnea-hypopnea index (AHI) from 15.3 +10.2 to 11.9 +15.5. The 50% reduction in the AHI was achieved in the 46.2% and the 18.4% of the patients treated with MAD and PD, respectively. The use of the MAD induced a reduction in the AHI by 3.4 + 15.9 while the PD induced an increase by 10.6 + 26.1. The subjective evaluation of the roncopathy indicated an improvement by the MAD and an increase in the perceptive quality of sleep. However, the objective evaluation of the roncopathy did not show significant improvements. Conclusions: The use of MAD is efficient to reduce the AHI and improve subjectively the roncopathy. MAD could be considered in the treatment of mild-to-moderate OSA and chronic roncopathy.
引用
收藏
页码:E605 / E615
页数:11
相关论文
共 50 条
  • [1] Mandibular advancement device for treatment of obstructive sleep apnea syndrome
    Petitjean, T
    Tejero, MTG
    Langevin, B
    Philit, F
    Robert, D
    REVUE DES MALADIES RESPIRATOIRES, 1999, 16 (04) : 463 - 474
  • [2] Mandibular advancement device for treatment of obstructive sleep apnea syndrome.
    Petitjean, T
    Tejero, MTG
    Langevin, B
    Philit, F
    Robert, D
    REVUE DES MALADIES RESPIRATOIRES, 2000, 17 : S69 - S79
  • [3] Clinical efficacy of prosthetic mandibular advancement on obstructive sleep apnea syndrome
    Ishida, M
    Inoue, Y
    Okamoto, K
    Suto, Y
    Higami, S
    Kawahara, R
    Ryoke, K
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1999, 53 (02) : 323 - 325
  • [4] Clinical study of two mandibular advancement devices in the treatment of Obstructive Sleep Apnea: a pilot randomized controlled trial
    Yu, Liang
    Mao, Ruohui
    Zhang, Chaoyuan
    Zhao, Jing
    Lin, Nengjie
    Sun, Zhe
    Zheng, Yuanna
    BMC ORAL HEALTH, 2024, 24 (01):
  • [5] Efficacy of the mandibular advancement device on obstructive sleep apnea syndrome - a retrospective study
    Ferraz, Pedro Dias
    Borges, Maria Ines
    da Silva, Mariana Ribeiro
    Carvalho, Fatima
    Moita, Joaquim
    Figueiredo, Jose Pedro
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2020, 61 (03): : 117 - 121
  • [6] Comparison of Mandibular Advancement Splint and Tongue Stabilizing Device in Obstructive Sleep Apnea: A Randomized Controlled Trial
    Deane, Sheryn A.
    Cistulli, Peter A.
    Ng, Andrew T.
    Zeng, Biao
    Petocz, Peter
    Darendeliler, M. Ali
    SLEEP, 2009, 32 (05) : 648 - 653
  • [7] Effect of mandibular advancement device in the treatment of obstructive sleep apnea
    Saleh, Yousra
    Fouda, Ahmed
    Morsy, Nesreien El Sayed
    Abdel-Khalek, Elsayed
    Saleh, Abdelbaset
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2022, 71 (03): : 343 - 352
  • [8] Treatment of obstructive sleep apnea using mandibular advancement device
    Nor Aidaniza, Abdul M.
    Fadzlina, Abd K.
    GAZZETTA MEDICA ITALIANA ARCHIVIO PER LE SCIENZE MEDICHE, 2018, 177 (7-8) : 400 - 402
  • [9] Effectiveness of a mandibular advancement device in obstructive sleep apnea patients: a prospective clinical trial
    Marco Pitarch, Rocio
    Selva Garcia, Marina
    Puertas Cuesta, Javier
    Marco Algarra, Jaime
    Fernandez Julian, Enrique
    Fons Font, Antonio
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (07) : 1903 - 1911
  • [10] Effectiveness of a mandibular advancement device in obstructive sleep apnea patients: a prospective clinical trial
    Rocío Marco Pitarch
    Marina Selva García
    Javier Puertas Cuesta
    Jaime Marco Algarra
    Enrique Fernández Julian
    Antonio Fons Font
    European Archives of Oto-Rhino-Laryngology, 2018, 275 : 1903 - 1911