Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars

被引:3
|
作者
Mohamed, Osama A. [1 ]
Khattab, Rania [1 ]
机构
[1] Abu Dhabi Univ, Coll Engn, Abu Dhabi, U Arab Emirates
关键词
CONCRETE SLABS; STRENGTH;
D O I
10.1088/1757-899X/245/3/032064
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Estimating punching shear strength of recycled aggregate reinforced concrete flat slabs
    Truong, Gia Toai
    Roh, Young-Sook
    Huynh, Thanh-Canh
    Nguyen, Trong-Phuoc
    JOURNAL OF STRUCTURAL INTEGRITY AND MAINTENANCE, 2025, 10 (01)
  • [42] Punching of Reinforced Concrete Flat Slabs with Double-Headed Shear Reinforcement
    Ferreira, Mauricio P.
    Melo, Guilherme S.
    Regan, Paul E.
    Vollum, Robert L.
    ACI STRUCTURAL JOURNAL, 2014, 111 (02) : 363 - 374
  • [43] Effect of flexural and shear reinforcement on the punching behavior of reinforced concrete flat slabs
    Mabrouk, Rasha T. S.
    Bakr, Amr
    Abdalla, Hany
    ALEXANDRIA ENGINEERING JOURNAL, 2017, 56 (04) : 591 - 599
  • [44] Calculation of punching shear strength of steel fiber reinforced concrete flat slabs
    Marciukaitis, Gediminas
    Salna, Remigijus
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1110 - 1114
  • [45] Punching Shear Characterization of Steel Fiber-Reinforced Concrete Flat Slabs
    Mohammed A.H.
    Mubarak H.M.
    Hussein A.K.
    Abulghafour T.Z.
    Nassani D.E.
    HighTech and Innovation Journal, 2022, 3 (04): : 483 - 490
  • [46] Punching shear behavior of flat slabs strengthened with fiber reinforced polymer laminates
    El-Salakawy, E
    Soudki, K
    Polak, MA
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (05) : 384 - 392
  • [47] Shear behaviour of one-way high strength plain and FRC slabs reinforced with basalt FRP bars
    Al-Hamrani, Abathar
    Alnahhal, Wael
    COMPOSITE STRUCTURES, 2022, 302
  • [48] Punching Shear Behavior of Fibrous High Strength Concrete Slabs Reinforced with BFRP Bars
    Adnan, Duha
    Falah, Hassan
    CIVIL AND ENVIRONMENTAL ENGINEERING, 2022, 18 (02) : 565 - 580
  • [49] The Maximum Punching Shear Resistance of Flat Slabs
    Halvonik, Jaroslav
    Fillo, L'udovit
    CONCRETE AND CONCRETE STRUCTURES 2013 - 6TH INTERNATIONAL CONFERENCE, SLOVAKIA, 2013, 65 : 376 - 381
  • [50] Punching Shear Resistance of SFRC Flat Slabs with and Without Punching Shear Reinforcement
    Landler, Josef
    Fischer, Oliver
    FIBRE REINFORCED CONCRETE: IMPROVEMENTS AND INNOVATIONS II, BEFIB 2021, 2022, 36 : 492 - 503