The diagnostic accuracy of 18F-FDG PET/CT in diagnosing fracture-related infections

被引:34
|
作者
Lemans, Justin V. C. [1 ,2 ]
Hobbelink, Monique G. G. [3 ]
Ijpma, Frank F. A. [4 ]
Plate, Joost D. J. [1 ]
van den Kieboom, Janna [1 ]
Bosch, Paul [4 ]
Leenen, Luke P. H. [1 ]
Kruyt, Moyo C. [2 ]
Glaudemans, Andor W. J. M. [5 ]
Govaert, Geertje A. M. [1 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Trauma Surg, POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht, Univ Med Ctr Utrecht, Dept Orthoped, Utrecht, Netherlands
[3] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol & Nucl Med, Utrecht, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Dept Trauma Surg, Groningen, Netherlands
[5] Univ Groningen, Univ Med Ctr Groningen, Dept Nucl Med & Mol Imaging, Med Imaging Ctr, Groningen, Netherlands
关键词
Fracture-related infections; F-18-FDG PET; CT; Diagnostic performance; Trauma; Infection; Osteomyelitis; Medical imaging; Nuclear imaging; Diagnosis; Diagnostic accuracy; CHRONIC OSTEOMYELITIS; FDG-PET/CT; FIXATION; CULTURE; PCR;
D O I
10.1007/s00259-018-4218-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose(18)F-Fluorodeoxyglucose positron emission tomography (F-18-FDG PET/CT) is frequently used to diagnose fracture-related infections (FRIs), but its diagnostic performance in this field is still unknown. The aims of this study were: (1) to assess the diagnostic performance of qualitative assessment of F-18-FDG PET/CT scans in diagnosing FRI, (2) to establish the diagnostic performance of standardized uptake values (SUVs) extracted from F-18-FDG PET/CT scans and to determine their associated optimal cut-off values, and (3) to identify variables that predict a false-positive (FP) or false-negative (FN) F-18-FDG PET/CT result.MethodsThis retrospective cohort study included all patients with suspected FRI undergoing F-18-FDG PET/CT between 2011 and 2017 in two level-1 trauma centres. Two nuclear medicine physicians independently reassessed all F-18-FDG PET/CT scans. The reference standard consisted of the result of at least two deep, representative microbiological cultures or the presence/absence of clinical confirmatory signs of FRI (AO/EBJIS consensus definition) during a follow-up of at least 6months. Diagnostic performance in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) was calculated. Additionally, SUVs were measured on F-18-FDG PET/CT scans. Volumes of interest were drawn around the suspected and corresponding contralateral areas to obtain absolute values and ratios between suspected and contralateral areas. A multivariable logistic regression analysis was also performed to identify the most important predictor(s) of FP or FN F-18-FDG PET/CT results.ResultsThe study included 156 F-18-FDG PET/CT scans in 135 patients. Qualitative assessment of F-18-FDG PET/CT scans showed a sensitivity of 0.89, specificity of 0.80, PPV of 0.74, NPV of 0.91 and diagnostic accuracy of 0.83. SUVs on their own resulted in lower diagnostic performance, but combining them with qualitative assessments yielded an AUC of 0.89 compared to an AUC of 0.84 when considering only the qualitative assessment results (p=0.007). F-18-FDG PET/CT performed <1month after surgery was found to be the independent variable with the highest predictive value fora false test result, with an absolute risk of 46% (95% CI 27-66%), compared with 7% (95% CI 4-12%) in patients with F-18-FDG PET/CT performed 1-6months after surgery.ConclusionQualitative assessment of F-18-FDG PET/CT scans had a diagnostic accuracy of 0.83 and an excellent NPV of 0.91 in diagnosing FRI. Adding SUV measurements to qualitative assessment provided additional accuracy in comparison to qualitative assessment alone. An interval between surgery and F-18-FDG PET/CT of <1month was associated with a sharp increase in false test results.
引用
收藏
页码:999 / 1008
页数:10
相关论文
共 50 条
  • [41] Reply to: The diagnostic accuracy of 18F-FDG PET in cutaneous malignant melanoma
    Delgado-Bolton, Roberto C.
    Jimenez-Requena, Felisa
    Fernandez-Perez, Cristina
    Gambhir, Sanjiv S.
    Schwimmer, Judy
    Perez-Vazquez, Jose M.
    Carreras-Delgado, Jose L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (07) : 1436 - 1437
  • [42] Reply to: The diagnostic accuracy of 18F-FDG PET in cutaneous malignant melanoma
    Roberto C. Delgado-Bolton
    Felisa Jiménez-Requena
    Cristina Fernández-Pérez
    Sanjiv S. Gambhir
    Judy Schwimmer
    José M. Pérez-Vázquez
    José L. Carreras-Delgado
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 1436 - 1437
  • [43] Cosmetic-Related Changes on 18F-FDG PET/CT
    Ho, Linh
    Seto, John
    Vincent Ngo
    Vuu, Harvard
    Wassef, Heidi
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (06) : E150 - E153
  • [44] The Performance of 18F-FDG PET and 18F-FDG PET/CT in Detection of Carcinoma of Unknown Primary
    Dong, M.
    Zhao, K.
    Zhao, J.
    Guan, Y.
    Liu, Z.
    Ruan, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S275 - S275
  • [45] Diagnostic Value of Increased [18F]FDG Uptake in Locoregional Lymph Nodes on PET/CT in Patients with Suspected Fracture-Related Infection
    Bosch, Paul
    Glaudemans, Andor W. J. M.
    de Vries, Jean-Paul P. M.
    van Snick, Johannes H.
    Lemans, Justin V. C.
    van den Kieboom, Janna
    Hobbelink, Monique G. G.
    Govaert, Geertje A. M.
    Ijpma, Frank F. A.
    DIAGNOSTICS, 2025, 15 (05)
  • [46] 18F-FDG PET and 18F-FDG PET/CT for Assessing Response to Therapy in Esophageal Cancer
    Krause, Bernd J.
    Herrmann, Ken
    Wieder, Hinrich
    zum Bueschenfelde, Christian Meyer
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 89S - 96S
  • [47] Whole-Body 18F-FDG PET and 18F-FDG PET/CT in Patients with Suspected Paraneoplastic Syndrome: A Systematic Review and Meta-Analysis of Diagnostic Accuracy
    Sheikhbahaei, Sara
    Marcus, Charles V.
    Fragomeni, Roberto S.
    Rowe, Steven P.
    Javadi, Mehrbod S.
    Solnes, Lilja B.
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (07) : 1031 - 1036
  • [48] 18F-FDG PET/MRI versus 18F-FDG PET/CT for the diagnosis of pituitary adenoma
    Wang, Hao
    Zhao, Xiaobin
    Zang, Jie
    Zhu, Zhaohui
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [49] Diagnostic Accuracy of Combined PET/CT with MRI, 18F-FDG PET/MRI, and 18F-FDG PET/CT in Patients with Oropharyngeal and Hypopharyngeal Squamous Cell Carcinoma: A Systematic Review and Meta-Analysis
    Kave, Mania
    Sadegi, Kambiz
    Parooie, Fateme
    Salarzaei, Morteza
    CONTRAST MEDIA & MOLECULAR IMAGING, 2021, 2021
  • [50] Diagnosing polymyalgia rheumatica on 18F-FDG PET/CT: typical uptake patterns
    Yuge, Shunsuke
    Nakatani, Koya
    Yoshino, Kumiko
    Koyama, Takashi
    ANNALS OF NUCLEAR MEDICINE, 2018, 32 (08) : 573 - 577